HomeMy WebLinkAboutMiscellaneous Correspondence 1983-10-21 -- -- - SPRINGFIELD lJl'l'Y OF SPRINGFIELD Department of Public Works October 21, 1983 / Ms. Jackie Grubb Lane County Housing Authority 125 East 8th Avenue Eugene, Oregon 97401 RE: Housing Report for 625 East Centennial Blvd., Springfield, Oregon Dear Ms. Grubb: The enclosed is a supplemental list to your existing report detailing deficiencies in corrective actions necessary. These items shall be included as part of the original report and corrective action shall be necessary for obtaining substantial compliance to the Springfield Building Safety Codes. STRUCTURAL AND FIRE AND LIFE SAFETY Walls/Ceilings/Floors Add Item #4: When the damaged wall coverings are removed , from the bedroom walls, the walls shall be insulated to R-ll. A vapor barrier shall be installed on the warm side. This should correct wet walls. Also, as a recommendation only, bird eye vents may be installed above bottom plate line in each wall cavity to assure a circulation of air". --'- Exterior Add Item #5: The foundation vents are required to have wire mesh with 1/4" openings. ELECTRICAL SAFETY 1. Add to Item #1: is inadequate to more than 6 main There is no room report. Replace the existing service panel. It serve any additional branch circuits. No disconnects are permitted for any service. for adding the circuits required on the 225 North 5th Street · Springfield. Oregon 97477 · 503/726-3753 .. -- Ms. Jackie Grubb 625 East Centennial Blvd. October 21, 1982 Page 2. 2. Add to Item #2: Install one or more small appliance circuits in the kitchen - extension cords are very hazardous. 3. Add to Item #6: Ground electric heaters in kitchen, bathroom, utility room and any other heaters in or near grounded areas. These have been installed on unground- ed wiring and are unsafe because they have no ground. Internal wiring can short out to metal case thereby causing a shock hazard to exist. 4. Add: Item 7. Install separate circuit for the washing machine. 5. Add:' Item 8. Install separate circuit for the clothes dryer '. MECHANICAL 1. The clothes dryer vent is to be exhausted to the exterior and be equipped with a damper. PLUMBING Add Item 2: A shut off valve is not required for the wall mount sink faucet, but a 3/4" full way gate valve shall be installed on discharge side of water meter. Please direct all inquiries to the Springfield Building Safety Division at 726-3753. Sincerely, iPu-y' gthvt;.:~~~/ Roy Bordeaux Plumbing Inspector I .DA-&11/h1~Z~ J'4"~'" 1/"/ James R. Matteson Electrical Inspector ch