HomeMy WebLinkAboutPermit Building 2002-5-17
..
,.
.
.
I Job# 02-00584-01 I
Page 1 of 2
TRANS#:Ol-0009128
DATE:MAY 17 2002
AMT RECD:2 $ 168.36
CHANGE:
CASHIER:061
225 Fifth Street
Springfield, OR 97477
CITY OF SPRINGFIELD, OREGON
RESIDENTIAL PERMIT
City Of Springfield
Community Services Division
Building Safety
Job Number: 02-00584-01
Office: 726-3759
Inspection Line: 726-3769
Location Of Proposed Site: 7275 Daisy St Spr
Assessors Map#: 17023534
Lot: Block: Addition:
Owner:
Tax Lot #: 03600
. Subdivision:
Aaron Bolkan
Phone Number: 541-746-0805
City/StatelZip: Springfield, OR 97478
Repair Value: $15,000
Address: 7275 Daisy Street
Scope Of Work: Single Family Residence
Contractor Type
General Contr
Quad Area:
# Of Units:
Constr. Type:
Water Heater:
Repair tree damage, Engr'ng OK'd per TM,051702
. Contractor
Registration #
4231
Expiration Date
11/19/2004
Phone
Ehlers Construction Inc
2066112 Roosevelt Blvd, EUgene, OR
97402-2536 N01\CE:_ _ 'JJ ~'lCP\RE If lHE WOR~
Office Usel':ll~ Pt.~I'I\1( ~~OER lHIS PERMII 10) 1\3.
Land Use: AU1H~~:~O OR IS MI&~Qg~cf.~Js~R
Zoning Code: CO~ 180 DAY PERIOlhccupancy Group: '
Bedrooms: AN Heat Source:
Range: Sq. Footage:
541-689-6177
To request an Inspection call the 24 hour recording at 726-3769, All Inspections requested before 7:00
a.m, will be made the same working day, inspections requested after 7:00 a.m, will be made the following
working day.
Construction Types:
Occupancy Groups:
# Of Buildings:
# Of Bedrooms:
Handicap Access? 0
,Area (Sq, Feet)
I Main: Accessory:
Framing
Fimil Building
Required Inspections , ':IoU tU
, . I W requIres , 't
I BUlldmq I '\ON',oreg~.n "" e Oregon UtilI ':I
. Prior to cover. AT \ t:1~ leS adopted b':l t\1 lies are set 10rt\1
- When all required Inspections have tieenVap~roved.and1~EPBMd\n!:!Jisrc6iiiPlg~1.
Notilicalloll :001'-001 0 t\1rOU\l1 0; the rules 0':1
, in OAR 952. a obtain CapleS e telephone
0090. YOUt~e ~enter. \Noteu:tft':l Notilication
calling Oregon II )
rnberlort\16. 800-332.-2344 .
nU ,..""tans 1-
Height (feet):
Proposed Units:
# Of Stories:
Current Units:
Census Code: Does not apply
Total:
I
.
.
Job# 02-00584-01
Paid On Recelpt#
Building
05/17/2002 9128
05/17/2002 9128
05/17/2002 9128
.
Page 2 of 2
Fee
Value/Quantity
Fee Amount
Building Permit
State Surcharge For Building Permit
8% Building Administrative Fee
Total Building
Grand Total
By signature, I state and agree that I have carefully examined the completed application and do
hereby certify that all information herein is true and correct, and I further certify that any and all work
performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of
the State of Oregon, I further state that only contractors and employees who are in compliance with
ORS 701,055 will be used on this project. I further agree to ensure that all required Inspections are
requested at the proper time, that the project address Is readable from the street, that the permit card
is located at the front of the property, and the approved set of plans will remain on the site at all times
during co~_ )) \ J
V~'-'---'?.L...- ,5--( I - D Z
Signature Date
15,000
$146.40
$10,25
$11,71
$168,36
$168.36
"i-. -':'-... .
.0
e81 Grover EngIDeeril..
P.O. Box 2956
Eugene, Oregon 97402
(541) 688-3020
May 14, 2002
Ehlers Construction
2066\1, Roosevelt Blvd.
Eugene, OR 97402
Re: Tree Dl1IIIlII!e at 7275 Daisv Street. Sorinqfield. OR . Job # 02094
As you requested, an inspection was performed at the above noted address on May 13, 2002 to examine
damage that has been exposed during the repair of the stick-framed roof system at the above noted
address. A falling tree struck the roof above the upstairs bedroom at the west end of the residence, At the
time of the inspection the gypsUm on the ceiling had been removed exposing the 2x8 rafters at 24" on
center, and the underside of the lx8 roof sheathing.
The damage to the house consisted of a puncture in the lx8 roof sheathing at the ridge. The impact also
caused the 4x ridge beam to split at the location of a hole drilled in it to run wiring for a light. Both the
damaged roof sheathing and ridge beam are to be replaced with materials of equivalent properties. The
2x8 rafters in this area did not suffered any visible crushing or splitting. However, existing rafters will
have to be scnbe cut in order install the new ridge beam. This notch is only reqwred on a few of the
rafters on the north side of the ridge, and does not decrease the strength of the rafter as installed. (see
attached calculation) A 24" section of2x4 is to be sistered onto the 2x8 at the location of the notch after
the new beam is in place. Simpson A34 clips are to be installed on the sides of the new beam connecting
it to each existing 2x8 rafter and new 2x4 section, to ensure proper transfer of verticalloliding to the
beam.
Damage not noted above that is discovered during the repair of the structure should be brought to the
attention of Owen Grover Engineering, P .C. Thank you for this opportunity to be of service, If you have
any questions please do not hesitate to call Kevin M, Peterson, P.E. at (541) 688-3020.
Very truly yours
Owen Grover P.E.
~ -irwen Grover Engi..ring P.C.
, 1050 Bethel Dr. Suite #04
Eugene, Oregon 97402
(541) 688-3020
, ~1D<<r1<e.~i--'I-
w.,. (11,5/.. )Ct-c)~ 7.~Of\-i
&PAH ~ 1:0.'-'-"
v.,- 15S~ '"
t1 ~ S-z+=, .. j:'i
:. 1", I-z. HI~,
\2AFn:ra.
w = z. (~') ~ 80 I'l.f
.1 '" '
":Sf".... t-l" -, - c> ",I..,..
'"
...,/. Z-Bo,
"1 ~ 44" "'I"(
.. Z-I<I<> ,..."..;.
GJENT
SHEETNU
CAlCUlATED BY
JOB'
A~'" 2:1.,,:>,...1'"
<;.~" ~.S 114'"
AI!-" S,5,>ol~
'5o(t = 5.8 I"';:'
~ I-lLr[i!--'?
e\
~b
r
oz.o;4'
'1F
DAlI
r:,-I~-c:>......
" 9.1 '
An ~ 0, 'Zt.. --'" I"t.'!o
3_e/ .
Di<f'-rH (! e.lt.o~l-'lo~"",.l, = /1.1;;" Z.';'"
, "
"r- 'Z. "'/e,