Loading...
HomeMy WebLinkAboutPermit Electrical 2016-10-05EQUIPMENT MATERIAL LIST: ITEM QTY DESCRIPTION REFERENCE 1'- 14 8 FT. 4 -LAMP STRIP FLOURESCENT WITH 32W T8 LAMPS LITHONIA TC232 2 5 320W METAL -HALIDE WALLPACK LITHONIA T.WR2 3 1 PHOTOCONTROL WITH CONTACTOR, INTERMATIC K4121 4 2 1OKW, 240V HEATER, KING ELECTRIC 5 12 RECEPTACLES, GFCI. DUPLEX, 20 -AMP, SURFACE MOUNTED. 6 4 RECEPTACLES, GFCI. DUPLEX, 20 -AMP, SURFACE MOUNTED. LEGEND d EXISTING HOUSE WITH ALL ELECTRIC AND GARAGE UTILITY 120W F032 T8 865 LAMPS 20 TRANSFORMER �B 320W METAL -HALIDE WALLPACK 120/240V, 1� 0 PHOTOCONTROL WITH CONTACTOR TOTAL <3> 10KW, 240V HEATER CAN NOT BE USED WITHOUT WRITTEN PERMISSION 20A, 120VAC DUPLEX RECEPTACLE ® 20A, 120VAC GARAGE DOOR RECEPTACLE 0 PRELIMIINARY NO. UTILITY POLE d EXISTING HOUSE WITH ALL ELECTRIC AND GARAGE UTILITY NEW SHOP HEAT 20 TRANSFORMER R NEW SHOP INSIDE LIGHTS 120/240V, 1� LOAD ANALYSIS DESCRIPTION KW EXISTING HOUSE WITH ALL ELECTRIC AND GARAGE 30 NEW SHOP HEAT 20 NEW SHOP OUTSIDE LIGHTS 1.6 NEW SHOP INSIDE LIGHTS 1.8 NEW SHOP RECEPTACLES 2.5 TOTAL 55.9 DISTRIBUTION POLE 3" PVC, SCH. 40 (2) 500MCM XHHW AL. (1) 350MCM XHHW AL. 320A METER MAIN W/ 2 FEEDER BREAKERS O 320E METER MAIN (2P)�q 000A (2P)( 200A 2" PVC, SCH. 40 2" GRC NIPPLE (2) 4/0 XHHW AL. (3) 3/0 THHN/CU. (1) 2/0 XHHW AL. (1) #6 THHN CU. GND (1) #4 XHHW AL. GND 200/2 200A PANEL ( 200/2 -E 200A PANEL A ONE r DIAGRAINI v REVISION I BY I DATE caLFs� DSGN: BAR IS ONE INCH ON ORIGINAL DRAWING DRN: 0 1" IF NOT ONE INCH ON THIS SHEET, MUST SCALES ACCORDINGLY CKD: REUSE OF DOCUMENTS THIS DOCUMENT IS THE PROPERTY OF OLSSON INDUSTRIAL ELECTRIC & ALL SUBSIDIARIES AND APC: CAN NOT BE USED WITHOUT WRITTEN PERMISSION dWP O I I I � I '® I I wp,� — — — -- — — — �� -i j WP I Ad i I � i IA I I i -- J I-- --- B I i DO 200A PANEL i $1 320A METER MAIN D -I LIGHTING PLAN Scale:3l3�'—I'-0" N DRAWING #: OLSSON LAURAIS PERM rT SHT. 1 of DATE: I PR03ECT: GARAGE SERVICE (E) SEPTIC Tank (E) 5t1ED 1 — PANEL FACING ( �—� App rOX.) HOUSE SERVICE 200A OUTSIDE BUILDING _ _ _ ._ _ _ ------ 320 n METER 200A PANEL FACING— ------------------------------------ --------------------------- n INSIDE BUILDING _ _ 36' 2� MAIN 200A PANEL i ± NOTE I — — INSIDE GARAGE 125A------------- _n— 2" GRC NIPPLE I I (� / /� I� /� / NOTE 2H ou (E) 3-3/0 Ttit1N/Cu5*— -#6 Tti11N/cD GND m (Unheated Space) 2" PVC SCH 40 TO TO TO 2" PVC spare GARAGE POLE t10USE 2" PVC spare 1 j j i (P) 320 Meter Main 2" PVC spare- -�c--------------, – 1 i I 3" PVC 2-500 MCM XMMW AL 2" PVC 1 1 1-350 MCM Xt1tiW AL 2-4/0 X11HW AL ------ 1-210 XHHW AL — 1 44 XHHW AL GND (P) (�efeed PWR o NR 200A Servlce. P X10' -O" \ � (P) 2" UG Conduit PSR % + (P) 3" UG Conduit 230. 4r—Q ! � I ! (P) Underground ! Power, Verl NOTE: 1 (E) = EXISTING (P) = PROPOSED ! i NOTES: 1. REMOVE OLD METER BASE. NEMA 3R PANEL MOUNTED TO hOUSE IN OLD METER BASE LOCATION. 2. REFEED HOUSE WITH NEW 125A BREAKER 12" GRC NIPPLE WITH 2-# 1 THHN Cu, 142 TI-11-iN Cu, I -#G THHN Cu GND, VERIFY CALES DSGN: CUSTOMER: TITLE: E''I BAR IS ONE INCH ON ORIGINAL DRAWING rg 0 r. DRN: IF MT ONE INCH ON THIS SHEET, AD}VS� SCALES ACCORDINGLY CKD: 0 PRELIMINARY RK/5J 10/3/16 REUSE OF DOCUMENTS THIS DOCUMENT IS THE PROPERTYOE OLSSON DRAWING #: OLSSON LAURAI5 PERMIT SHT. 1 Of REV N0. REVISION BY DATE INDUSTRIAL ELECTRIC & ALL SUBSIDIARIES AND APD: CAfI NOT BE USED WITHOUT WRITTEN PERMISSION DATE: PROJECT: 0