Loading...
HomeMy WebLinkAboutPermit Correspondence 2004-5-26 BATTS AND BLANKETS When installed in accordance with the man. ufacturer's recommendations, Knauf batts and blankets will provide the ful! R-value. F"';~"=;""'~~;gMIHIMUMiiil!'" /fffl;iV~:i~".,lff!~THi'CK'NESS'~ - To obtain a-n Installed insulation insulation resistance shauld nat be (R-Value) of: less than: I 1 1 I I I 1 I I I 1 -I R-8 2.50' I"R-18in a 5-.5" cavity. Conforms to ASTM C 665 and Federal Speofica.lion HH-I-521F. R.38HD R.38 R-30HD R.30 R.26 R-22 R.21HD R-t9 R-15HD R-13 R-tl to.25' t2.00' 8.25' to.OO' 9.00' , 6.50. 5.50' 6.25'" 3.50' 3.50' 3.50' 'I. JET S TREAM'" ATTIC CARD FIBER GLASS BLOWING INSULATION Ljez.O C.t L THERMAL PERFORMANCE (ATTIC APPLlCAil6N't r 0 1"\ --e...-e....- The slaled thermal resistance (R-value) is provided by installing in accordance with the manufacturer's instructions. the required number of bags per 1,000 sq. ft. of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at least the minimum thickness will result in lower insulation R-value. jIE;':7"'~':-/;;;:;;.~\;:;rtC~~:':"~~,$h'1:-~';-~~'€:",,:::;ii:~::_~M~IMU;I'fI~-_ :;;T_':----~-i-TMJNI",~M3< '~'-,":'-';;'_0_~-I_NIMUM;:: _ --~ ~lIitywAf~~g8AAsm;tw:j~~~~'COVERA-rif.~!:i~,' ~Jt~'w1i,G_HT~*'~~~7;~"!eKN~i$1i~ To obtain an The number of bagsl Contents of this bag . The weighllSF Installed insulation insulation resistance 1,000 SF of net area should not cover of installed insulation should not be' (R.Valuol of: should not be less than: more than: should not be less than: less than: R.60 31.7 31.5 SF .952LBS 19.75' R.50 25.8 38.7 SF .774 LBS 16.75' R-44 22.1 45.3 SF .663 LBS 14.75' R.38 19.0 52.7 SF .569 LBS 1300' R-30 t4.4 69.7 SF .43tLBS 10.25' R-26 t2.4 80.9 SF .37t L8S 9.00' R-22 to.4 95.8 SF .313 LBS 7.75' R.19 8.9 Ilt.8 SF .26B LBS 6.75' R-t3 6.1 t64.3SF .183LBS 4.75' R-lt 5.t 197.6 SF .152 LBS 4.00' Bag Weight-Nominal30 IDs., Minimum 291bs. This product conforms to the performance requirements of ASTM C 764, Type I, and cancelled Federal Specification HH-l-l030B, Type I, Class B. R-values are determined in accordance wilh C 587 and C518. , 'R" means resistance to heat now. The higher Ihe R-value, the greater the Insutation pcl'Ner, To gel the marked R-value. II IS essenlial thai lhe insulation be installed properly. ilvoudoilvourself,gelinstructionsandfollowthemcarefully_1nslructions do not come wilh Ihls package. EQUIPMENT REQUIRED To achieve labeled R-value, this product must be applied wittl a pneumatic blowing machine and a corrugated hose with a minimum .25" intemal corrugation, a mini. mum length of 150 ft. and a diameter of at least 3~ Coils in the hose should not be less than 36" in diameter. Acceptable material feed rate is 5-35 Ibs.lminute. Recommended feed rate is 15-25 Ibs.lminute. BUILDER'S INSULATION STATEMENT Batts and/or blankets have been installed in conformance with the above recom- mendations to provide a thermal resistance of. . ~~~~_'~-;;;;":RWAiijE'~~THICKHESS~' - -____ - --- --- . ,~-_,..,=--~.,;;,--,=~~j!.~A~-,..~",,~ Attic Area R- 5<t' at /3 Inches I Sloped Ceilings R. al Inches I Walls R- 7/ at , Inches Floors (over an unheated crawl space) R- 7_<::; al q' 3: ..Jnches Crawl Space Perimeter R- at Inches Date Installed .)' L !j( (') L/ Blown insulation has been installed in conformance ~the above reco~mendalions to provide an R-value of: R. ? l5 using / . 7 bags of this insulation to cover 9 ~ 7 _ square feet of area at a minimum thickness of / ~ inches. x/~~J;,~ IlnSUlatlOnconir:w.ior(slgnaIU~ t-- i; + ~/.( / /:. -e~r HA/7 ,- r",;..--, . I Company .; I Home Builder (signalure) I Company Date Date FRAMING ADJUSTMENT To compensate for framing members, the number of bags per 1,000 sq. ft. of area to be insulated should be as shown below. .- 1:;~~~j~I~:J~t~;:~~~:f;.s~~~~:"!er;4~~~~J~~~~il R-60 1 ~: . ::~ ! ::: 'I I ~ ~ I m I I ~ ~ I ~ I R-50 I 2,6 25.0 I 25.2 I I 2,8 24.6 I 25.0 I 2x4 21.5 I 21.7 R-44 ~6 ~.2 I ~.5 2,8 20.9 I .21.2 2,4 18.4 I 18.6 R-38 ~6 18.t I 18.4 2,B t7.B I 18.2 2x4 13.8 I 14.0 R.30 2,6 t3.5 ',I' " t3.8 2x8 13.3 13.6 ~4 tt.9 t2.0 R-26 ~6 t1.6 tl.8 2x8 11.3 11.6 2x4 9.9 10.1 R-22 2x6 9.7 9.9 2x8 9.4 9.7 ~4 8.5 8.6 R-t9 ~6 8.2 8.4 2x8 7.9 8.2 2x4 5.6 5.8 ~3 M ~ U ~8 5.1 5.4 2x4 4.6 4.7 R-l1 2x6 4.3 4.5 . 2x8 4.1 4.3 ',", k.AUt BW-AC-14 APR 2004 KNAUF INSULATION GmbH One Knauf Drive, SheJbyviJle, IN 46176 ; (~) 825-44Wext. 8300 FAX (317} 398.3675 'M'tW.KnaufUSA.com @2004 Knauf Insulation GmbH ~-- .