HomeMy WebLinkAboutSpecial Inspection Correspondence 1977-3-24
~ ..J
'",.
CITY OF SPRINGFIELD
SPRINGFIELD. OREGON 97477
DEPARTMENT OF
PUBLIC WORKS
March 24, 1977
346 MAIN STREET
747-4221
Mrs. Betty Rose
832 Centennial Blvd.
Springfield, OR 97477
Dear Mrs. Rose:
At your request the Building Department of the City of Springfield made an
inspection on March 23, 1977, of the structure located at 1300 North 28th
Str~et, Springfield, Oregon.
You stated that only the kitchen area of this building was to be used, therefore,
the inspection was limited to the area designated as the kitchen, said area
being approximately fifteen feet six inches by fourteen feet six inches with
an attached porch of approximately five feet by six feet.
This building is classified as an F-2 occupancy in Fire Zone III. The follow-
ing items are required to comply with the Uniform Building Code:
1. Water closet rooms in connection with food establishments where food is
prepared, stored, or served, shall have a nonabsorbent interior finish on
floors, walls, and ceiling and shall have hand washing facilities therein
or adjacent thereto.
2. All water closet rooms shall be provided with an exterior window at least
three square feet in area, or by mechanical ventilation capable of providing
a complete air change every 15 minutes, and the discharge shall be at least five
feet from any openable window.
3. An unobstructed space of at least 32 inches shall be provided in front of
the toilet.
4. The wall that seperates this portion of the building from the rest of the
building shall be a l-hour firewall with no openings. This will require
5/8" type-X sheetrock on both sides of this wall placed on studs spaced 16"
on center.
5. Steps shall be provided at the entrance with a rise not exceeding 7~ inches
and a run not less than 10 inches. All risers and steps shall be equal.
6. The broken hub on the weatherproof electrical panel must be replaced.
, .
, .
Mrs. Betty Rose
March 24, 1977
Page 2
7. Electrical service must be grounded to cold water pipe.
8. Loom wire in bathroom must be protected.
9. The switch on the deep fryer must have a cover.
10. All breakers under 30 amp must be in the lower section of the panel with a
main breaker ahead of them.
All necessary permits must be obtained before work begins and all work shall be
accomplished according to applicable codes and inspected before a Certificate
of Compliance will be issued.
Should you need further information please feel free to contact the Building
Department of the City of Springfield at 726-3753.
Sincerely,
~
Dan Smith
Building Inspector
DS:smm
-4'
, "\~"
~'"",, iT, 'ic'.....,.;,f.fv;.~ ~
CITY OF SPRINGFIELD
SPRINGFIELD. OREGON 97477
FIRE DEPARTMENT
4TH AND 'NORTH A STREET
746-6544
March 28, 1977
Mrs. Betty Rose
832 Centennial Boulevard
Springfield, OR 97477
RE: Request to Use the Old Airport Cafe
1300 North 28th Street
Springfield, OR 97477
The following items are required to be complied with prior to occupancy.
1. Compliance with all items listed by the Building Department.
2. Approved landing at entrance. See uniform building code for
minimum standard.
3. Do either of the following:
A. Remove existing fry grill or-
B. Install approved venting system over grill.
4. Display approval of compliance from State Health Department.
5. If natural gas is to be used,' all equipment shall be installed
in accordance with National Fuel Gas Code, ANSI 2223.1 and
approved.
6. Install approved 511 A.B.C. Type Fire Extinguisher.
7. The remaining portion of the building shall be kept secure
from entry and shall not be used for any purpose before
approval of use is first obtained from this department.
~~relY,. '
&~j);a~
A.M. Matsler, Lieutenant Inspector
SPRINGFIELD FIRE DEPARTMENT.
150 North 4th Street
Springfield, OR 97477
AM:ba