HomeMy WebLinkAboutPermit Building 2008-1-4
('0 _6(
l,vl
~ rI' 4J
~~
CITY 01' ~rKINGFIELD
Building/Combination Permit
PERMIT NO' COM2007-00795
ISSUED: 08/07/2007
APPLIED. 06/01/2007
EXPIRES: 07/04/2008
VALUE: $ 500,00000
Status
Issued
225 FIlth Street, Springfield, OR
541-726-3753 Pholle
541-726-3676 Fax
541-726-3769InspectlOlI Lme
SITE ADDRESS 3320 Gateway St
ASSESSOR'S PARCEL NO 1703222001700
Sprmgtield TYPE OF WORK Tenant Infill
TYPE OF USE Remodel
Commercial
PROJECT DESCRJPTION Tenant Improvement - Staples
Owner NEWGATE LLC
Address 840 BEL TLlNE RD STE 202
SPRINGFIELD OR 97477
Phone Number 541-284-0624
I CONTRACTOR INFORMATION I
Contractor Type
General
Electrical
Fife Contractor
Low Voltage Electrical
Mechamcal
Plumbmg
Contractor
MEGA PACIFIC CO
NEW WAY ELECTRIC INC
OMLID AND SWINNEY
INTEGRA TED ELECTRONIC SYSTEMS
MICHAEL GRIFFIN
RA YMIE JASON HOYT
License
63108
51088
62730
165599
150189
157734
Exp,rahon Date
01116/2008
06/27/2009
12/1512011
07/1312009
01123/2008
11/1712009
Phone
503-519-7564
541-686-2365
541-741-1775
541-485-4456
541-942-8339
541-689-4235
BUILDING INFORMATION I
# of Umts
Primary Occupancy Group
Secolldary Occupancy Group
Pnmary Construchon Type
Secondary ConstructJon Type
# of Bedrooms
B
M
IIIB
# of Stories
HeIght of Stl ucture
Type ot Heat
Water Type
Range Type
Energy Path
Sprinkled Buddmg
Lot SIZe
Sq Ft 1st Flool
Sq Ft 2nd Floor
Sq Ft Basemellt
Sq Ft GaragelCarport
Sq Ft Other
Occupant Load
579
nla
I DEVELOPMENT INFORMATION I
Frontyard Setback
SIde I Setback
SIde 2 Setback
Rearyard Setback
Solar Setbacks
Overlay Dlst
# Street Trees Rqd
Paved Drive Rqd
% of Lot Coverage
REQUIRED PARKING
Total
HandIcapped
Compact
, 1-
MI I L,;,;I'\III\..II~ v, V~V, I '...... . ...."1...... '"'''' . -.... .- -
follow rules adopted by the Oregd;I'UB/~ IMPROVEMIDN:f"!~E:
Street 1.w~Hl\GilllMPenter Those rules are ~~lIUfr,1 I ~I~ PERM$Td
In OAR 952-001-0010 through OAR 952-001- AUTHO ~"""~l!m.'PIRE IF THE WORK
Storm ~~O.AYl!lIl:mky obtam copies of the rules by GOMM RIZEBoUWWi.l1t~~I/i!ERMIT IS NOT
SpCClallnn:lll1tfpthe center. (Note' the telephone ENGEO OR IS ABANDON
number for the Oregon Utility Notification ANY 180 DAY PERIOD ED FOR
Notes Center Is HI00-332-2344).
Paee 1 of 5
Status
Issued
225 Flftb Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 InspectIOn Lme
DescriptIOn
Type of ConstructlOlI
Estimate
Estimate
Fee DescriptIOn
Plan RevIew CommlIndlPubhc
-Mechamcallssuance Fee-
+ 10% AdmmlStratJve Fee
+ 5% Technology Fee
+ 8% State Surcharge
BUlldmg PermIt
Fixture
Mmlmum/AdJustment Mechalllcal
Plan RevIew Fife & LIfe Safety
Vent Fan
+ 10% AdmllllstratJve Fee
FLS Safety Systems RevIew
+ 10% AdmmlStratlve Fee
+ 5% Technology Fee
+ 8% State Surcharge
Add, Alter, Extend Clrc Ea Add
Perm Serv/Fdr 200 amps or less
Perm Serv/Fdr 201 to 400 amps
Perm ServlFdr 401 to 600 amps
Total Amount PaId
IlIItlal RevIew
06/04/2007
Plannme RevIew
06/06/2007
Pubhc Works RevIew
06/06/2007
Structural RevIew
06/04/2007
CITY OF SPRINGFIELD.
Building/Combination Permit
PERMIT NO' COM2007-00795
ISSUED 08/07/2007
APPLIED: 06/01/2007
EXPIRES. 07/04/2008
VALUE. $ 500,000 00
I, ValuatIOn OescrmtlOn I
$ Per Sq Ft
or multlpher
$100
Square Footage
or BId Amount
500,000 00
Value
Date Calculated
Total Value of ProJect
$500,000 00
$500,000 00
06/0112007
FpP~, P'llrU
Amount PaId
Date PaId
ReceIpt N umbel
$1,21267
$10 00
$21067
$105 33
$16853
$1,86565
$19600
$33 00
$746.26
$12 00
$138 83
$1,388 25
$86 90
$43 45
$69 52
$354 00
$315 00
$75 00
$125 00
6/1107
817107
817107
817107
817107
817107
817107
817107
817107
817107
10/29/07
10/29/07
11/14/07
11114107
11114/07
11114/07
11114/07
11114/07
11114/07
2200700000000000889
2200700000000001258
2200700000000001258
2200700000000001258
2200700000000001258
2200700000000001258
2200700000000001258
2200700000000001258
2200700000000001258
2200700000000001258
2200700000000001645
2200700000000001645
1200700000000001398
1200700000000001398
1200700000000001398
1200700000000001398
1200700000000001398
1200700000000001398
1200700000000001398
$7,15606
I Plan Rev,ews I
06/0412007
APP LLH
06112/2007
APP EMM
06/19/2007
APP JHJ
Attached SDC Worksheet No New
SDC's (JHJ)
06/20/2007
WE JMP
ReceIved 6/6/2007 See attached
documents for 11 structural
comments faxed to Jack Knz
Paee 2 of5
_SPAINQE'11ill-D
WIi:. CITY OF SPRINGFIELD.
Building/Combination Permit
Status Issued PERMIT NO CO M2007 -00795
225 FIfth Street, Springfield, OR ISSUED. 08/07/2007
541-726-3753 Pbone APPLIED' 06/01/2007
541-726-3676 Fax EXPIRES. 07/04/2008
541-726-3769 InspectIOn Lllle VALUE. $ 500,000 00
SUB Review 06/0612007 06/20/2007 WE JF See aUached documents for Item 6
of JMP's structural comments
requestlllg the energy code forms
and mformatlOn
Fife Department Review 06/06/2007 07/05/2007 OK GRG See attached document for FIre
Department Plans RevIew
comments
Plan RevIew Comments 07/1312007 10 JMP WE Received Incomplete responses
to structural comments from Curt
Trolan Curt saId that Items 8 and 9
(contractors and valuatIOn) WIll be
dehvered later when they are
determllled
Plan RevIew Comments 07/24/2007 10 JMP WI ReceIved contractor and
valuatlOJI data from WhItney Boss
SUB Review 07/1312007 08/03/2007 APP JF JMP receIved energy code forms
from Curt Trolan and forwarded
them to Jack Foster at SUB
Structural RevIew 08/06/2007 08/06/2007 APP JMP Received finallllternal approval
ImtJal RevIew 09/05/2007 09/05/2007 APP LLH FIre Sprinkler System - Forwarded
to GIlbert Gordoll
Fife Departmellt RevIew 10/1 012007 10/1012007 OK GRG Plans RevIew SIX IIIch underground
fire hne stub up Job
#COM2007-00795 DeSIgner Bob
Colhns Contractor Omhd and
SWlllney Plans appear to meet code
reqUIrements
Paee 3 of 5
. _._~."~ till
~
*-
Status
Issued
CITY OF SPRINGFIELD.
Building/Combination Permit
PERMIT NO' COM2007-00795
ISSUED 08/07/2007
APPLIED: 06/0112007
EXPIRES: 07/04/2008
VALUE' $ 500,00000
225 FIfth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 InspectIOn LlIIe
FIre Deoartment RevIew
09/05/2007
1012712007
OK
GRG
Plans RevIew Sprinkler system for
Staples Job #COM2007-00795
DeSIgner Bob Colhn; Contractor
Omhd and Swmney
ThIs IS a grldded wet spnnkler
system wIth an antifreeze loop
protectlllg the south SIde front
parapet (Remote Area 3 LIght
Hazard 10 gpmlsq ft for 150 sq
ft ) and the nortb SIde truck loadlllg
dock canopy (Remote Area 4
Ordlllary Hazard Class II at 20
gpmlsq ft wIth 12 1l0wIIlg heads)
The mercantIle area bas two remote
are.! calculatIOns Remote Area liS
claSSIfied as au Ordmary Hazard
Class II, but uSlllg Tyco EC-25
Extended Coverage Area DenSIty
sprinkler heads resultlllg m a
calculatIOn of 425 gpmlsq ft over
2000 sq It from 2 lIIch br.lllch hues
Remote AI ea 2 conSIsts of a second
calculatIOn wIth 4 EC-25 heads
caked to 50 gpmlsq ft
The 6 lIIch riser has a Tyco Mode'
A V-I-300, DN150 (6 mch) alarm
check valve wltb an aSSOCiated
Model RC-1 Retard Chamber
lIIstead of tbe usual mamfold rISer
The plans state commodItIes are
expected to be various Class I
tbrough IV Items wIth a storage
helgbt not to exceed 12 feet
Plans appear to meet code
requlI ements
To Request an inspection call the 24 hour recordmg at 726-3769. All mspectJons requested before 7 00
a m WIll be made the same workmg day, mspectlOns requested after 7'00 a.m will be made the followmg
work day
I.R~~
Frammg InspectJon Prior to cover and after aliI ougb III IIlspectlons have been approved
Wall InsulatIOn Prior to cover
Paee 4 of5
CITY OF SPRINGFIELD
Building/Combination Permit
Status
Issued
PERMIT NO: COM2007-00795
ISSUED' 08/07/2007
APPLIED. 06/0112007
EXPIRES: 07/04/2008
VALUE: $ 500,00000
225 FIfth Street, Springfield, OR
541-726-3753 Pbone
541-726-3676 Fax
541-726-3769InspectlOlI Lme
Cellmg Insulation Prior to cover
Cellmg Grid After drywall approval but prior to cover
Fmal Fife Department After all reqUIrements of the Fife Department have been met
Fmal BUlldmg After all reqUIred mspectlOns have been requested and approved and the bUlldmg IS complete
Rough Plumbmg Prior to cover alld mcludmg reqUIred testmg
Fmal Plumbmg When all plumbmg work IS complete
Rough Mechamcal Prior to Cover
Fmal Mechamcal When all mecbamcal work IS complete
Rough ElectriC Prior to Cover
Fmal ElectriC Wben all electrical work IS complete
SUB InsulatJon Vapor Barrier To be called for at the same tJme as the SUB framlllg mspectlOn
SUB Fmal After all reqUIred energy mspectlOns have been requested and approved
SUB Mechamcal Followmg CIty Rougb MechamcalmspectlOn approval and prior to any cover
SUB Cellmg Grid Interior Llgbtlllg
SUB Exterior Llghtmg
ElectriC ServIce Approval reqUIred prior to utJhty company energIZIng servIce
Low Voltage Prior to cover
By SIgnature, I state alld agree, that I have carefully exammed the completed apphcatlOn and do hereby certIfy that all
mformatlon hereon IS true and correct, and I furtber certify tbat any and all work performed shall be done 1Il accordance WIth
the Ordmances of the CIty of Springfield and tbe Laws of the State of Oregon pertammg to the work deSCribed herem, and
that NO OCCUPANCY will be made of any structure WIthout permISsIOn of the Commumty ServIces DIVISIOn, BUlldmg Safety
I furtber certJfy that only contractors and employees who are 1Il comphance WIth ORS 701 005 will be used on thIS proJect
I further agree to ensure tbat all reqUIred mspectlOns are requested at tbe proper tJme, tbat eacb address IS readable from the
street, that the permIt card IS located at the front of the property, and tbe approved set of plans wilt remam on the SIte at all
times dUrIng constructIOn
Owner or Contractors SIgnature
Date
Paee 5 of 5