HomeMy WebLinkAboutPlan, Tentative APPLICANT 6/21/2016V
V
M
V)
CL
N
N
0
�i
0
N
O
N
CO
EXISTING WALMART STORE
FFE = 470.00± 9 - 7" 98-2
3 0 2659 OLYMPIC STREET
0i SPRINGFIELD, OR 97477
MAP & TAX LOT: 17-03-25-44-03600 cq a
WT
f
00
PROPOSED MODULAR BUILDING
FLOOR AREA = 35061
X
V � 3
4
V (1J
0
PROPOSED SEWER LATERAL, CONNECT
<=
TO EXISTING ON–SITE SEWER
6"SS
1� MODIFY EXISTING PARKING
LOT IMPROVEMENTS N
co RELOCATE LIGHT
6"SD POLE 468.27 RIM
462.27 12"INV
461.7218"&24"INV
0
C� 3
N� 18"SD
SDMH n
468.99 RIM00
vw
462.49 611INV ,
9
462.19 18"INV 3 C)
--,�—> cC 1pW cu..
MODI Y EXISTING +PING PR®POSE® �o
LOT IMPROVEMENTS MODULAR 0 �o
BUILDING
• ; PROPO D WATER � � r----
3,061± SF ERVIC TAP INTO
FFE 471.0± O
81.57' ,WATER MAIN
• V)I
I
468.40 AC PVMT EXISTING
467.03 AC PVMT SDCB
• a 466.58 TOG
462.78 INV
p
00
OC& ELEC
PROPOSED DRY UTILITY
SERVICES '
EXISTING PARKING TO
REMAIN
�3
i\ I\ 11 11%W I V
REMAIN
/ ✓v
EXISTING PARKING TO
REMAIN
/
a
s GRAPHIC SCALE
20 0 10 20
ko mi
(IN FEET)
1 inch = 20 feet
HEIGHT - 22± -1 `� �-�4M x4 LEGEND
3 AC ASPHALT
T1 j'UN FFE FINISH FLOOR ELEVATION
INV INVERT �±
-}13€i{?ird85 PVMT PAVEMENT PARKING DATA
t 3M' RIM MANHOLE RIM
00M SDCB STORM DRAIN CATCH BASIN PARKING REQUIRED:
SDMH STORM DRAIN MANHOLE PARKING RATIO = 1 STALL PER 250 SF
TOG TOP OF GRATE
�( t✓ �"�" � (PER CODE MINIMUM)
CLEANOUT EXISTING PARKING - WALMART
FIRE HYDRANT EXISTING BUILDING = 219,359± SF
SANITARY SEWER MANHOLE EXISTING STALLS = 1,003 STALLS
EXISTING PARKING RATIO = 4.57 STALLS PER 1,000 SF
STORM DRAIN MANHOLE PROPOSED PARKING - WALMART
1
PROPOSED MODULAR BUILDING = 3,061± SF
YARD LIGHT
CENTENNIAL STREET TOTAL BUILDING = 222,420± SF
STANDARD = 815 STALLS
—✓–> EXISTING DRAINAGE FLOW DIRECTION COMPACT = 132 STALLS
GRAPHIC SCALE BOLLARD
• ACCESSIBLE = 25 STALLS
TOTAL PARKING = 972 STALLS
80 0 40 80 — — — --- PROPERTY LINES
VIII®III�111®� PROPOSED PARKING RATIO = 4.37 STALLS PER 1,000 SF
- EXISTING ELEVATION CONTOURS
(IN FEET) REQUIRED PARKING (1:250 SF) = 890 STALLS
1 inch = 80 feet GAS GAS LINE
SS SANITARY SEWER LINE NOTES:
UNAUTHORIZED CHANGES AND USES: .The engineer preparing these pians will. not be responsible for, Engineers Note to Contractor: BENCHMARK: j) O s0 STORM DRAIN LINE
or liable for, unauthorized changes to or uses of these plans. All changes to the pians must be 1. EXISTING BUILDING SIZE TAKEN FROM BUILDING EXPANSION
In writing and must be approved by the preparer of these plans. The existence and location of any underground utilities, THE BASIS OF ELEVATIONS IS BASED UPON W WATER LINE PLANS PREPARED BY PACIFIC LAND DESIGN PLANNING,
pipes, and/or structures shown on these plans were THE CITY OF SPRINGFIELD BENCHMARK NO. ENGINEERING, & DEVELOPMENT SERVICES AND DATED JULY 8,
Construction contractor agrees that in accordance with generally accepted construction practices, obtained by a search of available records. To the a �Ei_EC�}--- PROPOSED ELECTRIC LINE
2005.
construction contractor will be required to assume sole and complete responsibility for job site best of our knowledge, there are no existing utilities 180, BEING A CHISELED SQUARE AT THE CALL TWO WORKING OC&'
conditions during the course of construction of this project, including safety of all persons and except as shown on these plans. The contractor shall NORTHWEST CORNER OF 28TH AND —'� 2. EXISTING PARKING COUNTS ARE BASED ON ORIGINAL
property, that this requirement shall be made to apply continuously and not limited to normal ascertain the true vertical and horizontal location and OLYMPIC, BEFORE DAYS BEFORE
PROPOSED FIBER OPTIC CABLE &TELEPHONE
ELEVATION BEING 468.25. ADD 0.32 YOU DIG YOU DIGSS CONSTRUCTION PLANS AND A REVIEW OF AVAILABLE AERIAL
working hours, and construction contractor further agrees to defend, indemnify and hold design .sizePROPOSED SANITARY SEWER
. a# those to be used of any underground utilities FEET ± TO CONVERT TO NAVD 29 (PER CITY PHOTOGRAPHS.
professional harmless from any and all liability, real or alleged, in connection with the performance and shall be responsible for any damage to any TOLL FREE 1-800-332-2344 E1 PROPOSED WATER LINE
of work on this project, excepting liability arising from sole negligence of design professional. public or private utilities, shown or not shown hereon. I
OF SPRINGFIELD SURVEY DEPARTMENT OREGON UTILITY NOTIFICATION CENTER (OUNC)
UJ o
LU
e lox
O
DQ W GQW
U IS
aQ>-Q�6r-zoo �a¢
NI'�t/,m Q�SU
Ousa- L4 L',az,ng-3
F=
0aCL W.
flow was a
V N
�o
ui
m
C;
m
•
K =
s
V
0
O{
•
-a
U U
IMP
W O
c�
a�
UJ o
LU
e lox
O
DQ W GQW
U IS
aQ>-Q�6r-zoo �a¢
NI'�t/,m Q�SU
Ousa- L4 L',az,ng-3
F=
0aCL W.
flow was a
;J41 4=J*
MA,
•
•
ISSUE BLOCK
CHECKED BY: SI
DRAWN BY STB
PROTO: 192 NON SC EXP
DOCUMENT DATE: 06/17/16
NOT FOR
CONSTRUCTION.
PRELIMINARY
SITE PLAN
SHEET:
ti m1