HomeMy WebLinkAboutPermit Building 2000-1-17 CONDITION OF APPROVAL: , .. . .,,: " ~,.,)4:;~"> The "Soil SUr\;'~Y'Qf Lalle County" indicates Ihat soil ollthis site has a moderate Or high ....... I.,",' ...... shrin,klsvveH'poter~tial. The permit appl icant chooses to address this by havi ng <11 icensed design professio6al:evaluate the soils during excavation. Prior to placement of form work '- '. ",_'. ,.',:1'. '~1":,,v::(Wj.,'.~r " ' . the excay~,tion,'shQ:uldbe evaluated and a report prepared addressing the expansive soj].for . \. . . . the pror)osed foundation. Before the City will allow the foundation pour, a re.port from a licensed design professional rnust be on:-site for the BuHdinglnspector. If this information is notavaHable the inspection will be denied, and a reinspection fee nlay be charged. I.f a I.icenseddesigl~'professional proposes an option not listedbelow, the proposal mllst be slIbmittedforCityplan,review. After review, the approved docunients must be on-site aoel available kwthe Bljildinglnspector before the ioundation inspection will be approved. - ,," ..:~. - ,;_~l~i~~"" -. . . . , OPTION,,;1' Th'(;;' cQ'qtractormay ch()os~to excavate tq a depth that assures'stable moisture. In this G.dse the re~prt sha IliLndude: " ,,~:A;';f;;;::;~ii:':;~~J{;:, ' a Date'the'eVdl~ation wasnlade; C Icication evalWlted (i.e, address or tax lot and thearf~a of the site evaluated); Ca staternenl b~jthe licensedclesign professiona,l indicating the depth and \viclth of excavation is adequate to as~.ured stable moisture content for the proposed founddtion; , a thest(lmp dnd5ignatufe of the'!icensecl design profession{:~,_. !?' . ',". OPTION 2 ;;"The c!e'sign pr()f(:'s~ion<d I1klV choosp to spt>cif\' (,ornpal'wcI fil: Iii acicl;t'l...i :~) excavati~JD:.;-lrl;-thi~'cas~ th;~';;;(;,~t-(TiJTn~aucr(~:' ---~ . ' "':"':)1'1;:i.r;:', "\}~h;, C E?Atf.!he;,evalpatic)n ,\t\'dS rnad(~; . ''';i''','' ...' ..' - ! C locdti0n~evah:.iated(i :'e., address or tax' lot dnd the ~Hea of the sitee.valualedj; ,r', ",,".;;:"" < '. a a, stJt~ITl,erit:~\~;i!h~licellsecl desigFl professional indicating the depthdnd width of the j" .exca~a,ion an~1 the engineered fill is adequate 10 assure a stable llloisture,contelH for the I,Vf'()p()sed f(~l.W~~l,tiOIl; ''- C sPElci{!,~<.I~ioJ~~tforplac:emetlt! cOl1'lp':1Cti('ln, and testing of the en,gineered fill; C the;st~mp and\lsigl'lature of,the Hcensed design professiolla I.. l' i - .... )'''J",i"t,;"., . ' ~ Note: \A:,sep~~'lt~r,~P'ROr-tiroll1 <1 specialinspection,firm ()r licensed engirwer must ,.ddress the plilcem,ent'a,mUortesting Qf. th~~ engineered fill., - ~~..-. --... ,. ,.:~ ;', ';)' . ~l:o.< . - ' . OPTJON,3,;7)ThelicE~nsed desj<.c;n uroi'essionJI rnav c1etel'1ninl~ that soils \Vitl1'OI1Iv 10\\' ()!' no f. I '~'(' .~.','f' t. . ,"'.1 '";". '..: I ' shrink!s~vel,I:Hoter,lrt~),::,f~xists. In this case' the report shall inclucle: , ' " \:'~ ,:~/;;t;:,;',r~tJffiH{; l ' iii ' Ddte,'t.!leevdIH.'ltioF] Wd~ 111,:1<'\(>; . '. . .......,.. ., C locdli(i)n evaluated {i.e" ;tddr(:'~s or tax lot .:md Ih(~ ;11"(;11 of the site eV;JI,U,lled!;' ._ '. 'J~> t;~~:;.j." . " C a,stJi~;~nent bithe licens.ed design professionalindicdting only low or no shrink/svv(~1! !)(deniiJI exists.....,:' ",' ,:,:\::+", " '. a the stampancJ'signalure (If thl:' licE'nsed design !)rofesc,iof.J,:11. ,; :1 ~ ,: 1; i ,'\ .:.:: r::; " ~~'< ..." ln~";J Infonnation 11!!~,~,l1b Build On Engineering . Consu~ing . Testing 0'\'\ 121374. 7$ " '\ '6' "Co ~ ~ ~~ ~ ~ ~ ~~' ~ \ ~Jl~ OC' '01.1 , 6~8ZLl9t~'L January 17,2000 Mr. Ron Sather City of Springfield Dept. of Public Works 225 North 5th Street Springfield, Oregon 97477 Subject: Ambleside Meadows Subdivision 31 stStreet, Springfield, Oregon PSI Project No. 722-90227 Dear Mr. Sather: As requested by Glenn Ling of Ling and Associates, we have completed a general geotechnical evaluation of the subsurface soils for lots 81 to 172 of Ambleside Meadows Subdivision. The subject lots are anticipated to contain one or two story single-family homes. Home construction will typically consist of wood framed structures with crawl spaces within the living areas and slabs on grade within the garages. Existing lot grading ranges from nearly level to slopes on the order of 15 percent and steeper. Generally, the grades become steeper at the south end of the project. Our scope of work included performing a limited subsurface exploration, laboratory testing and an engineering analysis. It should be noted that PSI's services have previously been retained to provide full time inspection of any structural fill placement occurring within the subject lots. Subsurface Exploration At the time of our subsurface exploration, most of the site grading to prepare the lots for sale had been completed. The subsurface exploration consisted of , excavating 5 test pits within the house lots with a trackhoe and observing open trenches parallel and adjacent to streets. Locations of the test pits are indicated on the Test Pit Location Map at!ached. Specific soil units encountered in the test pits are briefly discussed below. ' Fill -" dark brown silty clay, moist to wet, organics, non-structural, observed'some small cracks (generally less than 3116" wide) when allowed to dry indicating moderate potential for shrink- swell. .... "'-- Silty clay - dark brown to light brown to mottled orange, moist, soft to very soft, organics, observed some small cracks (generally less than 3116" wide) when allowed to dry indicating moderate potential for shrink-swell. Clay - light brown to light grey, moist, firm to soft, observed large cracks (up to approximately 1" wide) when allowed to dry indicating high potential for shrink-swell. Clayey sand - mottled or~nge to grey, moist;hard. Professional Service Indus~ries. Inc, '6032 N, Cutter Circle. Suite 480, PO, Box 17126' Portland, OR 97217' Phone 503/289.1n8 . Fax,503l289.1918 PSI File No. 722-90227 January 17, 2000 2 The observed subsurface description is of a generalized nature to highlight major subsurface stratification features and material characteristics. The test pit logs included 'in this report should be reviewed for specific information at individual test pit locations. The stratifications shown on the test pit logs represent the conditions only at the actual test pit locations. Variations may occur and should be expected between test pit locations. The stratifications represent the approximate boundary between subsurface materials and the actual transition may be gradual. Laboratory Testing Selected samples of the subsurface soils were returned to our laboratory for further evaluation to aid in classification of the materials. The laboratory evaluation consisted of visual and textural examinations, moisture content determinations, gradation analysis and Arterberg Limits testing. Consolidation-swell tests were performed on the dark brown sandy lean clay (sometimes referred to as "granular clay" in our field inspection reports). The sandy lean clay soil was tested because it is predominantly the soil found within the upper 2 to 3 feet of the lots. Based on visual observation of the underlying sandy fat clay and fat clay with sand soils, we visually determined them to be highly expansive and did not perform consolidation-swell testing. The sandy lean clay soil was remolded at two different moisture contents--below optimum--and percent compaction prior to testing. The results of the consolidation-swell tests indicate that sandy lean clay is moderately expansive when near optimum moisture content, 26.5 percent (when compacted to 93 percent of a Standard Proctor, ASTM D698). At 26.5 percent moisture and 93 percent compaction, the sample required a confining pressure of 1,500 psfto offset its propensity to swell. A second test conducted at 18 percent moisture content and 90 percent compaction, resulted in a required confining pressure of 2.500 psf ' Conclusions and Recommendations The following issues will influence lot development. I. Non-structural sandy clay fill has been spread loosely inconsistently throughout the lots. Some portions of the fill contain a significant amount of organics, including topsoil and grass sod. This material is not appropriate for supporting building foundations or slabs on grade and should be removed in its entirety within the limits of the foundation and slab on grade. On January 10, 2000 Mike Dewey of PSI documented the following summary of estimated non-structural fill on the lots. It should be noted that the depths of fill may vafy significantly from what is reported below. Additionally, lots not mentioned below may also contain non-structural fill that was not visually apparent. A. Lots 81-90: 1 to 4 feet of non-structural fill. B. Lots 94-105: 1 to 2-1/2 feet of non-structural fill. e. Lots 111-116: 1 to 3 feet of non-structuralfill. D. Lots 122-124: up to 1 foot of non-structural fill; E. Lots 144-145: 6 to 8 feet of strip pings and sod stockpiled within the swale that borders the lots. Note that this is anticipated to be outside of the building pads but should be confirmed during pad construction. F. Lots 146-154: t.h to 1 foot of non-structural fill. PSI File No. 722-90227 January 17, 2000 3 G. Lot 155: approximately 1 foot of non-structural fill placed on unstripped original grade. Because it' is highly likely there is buried non-structural fill on some lots that PSI is not aware of, it is imperative that PSI explore the sub grade soils down to the native undisturbed soils within each lot prior to foundation construction. 2. Expansive soils were generally. encountered within the upper 7 feet of the test pits. The expansive soils, when allowed to dry and hydrate, will experience significant shrinking and heaving. The expansive soils, if allowed to repeatedly change moisture content during the wet and dry seasons, ;will negatively impact the perfonnance of the house foundations and slabs on grade. We do not recommend constructing foundations and slabs on grade without implementing preventative measures. In order to protect the expansive soils from repeated moisture content change, we recommend that footings bearing on expansive soils be overexcavated and replaced with at least 12 inches of crushed stone structural fill (i.e. % or 1-1/2 inch minus) compacted to at least 95 percent of ASTM 0698, , ' '\ Additionally, we recommend that fmish grade adjacent to the exterior portion of the footings and slabs be at least 2 feet higher than the expansive bearing soils. This is to provide a buffer from environmental ) changes that could cause the expansive soils to dry and hydrate. It will be imperative that the 2-foot buffer of landscape soil be compacted to a finn condition to reduce the infiltration of water at the surface. During foundation construction, water should not be' allowed to collect in foundation excavations, on floor slab areas, or on prepared, subgrades of the construction area either during or after construction. Undercut or excavated areas should be sloped toward one comer to facilitate removal of any collected rainwater, groundwater, or surface runoff. Additionally, the expansive clay soils should not be allowed to dry out during excavation. We suggest providing a granular surface cover 6 to 12 inches of%" minus crushed stone immediately after exposing the expansive soils, and no later than the same working day, Positive site drainage and foundation drains should be proviged to reduce infiltration of surface water around the perimeter of the building and beneath the floor slabs. The pennanent grades should be significantly sloped away from the building areas and surface drainage should be collected and discharged such that water is not pennitted to infiltrate the backfill and floor slab areas of the residence. All crawl spaces should be provided with a low-point crawl space drain connected to the stonn sewer or approved disposal system (outlet). All areas of the crawl space should be graded to drain to the low-point drain. All crawl space areas should be covered with a vis queen moisture barrier. The low-point drain should be lower than the elevation of the visqueen moisture barrier. If the expansive material is used as structural fill, it should be compacted at least 2 to 3 percent above' , optimum moisture content as detennined by the Standard Proctor method, ASTM 0698. The moisture content of the fill material should be unifonn. Care should be taken not to overcompact the material-90 to 95 percent compaction as detennined by ASTM D698 is recommended. . The above recommendations' are general in nature and should not 'be implemented without retaining PSI to observe individual lot subgrade conditions prior to foundation construction. We anticipate that a test pit will need to be excavated within the crawl space of the building pad to confinn the presence and depth PSI File No. 722-90227 January 17, 2000 4 of non-structural fill and expansive 'soils. At that time, PSI will determine if the recommendations contained in this report are appropriate for specific lots. If we can be of further assistance, please call Troy Hull in our Portland offic.e at (503) 289-1778 or Brian Currier in our Springfi~ld office at (541) 746-9649. . Respectfully Submitted, Professional Service Industries, Inc. EXPIRES: 6/30 0 I U:;1PJ for Troy Hull, P.E. Project Engineer Charles R. Lane, P .E. Senior Geotechnical Engineer TMH:tmh Cc: Glenn Ling, Ling and Associates Miles Breadner, Breadner Parker and Associates Ltd. Brian Currier, PSI-Springfield Attachments: Test Pit Location Map Test Pit Logs Laboratory Testing Results General Notes S:\shared\groups\ 704\geo eval\ 72290227 Professional Serv, ice I d n ustries , GROUND E ltABlfsrDE ~H~:llONS , OCT. 1/116 III AND rv . ~YERS 39. 40 .:.~ No,- ... ~c."l.,' . ~J j j, I "..-:/: ll. _ ...12 -- --. r1 /~ 10 /...~ ./ PROJECT NAME PROJECT NO, AMBLESIDE MEA ' LOTS 81 _ 172 DOWS SUBDIVISION 31 ST STREET, SPRINGFIELD, OREGON 722-90227 TEST PIT LOCA nON MAP DATE JANUARY, 2000 PSI A-300-6 ,\ ~J "',i Professional Service Industries; Inc. RECORD OF SUBSURFACE EXPLORATION Boring l)HP -t!J Project Name: ).r1&e')m;:~"S 5(J'B1)IV 1<; IOf'J Site: [iJ.-t' :,",5" '~.: Dr c.v~~;:s--(; S'rZ5" ON f'At.-CON 'DK'.:. DES~IP1lON .SURFACE _ 'PA'/:..1"- ~~ -S1L..,1 c.L..Ai Lr:,t.....:.':~), ~ ~ : I1QI~'-, CJ~ArJl(.S (aeA.5'S hJ1:> ~0'nS) . . = l-'"H" B~N FM 'Cl.A'(,(CIi 1 } .rll~.M 11..0 1'S , . . . MortLeP 0'j!..Jq.J.bE!- 10 ~..., ~~f?f "S~ ("S~) I I=l~ 1 /"r",~-r- f!.wu cr f'1-O'IJ \......... JQcS ~ M ItJ ~flJc::t- ~'T14I c:n)~ ] . t30H . . . PSI A.l CIO-ll D€PTH SAMPLE N . 7- .. 3 . t .. 51' 5 . u .. . .. .. . Date of Boring: )O/~J't7 I I Project No.: 7Z:L- '1022-7 011 Op Me REMAAAS .. . .. 11 .. . . .. & Professional Service Industries, Inc. , RECORD OF SUBSURFACE EXPLORATION Boring~HP-~ Project Name: At1BI.oo:.JDC" M~tr:.D\IJ'$ <C)~bNr:;,'oN Site: ~ "" 6?:S' f'J. or c.u~ ~ :"i~ -r3~N ~. DESCRIPTION .' .SURFACI: PAr...K ~N S l'-T"'f CJ,.A.'1 (a-t'U-), ~I ~ f'AI)/~j"1 o~1<-'S (6f!.A'S~ 1<N"i.) ~) . :- - L/~rrr 6'PE1 FA-r- CJ.A;1 (<::.J-f)) FI~ ,f'\or'S'r . Lt(;>MT B~'" Fk1~"'1 <..c:.I'I} f'l~ /'Iol'5'T" I I · t"\O~ QIU<N~ W e,t2-ej ~"I~1 'S~ (, S"G. ) / H~I "''''~,.. . [~c.:r ~ ~~ ,/'tlD /11).1~ tm.V<:nle.e J Jlo BOH II II . . PSI ~.loo-i1 ~ DEP11'I SAriPLE N .. z.. 3 .. 1 . 5.. ... .. .. ..l .. ,Date ~f Boring: 10 (s !7~ "\ Project No.:..:! Z:2-Qo22..i Qu Qp Me REMARKS II .. . .. II .. .. II D Professional Service Industries, Inc. RECORD OF SUBSURFACE EXPLORATION, Boring __ 'BHP(G) Project Name: !a181..2:!S1"PG- HGkt;o-.N'S .:5uaz, Nf~'cN Site: t,:;:) -- -eso' N. t>t= ~ €. ~.,... "1+05 nN ~~'" 'De., OEsCRlP1'tOH DEPTH SAMPLE I ')URPACE _ Pt\t.1'- ~~N~I"'T'f C-J-+.."1 (&......-1'11-; 'l~1 ~IF'T I - ""'Ol~"r" ~~'!I~ ,.1.tt4~] . .. -' . -z.. - /....1 "KT G:.~ FA.. ~"'(c:.H) FI/1...n MOI~ . , I .. 1.16H"- '6~N ~~1(dt),'FI~f MoW"'" i ~ · S--r _ M~ oAANa"E TO 612E( c.t-A'iEl ~ANl> (~(...." t'1~ MOI~r ) \ I 1- · . ~l-Ic:r FtJ;NoJ "'fE;ci\)~ (Lh'1I~AmI>~$) At-rr> t1'",~ ~r.T'tJ~:5J ' It-- 5.. BOH. - " . c.:,- . . . . . . l'SI ....,ClO-9 ,Date of Boring: (O~e.\ 9"'\ ,Project No.: -rZ2-<joz:z-:7 N Ou Qp Me REMARKS . . . .. ., . . . II: Professional Service Industries, Inc. RECORD OF SUBSURFACE EXPLORATION . Boring '6 H p-tD) Project Name: AHB~~rb&:: fJ\~'J')(N...I"", $J3nl~I5..l2.b' I ' sne(D)~ ...v,-1O ''5". ct=" c..uq ~ 51", 3...,.0(:1 o1>J Fkl rr-J/'J '2:IJe.. DESCRIPTION . DePTH SAMPI.E , I III . L-I ,,1-f"T'" ()f2ei fkr ~""''i C CJ1 ') I f I f!..M I f1 0 \"5"1 2. . . . . . - &S 3 . 1- .. s- - S.S (p . Date 01 Boring: l().fe./~~ I ' Project No.: ,'2-2 -Cirr"-'-' N Qu SUAI=ACC 1"\.... ,...et:> o~e jl) 10.1 ~H"I t3~~ S"11..'rI ~'1 (11L.- c:..l.-.) ;:50?-r- /1ol~1 ) ) , ~l-Ic.... /'1.lf.,JElik!..- :!S"nwqv~J (pJrDw.:'SU!t FII.L.) Qp Me; -+ 3c".1 -..3l.." RE::MARKS . III .. . . .. Professional Service Industries, Inc. RECORD OF SUBSURFACE EXPLORATION, Borin~ 6Hf-(t) Project Name: k1gL~S'l"D.e:; ~'::'A-bo'f'JS :'5l):B"DI\II1'5'ION Date 01 Soring: ~10/8/ 9<1 Site: (i) --.;L. 75"1 i5. I")F 6J~ ~-r: 5' ~+ 01'-J Fkl...co,.j nliL Project No: cfSCRIPnOH , OEPTH SAMPLE N au Qp Me II '5URFACE. ' H.~ o~tJ~e= ro WbM'r ~~/oJ ,,:>(...'11 ~""1(f'\.\..-(:"'l...)' ~fi MO\5"- , I (j!a.lc:r MI}..le:~ ~c:w~ 1 [p~aNlU= f1u-l .. II D~ e~oNtJ '511,..01 ~ ((:.l..-~) J ~s:;~ ~o'fT', I4C\~"- '2. . L LI c.+1. 'I B~.tNJ I-J f7{r~""1 CUi)) F I ~ , . MO\~ 3 . -: . /"\oi'il..l?D c:> f2.kN (:I ,;: 1"0 ~" "11:l /..,~ 5'~"+J~ u..k1~' "'f)t'<ND ("5~) ) t\~, HO\"'5T t .. . [f-E-l-1er' ~ l~i~'.Ji.e'S /O-ID K.IJ.1~ '51W(;!V~ J L;:)L-l . .. ""'N~ 1~'S J s- . .. . (p .. Bor{ .. . .. . - \ .. . PSI,.,.I00-9 REMARKS ~ ~ . .. .. . 11\ .. II' Sheet 1 of 1 ~ Liquid Plastic Plasticity Maximum %<#200 Class- Water Dry Satur- Void Borehole Depth Limit Limit Index Size Sieve ification Content Density ation Ratio (mm) (%) (pcf) (%) BHP-A 3.0 55 24 31 9.5 64 CH 31.0 BHP-C 2.5 '60 25 35 4.75 74 CH 32.0 Lot 147 I 3.5 49 25 24 4.75 51 CL 37.0 ~ o C> Ii tt: o (,,) Ci5 ll. ...., ll. C> ....: ~ ~ "- >- tt: ~ ::;: ~ '" S ~;, I~ Engineering Consulting Testing 6032 N. Cutter Circle 1>uite #470, PortTand. Oregon 97217 Phone (503) 289-1778 Fax (503) 289-1932 !!; Summary of Laboratory Results Client: City of Springfield Project Name: Ambleside Meadows Subdivision Project Location: 31st Street, Springfield, Oregon Report Number: 722-90227 . @ @)/ ~ // .00/ ~/' , /. // /' /' @ @ 40 60 80 100 LIQUID LIMIT LL PL PI Fines Classification 55 24 31 64 SANDY FAT CLAY CH 60 25 35 74 FAT CLAY with SAND CH 49 25 24 51 SANDY LEAN CLAY CL I, 1-- o Cl ~. o l..l Cii <>. -, <>. Cl ...: N 8 N N .... Vl I- ~ ::::; A TTERBERG LIMITS RESULTS Client: City of Springfield Project Name: Ambleside Meadows Subdivision Project Location: 31st Street, Springfield, Oregon Report Number: 722-90227 '~., ,114:::!.!I ' Engineering Consulting Testing 6032 N. Cutter Circle ~uite #470,'Porfrand, Oregon 97217 Phone (503) 289-1778 Fax (503) 289-1932 Cl 0:: W '" 0:: W ~ Vl ::>r ~ J 70 ' (J,S, SIEVE OPENING IN INCHES U,S, SIEVE NUMBERS 6 4 3 2 1,5 1 3/4 1/2!~ 3 ... 6, 8101416, 20 30 40 5060 100140200 I ' "\ I I' -'\ -'f!::~1 . I :' I . I I I .. "'" I '" ." I I '- f \ Ir \~ I\. '\ I '\ i "" ... :~ , :\\ ":l . \\' HYDROMETER 100' 95 90 8e 80 75 C~ l- I Q 60 w ~ >- :~ co 0:: ~ 50 u.. I- 45 z w ~ 40- w a. I , I 3~ 30 2~ 20 I' 15 10 ~ o 100 10 0.1 0,01 0,001 COBBLES : GRAVEL coarse 'I fine GRAIN SIZE IN MILLIMETERS SAND medium I fine SILT OR CLAY LL PL PI Cc Cu 55 24 31 60 25 35 49 25 24 coarse I Specimen Identification' . BHP-A IZI BHP-C ~ Lot147 Classification SANDY FAT CLAY CH FAT CLAY with SAND CH SANDY LEAN CLAY CL Specimen Identification b. BHP-A CJ gi IXI BHP-C o () ~ Lot 147 1ii '" .., '" CJ ~ N , N '" 0100' 9.5 4.75 4.75 060 -) 030 010 %Gravel %Sand %Silt I %Clay 1.8 34.2 64.0 0.0 25.8 74.2 0.0 48.6 51.4 0.134 W N [en z ,~ CJ tIl :l . ~., ,,~ Engineering Consulting Testing 6032 N. Cutter Circle 1>uite #470. Portrand, Oregon 97217 Phone (503) 289-1778 Fax (503) 289-1932 GRAIN SIZE DISTRIBUTION Client: City of Springfield Project Name: Ambleside Meadows Subdivision Project Location: 31 st Street, Springfield, Oregon Report Number: 722-90227 F.~I:~.:.&Ional Service Industrles 0.1 0.2 0.:1 0.4 O.S 1 2 345 10 2025 -3 0-. -. -2. - ~~ ----------------- . '\ ~ -1 \ (~ \ 0,-:, \--------------- - ll'.e '-" 1 c:: o 'N co co G) ~ 2 8 u ',--------------- o \ __ ________L____.:...__ ______ ~l 3--- ___I 4 5 _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ---0.. __ 0.1 ' 0.2 0.3 0.4 0.5 1 2 3 4 5 10' 20 25 Pressure. (XSF) SAMPLF . ~OL Approximate Ewe" Pressure 90% R.C. @ w~18% o 2,500 psf S4,.J p,/ L..E 1\...1 L L"" '-I . --_._-'~---- EXPLANATION. SAMPLE LOADED AT t" J.J:.1-l) MOISTURE SAMPLE SATURAJ,jU.J SAMPLE TESTED UND.ErR REBOUND LOADING PAOJECT NAME Ambleside Meadows CONSOLIDATION TEST REPORT PROJECT NO. 722-90227 DATE ~ovember 1999 PSIA.-10G03 ProfesslonalServlce Industries ~- 0.1 -1 ~---- 0 ------ ----- 1 ---- .--... 2 ~ '-' c: ----- 0 .,-j 3 co ----- a] qJ \.4 ----- ~ 6 0 u 4 ---- 5 ------ 6 ----- 7 0.1 SAMPLE , 0..2 0.3 0.4 0.5 2 1 3 4 5 10 2025 0- _ , -- ~ -,...i-l.~-----~-------------- - - - - - - - - -....:; - - ~ - - - - - _...: - - - --- - - - - -- , ....... > - - - - --:. - - - - - - - - -'- - - _..:. - - - - - - - - - - -, , _..!.L__________________________ 1,,",,",,-__ ___ _ ___ _ __________ - - - - - - - - - - - -..... - - - - - - - - ---- - - - - - -- -- , 'I ----------- ------"---- ------- --- -------------- ------------- I -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 0.2 0.3 0.4 0.5 1 2 3 4 5 10 20 25 ,', Pressure (XSF) SYMBOL Approximate Swe11 Pressure o 93% R.C. @ w=26.5~ 1.5QO n~f I EXPLANATION. SAMPLE LOADED A. T FIELD MOISTURE -----'------ SAMPLE SA Tr.JRA. TED SAMPLE rESTED UNDER REBOUND LOADING S4NO~/ LEA,.} i..L.A,'1 PROJECT NAME Ambleside Meadows PSI A-l~ CONSOLIDATION TEST REPORT PROJECT NO. . 722-90227 DATE November 1999 ** TOTAL PAGE.03 ** Professional Service Industries GENERAL NOteS SAMPLE IDENTIFICATION The Unified Soil Classification System is used to identify soil unless otherwise noted. , SOIL PROPERTY SYMBOLS N: Standard Penetration Value: Blows per foot of 140 pound hammer falling 30 inches on a standard split-spoon penetrometer. Ou: Unconfined compressive strength (ts~. Op: Penetrometer value, unconfined cOlDpressive strength (tst). Mc: Water content (%). lL: Uquid limit (%).' PI: Plasticity index (%). ~d: Natural dry density (pcf) , \7: Apparent groundwater level at time, noted after completion. DRilLING AND SAMPLING SYMBOLS SS: Split-Spoon - 1 3/8. I.D., 2" O.D. SB: Spilt-Barrel- 2 3/8" 1.0., 3" 0.0. ST: Shelby Tube - 3" 0.0., except where noted. BS: Bulk Sample. AU: Auger Sample. DB: Diamond Bit. eB: Carbide Bit. WS: Washed Sample. RELATIVE DENSITY AND CONSISTENCY CLASSIFICATION TERM (NON-COHESIVE SOilS) STANDARD PENETRATION RESISTANCE Very Loose Loose Medium Dense. Dense Very Dense 4 or less ,4 to 10 1 0 to 30 30 to 50 Over 50 TERM (COHESIVE SOilS) OU - (TSF) Very Soft Soft , Medium Stiff Stiff Very Stiff Hard o - 0.25 0.25 - 0.50 0.50 - 1.00 1.00 - 2.00 2.00 - 4.00 4.00 + PARTICLE SIZE ~r; Boulders Cobbles Gravel 8 in + 8 in-3 in 3 in-5 mm Coarse Sand 5mm-Q.6mm Medium Sand 0.6mm-Q2mm Fine Sand 0.2mm-Q.074mm Silt 0.074 mm-Q.005mm Clay 0.005mm