HomeMy WebLinkAboutOccupancy Correspondence 1994-3-15
,
~u-cr"
225 FIFTH STREET
SPRINGFIELD OR 97477
(503) 7263753
FAX (503) 7263689
CERTIFIED LETTER
Mm'ch 15, 1994
McKay Investments
2300 Oakmont Way
Eugene, OR 97401
Subject:
Occupancy Inspection at 1792 Centennial Blvd., Sprmgfield, Olegon.
p, oposed Use:
Church Meetings
To Whom It May Concern:
At your request, the Community Services D!Vl~ionIBUlldmg Safety conducted an IIIsprction
of the bUlldmg at the above address. The purpose of the inspection was to determme the
sllltablllty of the bmldmg fOl the proposed use as IIIdlcated.
Based on the plOposed occupancy, the eXlstmg condItIOns wInch are mentIOned below do
not meet the mimmum BlIlldmg Safety Code reqlllrements. Con echve l11eaSIll es must be
taken prior to occupancy to mstall, repmr, ,'eplace 0" modify the followlllg Items III 0' del
for the blllldmg to conform to applicable safety codes:
STRUCTI)RAL
1. I am pleased to 'eport we found no slgmflcant condItions wluch deviate from the
Buildmg Safety Code lequirements for the proposed use.
2. PrOVide one class 2A fire extmglllshe, mounted m an approved locatIOn tlwee to five
feet from the finished nom.
ELECTRTCAL
3. The electl ical service panel contams unused openmgs m its pi otechve face plate
which must be closed with clrcmt breakel s 01 blank fillers
4 All Clrclllt breakel s m the electncal panel sl1<l1l be p' operly labeled
McKay Investments
Occupancy Inspection
Page 2
5. Remove non-metallic cable and replace the circuit with a condUIt wiring method, as
explained in our previous conversation.
6. Strap exposed conduit within three feet of each box or coupling and at least each ten
foot thereafter, as explained m our previous conversation.
PLUMBING
7. All unused plumbing connections shall be properly plugged or capped.
A licensed electrical contractor is required for all new work and alterations to existing
electrical systems in structures which are for sale, lease or rent. However, the replacement
of parts for electrical devices which is necessary for maintenance of approved existing
electrical installations may be done by the owner of the property.
If you need any further informatIOn or have any questions regarding the above
requirements, please contact the appropriate inspector noted below between the hours of
8:00-9:00 a.m., 1:00-2:00 p.m., or 4:00-4:30 p.m. at 726-3759.
Sincerely,
j'om f1~
___.L ;J~>o
Jim Hays ()
Electrical Inspector
!l~~~<:1
Ral~iShaw
Plumbing/Mechanical Inspector
Tom Marx
BUlldmg Inspector
cc: Dave Puent, Community ServIces Manager
Hlllvlew Baptist Church
1444 Menlo Loop
Springfield, OR 97477