March 13, 2003
Scott Jordan ,
28235 Clear Lake Rd.
Eugene, OR 97402
RE: 3342 Ambleside Dr. - Proof RolI-,W.O.#15158-ARC
As you requested, a site visit was performed on March 11, 2003 in order to determine if the
compacted fill. adequately meets the requirements for the placement of foundation. The fill
consists of 3" minus crushed rock. The maximum depth of fill is a'pproximately 36 inches. No
extraordinary deflection was observed due to the testing of the fill with a fully loaded dump truck,
which weighed 48,280 pounds. The compacted surface of the 9rushed rock is adequate to
support a conventional wood frame residence with a standard foundation per the 2000 State of
Oregon One and Two Family Dwelling Specialty Code as adopted per the local jurisdiction. The
compaction ofthegravel surface is greater than 95% of a standard proctor, per ASTM 0698-91.
Thank you for this opportunity to be of service. the enclosed Building Analysis Report and
Statement of Conditions and Limitations is a part of this report. If you have questions regarding
this report, please contact me at 484-9080.
'1
, Sincerely,
.'
Bradley R. Myers, P.E.
. '..' .., .~;". '" .:: '.
1245 PEARL STREET
EUGENE, OREGON 97401 ,
PHONE (541) 484-9080. FAX (541) 484-6859
TOLL FREE IN OREGON 1-877-661-9959
STRUCTURAL
BUILDING DESIGN. FIRE PROTECTION
CODE CONSULTANT .'PLAN CHECKING
CONSTRUCTION INSPECTION
MORTIER
ENGINEERING, EC.
BUILDING ANALYSIS REPORT
Statement of Conditions and Limitations
CLIENT: Scott Jordan
LOCATION OF PROPERTY : 3342 Ambleside Dr.
WO# ISIS8-ARC
I, Type of Inspection and items inspected is limited, to:
a, Structural Conditions
b. Weatherproofing (Exterior surfaces)
c. Storm Drainage (Building, Site)'
d: Site Conditions (Soils, Geological)
e. _ Plumbing (Fixtures, Piping)
f. Heating (Furnace, Heat Pump, Air Conditioning, Fireplace, Stoves, Chimneys)
g. Electrical (Service, Wiring, Outlets)
h, V Other r'(t.<.4 ( f/-G- LL
The inspection is for the purpose of alerting the client to major deficiencies in the condition of the property described above and according to the
conditions contained in the report and this statement. The inspection and report are perfonned and prepared for the sole, confidential and
exclusive use and possession of the CLIENT. No obligation or responsibility to other parties is assumed,
This inspectioil is of the readily accessible areas,ofthe building and is liniited to visual observations of apparent conditions exisiing at the time of
the inspection, Latent and concealed defects and deficiencies are excluded from the inspection; equipment, construction and systems will not be
dismantled,
Maintenance and other items may be discussed, but they are not a part of our inspection, The report is not a compliance inspection or certification
for past or present government codes or regulations of any kind,
The inspection and report do not address and are not intended to address the possible presence of or danger from any potentially hal111ful
substances and environmental hazards including but not limited to radon gas, lead paint, asbestos, urea fOl111aldehyde and toxic or flammable
chemicais, Any references made to these substance in our report is made for the sole purposes of alerting our client to the possibility of their
existence, We are making no positive detel111inations as to their actual presence, as we do not do laboratory testing, If CLIENT wishes any
further infonmition or recommendations in regard to the presence of these substances, we recommend contacting a specia-Iized environmental
contractor.
The report describes the property condition and status on the date of inspection_ The purpose is to alert clients to present defects, Sub-surface
soil conditions, inaccessible areas and features, appli'ances, security alanns, intercom systems, solar heating systems ,or panels, sprinkler systems,
spas, pools, water softeners; central vacuum systems, and the presence or absence of rodents, tel111ites or other insects are specifically excluded
from the scope of this report. While every reasonable effort was, made to detel111ine the property conditions, no guarantees are expressed or
implied, No responsibility is assumed for any items outside the scope of this inspection, nor can we be held responsible for work performed by
others, Liability' for damage arising out of errors or omissions shall be limited to the cost of the scope of inspection, No representations are made
concerning the architectural or engineering conditions,
Mortier Engineering, its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects
or deficiencies, either current or arising in the future, or for any property damages, consequential damage or bodily injury of any nature, The
inspection and report are not intended or to be used as a guarantee or warranty, expressed or implied, regarding the adequacy, perfomlance or
condition of any inspected structure, item or system,
For MORTIER ENGINEERING, p,c.
~,JA ~~
Sigilature ' .r
Engineer
March 13,2003
Title'
Date