Loading...
HomeMy WebLinkAboutPermit Correspondence 2007-2-4 ~ anchor scientific inc. 80x j,~ l:)";u ll...~ :.1rJ S';:h(, e~o.floQ~ C-.-135"L 9S;J...;7;i-r115. FAX Ch2 .173G(JG:). w~'JI,'.'_:1!lc!wr~c,('nllli(; cern Eco-Float Model G Dr.scription The Eco.t1oat is a mercury.tree tloal switch for controlling liquid levels in a I'ariety of applications. A snap-action switch is activated by a steel ball rolling back and forth within a switching tube in a plastic ftaa1 houeing. There is a minimum differential between "on- and .off" 01 approximately 3.5 inches. Greate, differentials can be achieved when the pipe mounted or externally weighted mounting styles are used. Various lengths of cable and circuit configurations are available and in stock. Features . Mercury Free . Variety of Mounting Styles . Variety of Circuit Configurations . Installation Easy . Differertialln One Float . Replaces Diaphragm and Mercury Switches ;.\!.;phcr.tions Th. Eco.Float can be used in a variety 01 liquid level monitoring applications including surrps, sewage ejectors. septic tanks. vauhs, lift stations, a,d tanks. Eco.Fioats are ruggedly constructed oi cor. nsion resistant materials. enabling them 10 be used in a variety 01 different liquids. Some applications are subject to additional requirements described iil the National Electric Code. Specifications Cabie Float Housing Electrical Ratings Clamp External Weight Temp. Limit Form G1 4/96 18-2 or 18.3 SJO W/A, 60 C., 41 x 34 stranding dia. - .29(18-2); .31 (1 8.3) Polypropylene Dim: 3.00 x 4.25 7A. @ 115 VAC; 3.5A @ 230VAC Polypropylene, (Morlel GP) Lead, 300 series st~inle"~ steel (Model GSE) 1400 F Model GSE Ordering Inform.ltion Specify: Model Mounting Style Cable Length ~E (external weight'Pl' SI (intemal weight) P (pipe mounted) ~". 1 0, 15, 20, 30, 40, 5~ Custom lengths avail~e NO (normally open'i/r NC (normally closed) NONC (normally openl normally closed) Circuit Configuration Example GSI 20NO - Eco-Float, suspended internal WI. 20', normally open contacts. 2 \\Ire FIoal- N.o. 3 VII... Float. NONe Ls ..""""" .........., - =~....4., -t .... 2 \\Ire Float. N.C. ..... (~- ...... SlOW Cable is an extremely lightweight and flexible cable Page I of2 DELeo WIRE AND CABLE cageCOde-08BRI L!MITED . I Duns # 879295228 Smce 1974 ...... ThmkDel~~^ ~~ 1-800-714-WIRE (9473) " I _. - RtQUt51 A QUOTE I 'lie ~J(JW Cable and SJO Portable Power and Control Cable ( . ) Required Field Your Name* I Company Name* I Email* I Phone* I Cable Type* I Gauge Size (AWG)* I # of Conductors* I Quantity in Feet* I Cpmments '~'I No Cut Charge . Same Day. Shipments IYIJ.JLSJOW C':eble from Delco Wire is an extremely lightweight and flexible cable commonly used for small appliances, motors and portable tools and equipment feir both Indoor and outdoor use. It's fine stranding makes it easy to strip and coil. Best used in environments where oUs, flames, grease and solvents are prevalent. .18 AWG. - Strandi~ I Bare CODDer - Get Quote Nom. Insulation Thickness (Inches) ,030" .030" ,030" Construction Conductor: Insulation: Cabling: Jacket: Color Code: Temperature: Voltage: Applications: ,<::I, lI['equiil!t;QQllteB!l Approvals: PIN 66202 66203 66204 I , # Of Cond, - Stranded soft"drawn bare copper IS AWG. 16 AWG 14 AWr, 12 AWl, 10 AWG - Thermoset ~ - Color coded multi-conductor '-fail resistant thermoset compound 1-IBlack, white, green, red. 1-190oC 1-1300 Volts - Portable tools and equipment Small appliances Motors Environments exposed to oils, solvents, flame, and grease Indoor and outdoor use - MSHA approved, UL 62, OSHA acceptable UL & sunlight Weather and water resistant 2 3 4 Nom. 0,0. (Inches) ,295" .320" .355" 10 56 10 72 7 96 Ampacily Lbs, I Ratings M' Sack to T@ 16 AWG - Strandi'1r Bare Co Doer - Get Quote I I Nom. Insulation I http://www.delcowireus.comltype_sjow_cable.php 1/24/2008 "" '" 'fl! -~ The A 1 OOOi Submersible Level Transducer is the industry's most highly engineered and advanced submersible level transmitter for the measurement of liquids containing high amounts of solids such as raw sewagelwastewater. The unit works equally well in potable water applications. The robustness and high reliability of the A 1 OOOi is based on its maintenance free design and simplicity of operation allowing it to operate in harsh environments. The unit is unaffected by turbulence, foaming, false echoing, solids build up, and atmospheric changes that often cause other level transmitter technologies to fail. A selection of pressure ranges is available to fit most wet well level/pressure measurement applications from high accuracy weir level/flow rate measurement to the deepest of wet wells and storage tanks. Several mounting options are available including vessel, pipe, fixed and suspension kits. THEORY OF OPERATION I . . The A 1 OOOi utilizes pressure, the most reliable means to measure liquid level. The sensor assembly is mounted at a low point (fixed or suspended) within the liquid media and uses a sensing diaphragm to measure the hydrostatic head- pressure. The pressure produced is proportional to the height of the liquid above the sensing diaphragm. The protruding (no cavity) flexible. Teflon@ coated Buna-N diaphragm uses a liquid fill to transfer the external diaphragm pressure to a stable and accurate gauge pressure type piezoresistive sensor. The transducer uses the loop power excitation source (9-30VDC) and converts the pressure to a proportional (4-20mA) electrical signal. The transducer is barometrically compensated via a rigid breather tube connected to a panel mounted seaied breather system. j I I SIEMENS APPLICATIONS Wastewater Sewage lift station wet wells Headworks Combined Sewer Overflow (CSO) Sequencing Batch Reactors (SBR) Lagoons/Ponds, Lakes & Rivers Equalization Basins Weir Flow Measurement Contact Tanks Sumps Water Raw Water Intake Level Filter Water Levels Clearwells Backflush Decant Tanks Above or Below Ground Storage Tanks Standpipes I I =- ,-""",~/~ """'""";^~....,..." _.'to'. ,..,.."',.,... -- - - . - -- - - - " .. Housing '-Cable I Atmosphere Ventilation '''MmTrrting I Exposed Materials I:Semlr;!gM~_!l I Power Required 316 Cast Stainless Steel, Teflon'" Coated - HeaYY""dcrtY'P61~;\ilerre"With'Ventiabe.ShieIHed'11l.AWG'Ci5ii'dUctors No Maintenance Sealed Breather System Equalizes Atmospheric Pressure '-SUsjieiiSiOriCaOle"Mount or 1"'12:5'4cmn';pe'Molint I 316 Cast Stainless Steel, Tetlon'" Coated, PVC, Synthetic Rubber and Urethane 1~9.:LaY~r~p.!aP!11"grn..yVj1!tre.!!?fi!.a'iicl Buna.N~Mare.irn1 I 9 - 30 VDC (7S0 ohm load @ 24VDC) " J , I"Signal-Output 14'='2'dmli ,..-.' FM and CSA Intrinsically Safe Class I, Div. 1, Groups A,B,C,D with ~~~.(2J~~a!I;i~L tit-"J;-;'Ii;;"O~',*.li.If'SC1I~..'f'Y<. I-AcC"ura~cv . Fu Sea e Wit 'ong erm - _ ta I It)' 0 . - 0' u ca e per ear I . Pressure langes j1.5PSI to 30 p~(o:14~r to )~l-Ba~ (Consult factory for ranges over 30 PSI (2.1 Bar)) I Max Over 1-1:S'PSr(0~j'Barr8X'FlifI.sCale S.O PSI (0.3 Bar) 4X Full Scale Pressure Range 15 PSI & 30 PSI (1.0 Bar & 2.1 Bar) 2X Full Scale j-r:;'mper.'ure I -40 to + 18S'F (-40 to 8S'C) (liquid must remain fluid) Ranqe I A 1 OOOi Sensors 1-1'.;S'PSI'(0~'8ar).4'20tnA"O.. OtpUt .. .6012950011 _. _(D.:.3d5.1!.(O~l.of-waterl. .. i 5 PSI (0.3 Bar) 4-20mA Output (0-11.5 ft (0-3.S m) of water) .....;1)J129S001~ '-15'PSI'(1:0'Bar)"4'20mWOutPUt,-6D'f29S0b13 I _(0,3~.7.ftSO.;J.9'~..P1),pf.water)~ .:::,,:,, I 30 PSI (2. { ~arl4-~6mA butput (0-69.3 ft (0-21.1 m Jot 'I 6012950014 ,. water) Consult Factory For Ranges Over 30 PSI . I ~_ _ _ '-Rousmgfcalile lissemoly _ r '-, I A iooo Housing/Cable Sub-Assembly 20ft (6.1 m~)6012640002 I L ::::-=J ",._) I:A1000::i3ousl/i'mc:a0li[;$uMssemlili::3O'l:U9:-.t;;m -6M26J\0003= t COMPLETE CONTROL C~PABILlTIES , Al000 Housing/Cable Sub-Assembly 40ft (12.2 m) 6012640004 r.... '~100Qli~sl.ii'91CiiIiI~~~selJ)!iJf,60fa!!l'm) -6D1'2~0006""" Siemens Water Technologies offers a single, I AlOOO Housingfcable Sub-Assemb(y1iOit /24.Q I 6012M0008 i high-quality source for everything from simple Al000 HouSlI\""i~IJI~U1i-'AmiiiOl\Clbbr(::r:s~ 1"b0126~0010- level sensors to telemetry systems involving g~ sselI1 1. t!.[W! complex system control engineering and A 1000 Housing/Cable Sub-Assembly Custom Lengt I 60126400XX software. Based in Vadnais Heights, Minnesota, (XX equalr Il!IC'ber of feet) Control Systems is part of the Siemens Water I Mounting Harlfware anlfi\ccessories Technologies leading global provider of , 8100 9G CLS Stainless Steel Pipe Mountinjl Clamps I 6011340001 industrial, municipal and residential water and ... "re' -~~'-~iii'-'-i'lJ!\ _. -.." ,.-.' .-- wastewater treatment systems, products and Cab e ~uspenSlon Mounling .'peew,t out SS calile, 6014180001 services. As a major manufacturer/integrator I 8reather Assembl Kit (Re uired for all Al000i sensors) I 60-12880001 product lines In the areas of SCADA ~nd y q telemetry, power equipment mtegratlon, 'Terminal Connection (Junction) Box with Built.in I 6012910002 automation and measurement, Control Systems Breather Assembly ,"', ' , is uniquely positioned to provide cost effective, I~BmtI'ier"AssemtiIYKif'(requ;~ea~with"A1DOOi)'Dua'I I 6012880002 comprehensive solutions for water, wastewater breather baqs (2) for over 8S (25.9 m) and process control and telemetry applications,~-, -- -- ----- --.. ----- The information providt!'d in this literature cont.ins merely 9l'rlt"f.1 descriptions or ch.riClerisliu of perl~nce which in actual aw of use do not always apply.s dt'SCri~ 01' which """ycNinge.s .. result 01 fu~ deYelopmenl 01 the products. An obligation 10 ~ t.... respectiw char;lCtl!riuics shall only exist jf expreuly 'gr~ in the terms 01 the contract. Teflon is I registered trademark of E.1. du Pool de Nemoors and ComPlny. Siemens Water Technologies 1239 Willow uke Boulevard Vadnais Heights. MN 5S110 800.224.9474 phone 651.766.2700 phone 651.766.2701 fa~ PrinledinU.5-A. CS.A1Kidr-D5-0407 Cl2007 Siemens Waler Technologies Corp. Subject to change without prior not;ce. I Project Project ID Created by Pas ,no Hayden Homes. Jasper Meadows Pump Station Spec 11347. Submersible Pumps Elaine Stone. APSCO INC. Data sheet: Motor data -- 66XG ~tor manufacturer Design ace. standard Se~ce factor Degree of protection Insulation class Starting mode No. starts / h Coolant temperature iii'-torcasin ~ n e KSB Rated \oOltage NEMA MGl Design B Rated frequency 1.15 Rated HP(D.D.L)orVFD IP 68 Rated current F Nominal speed Direct NEMAcode letter 30 Starting to rated current < / = 104 OF (40 .C) Starting current Grey cast iron EN-JL 1040 (A48 Class 35) (FM, CSA) XP Class I, Div. 1, Groups C+D, T3 _ KRT F 80-250/66XG-S KSB bJ 2007-08-14 230 V 60 Hz 7.5 hp 22.8 A 1160 rpm H 5.8 132 A 200"'"' ~""~20~ Load P1 P2 eta cas phi I CRM.('j ~ fklJlt,,,, {p/.#1e. kW hp % A Il-S i'/ t./~f.J t15>ew.bl y 0 4/4 6.67 7.5 83.8 0.73 11.4 71. <r a...... M'J. 1<>.. cliA$1. 3/4 5.08 5.6 82.5 0.66 9.6 Pili/ , 'l".'^f' C+-D/ 2/4 3.51 3.7 .79.6 0.54 8.1 1/4 2.02 1.9 69.2 0.36 7.0 per Vl1aM.v. I v.d-<<.-~ 1 xAWG 13-12 Diameter 0.89..0.98 inch Diameter Waterproof synthetic rubber compound 15m Main cable Control cable Cable, outer sheath Cable length O.B. 0.7, 0.6,- 0.5;1 O.4j 0.3. 0.2, 0.1; 0', o 3 0:5 i ;:5 ....,...., 3.5 4 ...., 4.5 5 .,,' 5.5 6' . . 6~5 . . '., , . . "':5 . , 'B' , , B~5 ' , P2'lh~1 2 2.5 ~~J -' . ~o ~70 ~O ~50 ~O ~30 ~20 ~1O 'J KSB bJ . II m " r;j -~ II -~--~- II c'1M~ '7 #1_ W'lOWV? :.--------- Rubber Cable NSSHliu-J Technical data Short description Copper conductor, finely stranded class 5 to DIN VDE 0295 PROTOMONT rubber-sheathed cables NSSHOU are designed for the mobile connection of KSB submersible motor pumps from a cross section of 50 mm2. PROTOLON insulation Due to the many different and variable compositions of waste water, the cables must be installed In easily accessible places where they can be inspected without diffi,ulty. Rubber inner sheath PROTOFIRM outer sheath color: yellow When aggressive water or water of certain other compositions is involved, the chemical resistance of the cable must be checked in each individual case. These cables can be used Indoor I outdoor, in hazard areas, in locations exposed to fire hazards, in industrial and agricultural plants. Permissible temperature at oonductor Permissible temp. in case of short-circuit (up to 5 s) In addition, the general regulations of DIN VDE 0298-300 (HD 516) apply. Buming behaviour according to DIN EN 50265-2-1 UV, ozone and weather resistant Oil~reslstant acc. to DIN VDE 0473-811-2-1, Sedion 10 flexible Temp. during transport and handling: -25 to + 80.C 0,6/1kV: with green-yellow core _ _ _._._~~ Application with waterl no drinking water 221 I- RICHARDSON Bryan From: Sent: To: Cc: Subject: Seth [seth@kipcoinc.net] Tuesday, January 29, 2008 3:52 PM Irosenberger@ksbusa.com Roy Hankins; RICHARDSON Bryan Spam: Pump Wire info I am looking for eome information on the power chords of these pumps. We have two of them from you for the Jasper Meadows Pump Station in Springfield Oregon. The local inspector is asking me for this information. I thought you may be able to help me out. Please send anything you have Please reply ASAP as I need to get him something soon and no one else has been able to get me what I need SEWAGE PUMPS NO. 1 AND 2 TWO (2) KSB KRT F 80-250/66XG PUMPS c.I atA:;: 1) / V I UlI'lIwf e.+ D Seth Brown Kipco Inc. P 689-9265 F 689-9351 www.kipcoinc.net 1