HomeMy WebLinkAboutPermit Building 2003-4-17 (2) MORTIER ENGINEERING, I!C. STRUCTURAL BUILDING DESIGN . FIRE PROTECTION CODE CONSULTANT · PLAN CHECKING CONSTRUCTION INSPECTION 1245 PEARL STREET EUGENE. OREGON 97401 PHONE (541) 484-9080 . FAX (541) 484-6859 TOLL FREE IN OREGON 1-877-661-9959 April 17, 2003 Scott Jordan 28235 Clear Lake Rd, Eugene, OR 97402 RE: Lot 133 Ambleside Subdivision - Proof Roll - W.O.#15305-ARC As you requested, a site visit was performed on April 16, 2003 in order to determine if the compacted fill adequately meets the requfrements for the placement of foundation, The fill consists of 3" minus crushed rock, The maximum depth of fill is approximately 36 inches. No extraordinary deflection was observed due to the testing of -the fill with a fully loaded dump truck, which weighed 48,280 pounds, The compacted surface of the crushed rock is adequate to support a conventional wood frame residence with a standard foundation per the 2000 State of Oregon One and Two Family Dwelling Specialty Code as adopted per the local jurisdiction, The compaction of the gravel surface is'greater than 95% of a standard proctor, per ASTM 0698-91. Thank you for this opportunity to be of service, The enclosed Building Analysis Report and Statement of Conditions and Limitations is a part of this report, If you have questions regarding this report, please contact me at 484-9080, Sincerely. Bradley R. Myers, P.E, , j MORTIER ENGINEERING, EC. STRUCTURAL BUILDING DESIGN. FIREI:'ROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION 1245 PEARL STREET EUGENE, OREGON 97401 PHONE (541) 484-9080. FAX (541) 484-6859 TOLL FREE IN OREGON 1-877-661-9959 CLIENT: Scott Jordan BUILDING ANALYSIS REPORT Statement of Conditions and Limitations LOCATION OF PROPERTY : Lot 133 & 137 Ambleside Subdivison WO# l5305-ARC h Type"of Inspection arid items inspected is limited to: a, b, c, d, e, ,f. g; - h, 'f. Structural Conditions Weatherproofing (Exterior surfaces) Stonn Drainage (Building, Site) Site Conditions (Soils, Geological) Plumbing (Fixtures, Piping) Heating (Furnace, Heat Pump, Air Conditioning, Fireplace, Stoves, Chimneys) ", Electrical (Service, Wiring, Outlets) Other p~\:' 12-oL.L The inspectio'n is for the purpose of alerting the client to major deficiencics in the condition of the property described above and according to the conditions contained in the report and this state'ment The inspection and report are perf011lled and prepared for the sole, confidential and exclusive use and possession of the CLIENT, No obligation or responsibility to other parties is assumed, This inspection is of the readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection, Latent and concealed defects and deficiencies are excluded from the inspection; equipment, construction and systems will not be dismantled, Maintenance and other items may be discussed, but they are not a part of our inspection, The report is not a compliance inspection or certification for past or present government codes or regulations of any kind, ' The inspection and report do not address and are not intended to address the possible presence of or danger from any potentially harmful substances and environmental hazards including but not limited to radon gas, lead paint, asbestos, urea formaldehyde and toxic or flammable chemicals, Any references made to these substance in our report is made for the sole purposes of alerting our client to the possibility of their existence, We are making no positive determinations as to their actual presence, as we do not do laboratory testing, If CLIENT wishes any further information or recomm'endations in regard to tile presence of these substances, we recommend contacting a specialized environinental contractor. , The report describes the property condition and status on the date of inspection, :rhe purpose is to alert clients to present defects, Sub-surface soil conditions, inaccessible areas and features, appliances, security alanns, intercom systems, solar heating systems or panels, sprinkler systems, spas, pools, water softeners, central vacuum systems, and the presence or absence of rodents, iermites or other insects are specifically excluded from the scope of this report, While every reasonable effort was made to determine the property conditions, no guarantees' are expressed or implied, No responsibility is assumed for any items olltside the scope of this inspection, nor can we be held responsible for work' performed by others, Liability for damage arising out of errors or omissions shall bc limited to the cost of the scope of inspection, No representations are made conce11ling the architectural or engineering conditions, Mortier Engineering, its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects or deficiencies, either current or.arising in the future, or for any property damages, ,cOllsequential.damage or bodily injury of any nature, The inspection and report are not intended or to be used as a guarantee or warranty, expressed or irilplied, regarding the adequacy, perfOnllanCe or condition of any inspected structure, item or system:. For MORTIER ENGINEERING, Pc. g~rA,,~,-- Signature .r Engineer April 17, 2003 Title Date