HomeMy WebLinkAboutPermit Building 1993-2-1
. .-
COMMERCIAL/INDUSTRIAL SP~'NGFIELD~OB NUMBER q~Dld)
PERMIT APPLICATION ~
INSPECTION LINE: 726-3769
225 Fifth Street, Springfield, Oregon 97477 ~ OFFICE: 726.3759
LOCATION OF PROPOSED WOR"'- 0J ()q,~ P. hr\ffiQ ~ J\,'N"\ ~,[Xl1i _> ~II~.
ASSESSORS MAP' 17 ()~ TAX LOT: ~. -, :=--. -\ \ \ \.---,_
<.2-
~
OWNER: '- lq}.+C\ ~ ~lLQ C)fj - ~HpNE, liAlo-~C)~
ADDRE~~' 14{~ h~ ....IJ [AJ ['.9\/.1 () n J I i~~ l~ _
C1TY\ -\~o 01 ~\ 01('( rJ/' STATE: (\LJLJ..~DY\ ZIP: L1lCX'~
DESC~IP}\ON OF WORK \)C)QI) -t\()'f\O V ,( \r{i 0 ~
NEW \j) REMODEL ADDITION DEMOLISH OTH~
I
VALUE:~ f':[()
~- J
NAM7> /.,J ~ ADDRESS PHOI}l
ARCHITECT$\l~nyt tJ~\J\YCHIf1, \S3~8...UdJ~ d44-1Sn
OON~ -
CONTRACT9R NA~E ADDRESS CONTRACTO DJ EXPIRES PHONE
GENERAl' l~ ~V
PLUMBIN'"
MECHANICA"
ELECTRICA' .
~-5t1.
I I MECHANICAL
FEE CHARGE-l I Nn I
/.:S /~~. 1 Furnace/burner & vent
? <100,000 BTUs
I I Furnace/burner & vent
> 100.000 BTUs
2s:--1 I Floor furnace and vent
1 ~ ....1 1 Suspended wall or floor
mounted unit heater
I /?s:--I I Appliance Vent
separate
1 /tP,-1 I Stationaryevap.
cooler
1 I I '7 Vent Fan/Single
duct
1 1 1 Vent System apart
from AC or htg.
1 I Mechanical exhaust
hood and duct
1 I
I I Permit Issuance
$1ft'- ....1 1 TOTAL PERMIT
..0
PLUMBING
NO,
/9 Single Fixture
Relocated Bldg.
Inew fix. addtl)
'-"'" .- Water Service
~
J
"'~6[)GY
~ ..." I
I
I
I
1
1
"7 -.::> 1
I
1
1
$10,00 1
3~ -"'I
........-
'~
Sanitary Sewer
/~ft.
Storm Sewer
/"'~&Ht.
/
Backflow Device
~
TOTAL PERMIT
QUAD AREA: ,j :0 ,~'JQ)
- OFFICE USE -
LAND USF ...:3?J'C[)
HANDICAP ACCESS'
. OF BLDG""
. OF UNIT""
FLOOD PLAIN:
ZONING: .::.-sLL
OCCY GROUP'
. OF STORIE""
CONSTR. TYpo.
HEAT SOURC.'
LIGHTING POWER BUDGET:
WATER HEATER'
SQ, FTG MAIN
SQ, FT.
/J? ~~
X
$/SQ, FT,
~~ 05'$
VALUE
o/".8~.6""P
SQ, FTG ACCES'" X
SQ, FTG OTHER i9'1v~ 2>V'9~x
,
/,~
~.?_ 0/'/6
TOTAL VALUE OF PROJECT
:522. ~A6
PLAN CHECK FEE
fi\4.<3\
RCPP 113-'\\
DAnd). f. q,--Cj BY~/:f'O_')
y'~. __ I DEMOLITION I
1 BUILDING PERMIT I
15% State I
Surchar(1e
[ MECHANIC~;
15% State
Surcharae .
I~~~ I
/z'9'9. ~~ PLUMBI~9-,,..
d L:J 5% State'
67 - 7''' Surcha'Qe
IP.p", I FENCE
"1"'J.""" VAUJ~ $
SIDEWALK
/.9~
:2 ~9: C>4
CURB CUT
j
, ,- I
// . #
1
/#:>~~~T SUBTOTAL '7"",,",, "" 1
FT. ~~G~.H'7'PERMITS ,#o'vl&'>"",
FT ?~""'c!'io::r ~mt~~MENT I fJ/6;;?.i'r1-1
/I, /i'6r.;i.~
'- ..' I ~~-.~. ;?-~7~. ~
--' - TOTALP~RMIT FEES :/.5 '7,Q~ 5~
EXCLUDING ELECTRICAl -.... C? /, (
::Z;;Z. ot>
~A:.
/,
~. . ,.
.. .
REQUIRED INSPECTIONS
<
It is the responsibility of the permit holder to see that all Inspections are made at the proper time. To request an inspection, call
726.3769 (recorder), stale your City designated job number, job address, type of inspection requested and when you will be ready
for inspection. Requests received before 7:00 a.m. will be made the same working day, requests made after 7:00 a.m. will be made
the following work day.
SITE INSPECTION: To be
made after excavation, but
prior to setup of forms.
v
UNDERSLAB PLUMBING,
ELECTRICAL &
MECHANICAL: To be made
before any work Is covered.
V ROUGH PLUMBING,
ELECTRICAL &
MECHANICAL: No work is to
be covered until these
inspections have been made
and approved.
x
ATTIC DRAFT STOPS,.a--
ox
PAVING: After gravel is in
place but prior to placing
asphalt or concrete.
'i
FOOTINGS & FOUNDATIONS:
To be made after trenches are
excavated and forms are
erected, all steel in place, but
prior to placing concrete.
t3ttft=fi:-..;;~ .....;.....~
FIREPLACE: Prior to placing
facing materials and before
framing inspection.
x
FRAMING: To be made after
the roof, all framing, fire
blocking and bracing are in
place and all pipes, chimneys
and vents are complete and
the rough electrical, plumbing
and mechanical are approved.
SPECIAL INSPECTIONS: In accordance
Section 306 of the State Specialty Code
a special inspector shall be employed
by the Ownerl Contractor during
construction of the following work. A
copy of the special testing reports shall
be furnished to the Building Division.
STRUCTURAL CONCRETE: In
excess of 2500 P.S,1. (306 a,1)
STRUCTURAL WELDS:, ,
Performed on the job, (2722 I)
HIGH STRENGTH BOLTING:
During all bolt installation and
tightening operations. (306
a,6)
SPRAYED ON
FIREPROOFING: U.BG,
Standards 43.8.
SPECIAL GRADING,
EXCAVATION AND FILLING:
During earthwork, (306 a,11 &
Chapter 29)
GLU-LAM BEAMS: Inspection
Certificate by an approved
agency, furnished to the City's
Building Division before
beams are placed, (2501 U,BG,
STDS, 25-10,11),
STRUCTURAL MASONRY: (306
a,7)
~p~"", W,r..v
Eh""""~ y~ P/V,
#;5' .'~r- _.t ":->----"
h,.,,/~,V~,/~/ ~~ t.
. . "In addition to the inspec-
tions specified, the Building
Official may make or require
other inspections of any
construction work to ensure
compliance with the Building,
City or Development Code.
--.:::,----------
Y SITE PLAN REVIEW BOARD: Must be requested 2 days in advance
of the date you wish inspection. All project conditions such as
landscaping, parking lot striping, etc. must be completed before
requesting this Inspection.
0/ FINAL BUILDING: Requested after the final plumbing, electrical,
mechanical and Fire Department inspections are made and
approved. No occupancy of the premises can be made until a
V Certificate of Occupancy has been issued by the Building Division
/" FINAL FIRE DEPARTMENT and posted on the premises,
AD1JONALcq\~:EN!S: -~ ~/T 7/L~ _-5:------ /~~V2F""AI';8_J -' /'!2..,~:;:
\0 )R~--, q,Q ,01' IZ\- 7€Y~JS!:> ~ h-.-~~
V U[)}\1I0 ~ - 6 \\~D~ 'd..} t SL..- "~~" ~~ :?~~~=--
, PLANS REVIEWED BY / z...~~~~-"""7 DATE ?~~
, /' /' ' . .,'/ -
A
I
CONCRETE SLAB: To be
made after all Inslab building
service equipment, conduit,
piping, accessories and other
ancillary equipment items are
in place but before any
concrete is placed.
.x
INSULATION & VAPOR
8ARRIER: To be made alter all
Insulation and required vapor
barriers are in place but
before any lath or gypsum
board interior wall covering Is
applied,
By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information
herein Is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances
of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY
will be made of any structure without permission of the Building Safety Division. I further certify that only contractors and employees
who are in compliance with ORS 701.055 will be used on this project.
I further agree to ensure that all required inspections are requested at the proper time, that project address Is readable from the
street, that the permit card Is located at the front of the propertY,and the approved set of plans will remain on the site at all
times during construction.
fr
UNDERGROUND: Plumbing,
electrical, gas, sanitary sewer,
storm sewer, water and
drainage lines. To be made
prior to covering or filling
trenches.
UNDERFLOOR: Plumbing,
electrical, mechanical. To be
made prior to installation of
floor insulation, decking or
floor sheathing.
POST & BEAM: To be made
prior to Installation of floor
insulation, decking or floor
sheathing,
FLOOR INSULATION &
VAPOR 8ARRIERS: To be
made prior to installation of
decking or floor sheathing.
ROOF SHEATHING AND
NAiliNG: Prior to Installing
any roof coverl ng.
MASONRY: Steel location,
bond beams grouting or
verticals In accordance with
UBC 2415,
A
J<
j(
FINAL PLUMBING
FINAL ELECTRICAL
, FINAL MECHANICAL
Signature ~ -,- .J"-.--<
x
FIRE & SEPARATION WALL:
Located and constructed
according to plans.
;(
LATH AND/OR GYPSUM
BOARD: To be made after all
lathing and gypsum board,
Interior and exterior, Is In
place but before any
plastering is applied or before
gypsum board joints and
fasteners are taped and
~;o"o~
,,-,
SIDEWALK & DRIVEWA .
Required for all concrete
paving within street right 0
way, to be made after all
excavating complete and for
work and sub.base material i
place.
CUR8 AND APPROACH
APRONS: After forms are
erected but prior to placing
concrete.
VALIDATION:'
RECEIPT #,
AMOUNT RECEIVED:
~b~~~SY
,.~ .... -- _...,-
-'- --".
Date
r-- '-'r -97
DATE PAID:
RECEIVED BY:
05'- ::? Zr? 3-
d--~,.
7'
.
..
_JOB NO. Cj?OI2-D
,
CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE
WORKSHEET
(COMMERCIAL &. RESIDENTIAL)
-NAME OR COMPANY: l/eL--rA. c.oL-L-EhEo
LOCATION: ""?(,"I':7 6. &AME:. FAfl:.M 12i:>.
IIO~Ic;,oO - I\I~ i tll~
DEVELOPf1ENT TYP!::: a: NeYJ Vor A-rll?t.JPd~ (O/JI..I.P..{"e:.
BUILDING SIZE: /o'tJV slt
1. STORM DRAINAG~
LOT S IZf
SQ. Ft.
IMPERVIOUS SQ. FT.
4'? ,t)OO
,
X $0.192 PER SQ. FT.
c: ~2.S~ "2kc;,?-;~
---- ---
2. SANITARY SEWER-CITY
NO. OF PFU'S
(See Reverse)
4'1
X $39.78 PER PFU
c;/"ItH~ ltfLf-'(t];.
~
3. TRANSPORTATION
CDPe. o;.+D J"1f.(f4IHM. Co~ : l.ol;o.I(,&S1<
NO OF UNITS X TRIP RATE X COST PER TRIP
10, ll''6
X /. Db'!- X $401. 05
Co.f(P'fZ~ t./b:-t"lo~
-- --
X
X
X $401.05
$
4. ADMINISTRATIVE FEES
BASE CHARGE (SUBTOTAL ABOVE) X .05
~
----------
TOTAL.CITY SDC $1'5?tto~E
40
1'fZ.-
5. SANITARY SEWER-MWMC
NO. OF PFU'S 4'\ x $13.62 PER PFU + $10 MWMC ADMIN. FEE $ ("11~
(Use PFU Total From Item 2 Above)
, I
$ }./.A. It
r-:~_ ~ 61,1-
TOTAL-MWMC SDC~!>.!__)
(Pe-
TOTAL SDC $ 1f4'2-f., 1,-
MWMC CREDIT IF APPLICABLE (SEE REVERSE)
0_ ~L'Jc.
. -(] Kip Burdick
SDC Coordinator
~ \\))\0'\'),'2:5
G~ 5t~qD,3<B
2/'-1/1';
5'25'~
--------
FIXTURE UNIT CAttLA TION TABLE: Numbe~ of Ne.es X Unit Equivalent = Fixture ~~is'(NO
For remodels, calculate only the NET additional fixtures) ,
FIXTURE TYPE
NUMBER OF
NEW FIXTURES
UNIT FIXTURE
EQUIVALENT UNITS
Balhtub........ ....... ....... ...... .............. .............. .... ..........
Drinking Fountain. ..:. .... ..... .... ....... .....:... ..... ..... .........
Floor Drain... ........ ....:....... ::........ ...............................
Interceptors For Grease/Oil/Solids/Etc.................
Interceptors For Sand/Auto Wash/Etc..................
Laund ry Tub /Clotheswasher..... ... ....... ....... ..... ........
Clotheswasher - 3. Or More.................,;..................
Mobile Home Park Trap (1 Per Trailer)..................
Receptor For Refrigerator fWater Station/Etc........
Receptor For Commercial Sink/Dishwasher /Elc..
Shower, Single Stall.................................................
Shower, Gang..........................................................
Sink, Bar, CommerciaL............................................
Urinal, StallfWall.......................................................
Wash Basin/Lavatory, Single..................................
Water Closet, Public Installation.............................
Water Closet, Private...............................................
Miscellaneous:
\
1-
Ca
r..
2
1 \
2
3'
6
2
6
6
1
3
2
1/Head
2 ~
2 '""
1 (,
6 "Jf..
4
TOTAL FIXTURE UNITS
=
I.\-q
CREDIT CALCULATION TABLE:
calculate credits separates.
II A:ne::ed-
I
Based on assessed value. If improvements occurred after annexation date in t
Rate per $1,000
Assessed Value
Year
Annexed
Rate per $1,000
Assessed Value
1979 or before
1980
19B1
1982
1983
1984
$2.83
2.76
2.71
2.60
2.46
2.33
1985
1986
19B7
19B8
1989
1990
1991
$2.16
1.90
1.60
0.25
0.87
0.50
0.16
Improvement (if after annexation date)
X $ =
(Rate X Assessed Value)
X $ =
(Rate X Assessed Value)
CREDIT TOTAL = $
-
Credit for Parcel or Land Only If Applicable
-
tJ.A
RUNOFF COEFFICIENTS FOR STORM DRAINAGE
ResidentiaL...... ..... ..... ......... ............................ 0.4
Commerci'~L......,............................................. 0.9
Industrial................... ..... ....... ....... ......... ............ 0.45
GovernmentaL................................................. 0.5
IMPERVIOUS AREA ,: TOTAL LOT SIZE X RUNOFF COEFFICIENT