BATTS AND BLANKETS
FIBER GLASS BLOWING INSULATION
When Installed In accordance with the man
ufacturer 5 recommendations Knauf baUs
and blankets will provide the full R value
. MINIMUM
"-VALUE* THICKNESS
To obtain an InslaU@d insulation
insulation r@sislilncl!! should not be
(")of:. less than:
R 38 1200
R 30HO 825"
R 30 1000"
R 26 900"
R22 650"
R 21HD 550
R 19 625 **
R 15HO 350
R13 350"
R 11 350"
R8 250"
Bag Weight-Nomina! 28lbs Minimum 27 Ibs
HR 18ma S 5 cavity Conforms to ASTM C66Sand
FederalSpeclflCatlOnHH I 521F
EQUIPMENT REQUIRED
.
.
.
.
.
.
.
.
,
.
.
.
.
,
,
,
,
,
,
~
~~
THERMAL PERFORMANCE (ATTIC APPLICATIDN)
The stated thermal resistance (R value) IS prOVided by installing rn accordance wIth the manufacturer 5 instructions
the required number of bags per 1,000 sq ft of net area, at not less than the labeled minimum thickness Failure to
Install both the required number of bags and at least the minimum thickness Will result In lower insulation R value
It-VALUE.
To obtain an
insulatlOnrl!!sistancl!!
(It-valul!!) of:
lAGS !lEft
1,000 SQ. FT,
Thl!! numbl!!r of balS pl!!r
1,000511. ft. of nl!!tarl!!a
should not bl!! Il!!s.slhan:
378 265SF 1058lbs 2350"
R50 310 322SF 869lbs 2000"
R44 269 372SF 753lbs 1775
R 38 22 9 43 6 SF 642 lbs 15 50'
R30 179 559SF 501lbs 1250"
R26 155 646SF 433lbs 1100
R22 127 784SF 357lbs 925
R19 109 920SF 304lbs 800
R 13 76 1316SF 213lbs 575"
Rll 62 1613SF 174lbs 475'
1 ThiS proOllrt r_o!)lorms to th!! performance requirements of ASTM C 764 Type I and cancelled Federal SpeCification HH 11030B Type I
(l:ssB F values are determined In accordanc(' { thC6B7andC518 _
1* R mea1S resistance to heat flow The higher t'le R value the gre~ter tire insulating power Ask your seller for the fact sheet on R values
tf
,1
To achIeve labeled R value, thiS product must be applied With a pneumatic blow
Ing machme and a corrugated hose With a minimum 25 Internal corrugation, a
minimum length of 150 ft and a diameter of at least 3" COils In the hose should
not be less than 36" In diameter Acceptable matenal feed rate IS 5 35
lbs /mmute Recommended feed rate 1515 25lbs Imrnute
BUilDER'S INSULATION STATEMENT
Batts and/or blankets have been Installed In conrormance With the above recom
mendatlOns to prOVide a thermal resistance or
- f':-Value Thicknes~
Attic Area R :;nr at J{, Inches
I Sloped CeIlings R at Inches
I Walls R "2-1 at 6, Inches
I Floors (over an unheated crawl space) R 2...5 at g-;..b Inches
I Crawl Space Penmeter R at Inches
Datelnstalled37' - 0 L/
Blown insulation has been Instatted In'conrormance With the above
recomme;<'ons to prOVide an R val~e of R j' l?'" usong
"7 , bags ofthls insulation to cover I/? <'~quare feet
of ~rea-at a minimum thICkness or; / (.. .. InC~S
A1/~~~
rnsulatlonconrracior(slgna~/ / ....J~
r>:J /) / M oC__)-.M/J/J G/l/A r-
Company . -- - ..... - - .;.. Date
Home BUilder (signature)
I Company
BW AC 08 5/02
Oate
FRAMING ADJUSTMENT
To compensate for frammg members the number or bags per 1 000 sq ft of
ilrea to be Insulated should be as shown below
\\ JOIST
"-VALUE DIMENSIONS
R 60 2x6
2x8
2x4
R 50 2x6
2x8
2x4
R 44 2x6
2x8
2x4
R 38 2x6
2x8
2x4
R 30 2x6
2x8
2x4
R 26 2x6
2x8
2x4
R 22 2x6
2x8
2x4
R 19 2x6
2x8
2x4
R13 2x6
2x8
2x4
R 11 2x6
2x8
372
368
365
305
302
298
263
260
257
224
221
218
174
171
168
150
147
144
123
120
117
104
101
98
71
68
66
57
55
52
373
371
368
306
304
302 '
265
263
260
225
223
221
175
173
171
151 --..""'"
149
147
124
122
120
105
103
101
73
71
69
59
57
55
CLOSED CAVITY APPLICATION
(EXTERIOR SIDEWAll OR flOORED ATTICS)
Contact Knauf Fiber Glass for more informatIon
Knauf FIber Glass One Knauf DTlve ShelbYVllle IN 46176 (800) 825 4434