Loading...
HomeMy WebLinkAboutPermit Fire Deferral Submitted 1986-2-13 . - SPRINGFlELD CITY OF SPRINGFIELD Fire Prevention Bureau Building Division February 13, 1986 Mr. Les Swaggart 2!5 S. 'A' Street Springfield, Oregon 97477 Subject: Fire Department referral at 25/5 S. 'A' Street, Springfield, Oregon Dear Mr. Swaggart: At the request of the Springfield Fire and Life Safety Department, the Building Safety Division recently conducted an inspection at the above address. The inspection revealed the following conditions which must be corrected in order for the building to comply with applicable City Codes. The existing paint spray room used in the fabrication of vehicle hitches does not meet the minimum building code requirements for the following. reasons: 1. Inadequate area separation between the paint spray room and adjoining uses. An area separation wall is required to reduce the hazard area to under 1500 s.f., or the entire building must be sprinkled. 2. Inadequate fire protection of exterior walls facing adjacent building and property line. The existing structure housing the paint spray room was apparently enclosed without benefit of permits and inspections, as is evident by the overspanned wall sheathing. 3. Improper roof covering. The use of plastic roof covering materials is restricted by the Building Code. A fire retardant roof assembly is required. 4. Inadequate exits. Two exits are required for paint spray. rooms over 200 s.f. in area. 5. Inappropriate exhaust system with insufficient clearances from struct- ures and property line. Unless an approved water wash system is used, the exhaust termination must be located at least 30 feet from property lines, and a minimum of 10 feet above adjacent grade and 6 feet from exterior walls or roofs. Additional clearances are required from openings. and adjacent buildings. 6. Lack of an inter-tie connection between the spray system and mechani- cal exhaust system. 7. Unprotected electrical devices and raceways in paint spray area. All such devices in a paint spray environment must be of an explosion proof type. 8. A fire sprinkler system is required for the paint spray room (and the rest of the building if the area separation wall noted in item 1 above is not provided). Due to the comparatively more extensive requirements involved in the construction of an approved paint spray room, we recommend that an approved paint spray 225 North 5th Street . Springfield, Oregon 97477 · 503/726-3753.503/726-3737 . . booth which has been constructed as specified in the Uniform Fire Code be installed for your painting requirements. If such a booth is installed, the following requirements would apply: 1. An area separation will not be required between the spray booth and the adjoining uses. 2. The exterior wall structures must be rebuilt to provide proper support for fire resistive wall coverings. The south and west walls must include a parapet 30 inches above the roof, and must be of 1 hr. fire resistive construction due to their proximity to the property line and the building to the west. 3. A fire retardant roof system must be installed. 4. Provide two exits from the paint spray area located at least 12 feet apart. If the exit is located in a fire resistive wall, the door assembly must be rated for 3/4 hour fire resistive construction. 5. To avoid the exhaust system termination requirements, an approved water wash exhaust system for the paint spray booth could be provided. 6. Provide an inter-tie connection between the paint spray and exhaust systems, so that the spray will not operate unless the exhaust system is running. 7. Explosion proof electrical eq uipment and wiring systems are req uired. within the paint spray booth, or, if an open type booth is used, within a 20 foot radius of the spray area. In addition, explosion proof equipment and wiring systems must be used outside the booth within a 3 foot radius of all unsealed openings. 8. Install fire sprinklers only in the paint spray booth. 9. Provide fire extinguishers as required by the City Fire Marshal. Permits will be required for the above noted corrections. Please submit plans for the required modifications to this office in order to obtain the necessary permits. Please note that a fabrication facility which has existed for some time on property zoned Community Commercial, is considered a non-conforming use by the City Zoning Ordinance. For the existing fabricating use to remain on this property, the existing structure must be proper ly constructed and maintained. If the structur:e is vacated for 30 consecutive days, any subsequent use of the structure must conform to all provisions of applicable City Ordinances. If you have any questions, please call the Building Safety Division at 726-3753. Sincerely, 1!:tJ;!~ Structural Inspector cc. Mike Hudman, City Fire Marshal