Loading...
HomeMy WebLinkAboutPermit Mechanical 2014-6-25 SPRINGFIELD 225 Fifth St CITY OF SPRINGFIELD Springfield,OR 97477 - t ``i Phone: 541-726-3753 OREGON Building / Commercial Permit Inspection Phone: 541-726-3769 Fax: 541-726-3676 PERMIT NO: 811-SPR2014-01367 www.springfield-ar.gov permitcenter@springfield-or.gov PROJECT STATUS: Issued ISSUED: 06/25/2014 EXPIRES: 12/21/2014 STATUS DATE: 06/25/2014 APPLIED: 06/25/2014 SITE ADDRESS: 3654 KATHRYN AVE,Springfield,OR 97478 SCOPE: Mechanical Only ASSESOR'S PARCEL NO: 1702304306401 TYPE OF STRUCTURE: Commercial PROJECT DESCRIPTION: Gas piping and appliance upgrades OWNER: CARVER FAMILY LLC Phone Number: ADDRESS: 1993 MISTY MEADOW DR FOLSOM CA 95630 CONTRACTOR INFORMATION Contractor Type Contractor Name Lic Type Lic No Lic Exp Phone Mechanical Contractor JCOO INC CCB 169209 05/06/2016 541-746-7065 L INSPECTIONS REQUIRED Inspections 2255 Gas Pressure Test 2300 Rough Mechanical Rough Mechanical: Prior to Cover 2310 Rough Gas Rough Gas: After line is installed and required testing and capped if not attached to an appliance. 2995 Final Gas Final Gas: When all gas work is complete. 2999 Final Mechanical Final Mechanical: When all mechanical work is complete. By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State or Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street,that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. nn Owner or Contractor Signature Date // NOTICE: ATTENTION: Oregon law requires you to THIS PERMIT SHALL EXPIRE IF THE WORK folowarulle addopt Those rules are s t fort AUTHORIZED UNDER THIS PERMIT IS NOT in OAR 952-001-0010 through OAR 952-001- COMMENCED OR IS ABANDONED FOR 0090. You may obtain copies of the rules by ANY 180 DAY PERIOD. calling the center. (Note: the telephone number for the Oregon Utility Notification Springfield Building Permit 6/25/2014 2:10:39PM Center is 1-800-332-2344). Page 1 of 1 • SPRINGFIELD CITY OF SPRINGFIELD 225 Fifth 51 • il :-act TRANSACTION RECEIPT 5pringtield,OR 97477 OREGON 541-726-3753 811-SPR2014-01367 www.springtield-or.gov 3654 KATHRYN AVE perrnitcenter©springtield-or.gov RECEIPT NO: 2014001373 RECORD NO:811-SPR2014-01367 DATE:06/25/2014 DESCRIPTION ._. -__ __ _ . . -- _ .ACCOUNT...CODE/TRANS CODE - AMOUNT DUE _ Continuing Education Fee 224-00000-425606 2.50 Mechanical Permit fee(based on value of work) 224-00000-425604 1006 324.00 State of Oregon Surcharge(12%of applicable fees) 821-00000-215004 1099 38.88 Technology fee(5%of permit total) 100-00000-425605 2099 16.20 TOTAL DUE: 381.58 ,_ PAYMENT TYPE, „_,PAYOR_ucASHIER_CCARPENTER _ COMMENTS AMOUNT PAID dit CreCard . _-------. _ JCOO INC — _.___ __ . 381.58 615211 TOTAL PAID: 381.58 • • • • • Mechanical Permit Application t DEPARTMENT USE ONLY 4 y 4, 2 .3!t ,- d C 11 YL,., . SPRINGFIEW i t°' �. Permit no.: 5/y- (367 7 ��;CITYOF S�RINGFIELDOREG01�i . � ,a 225 Fifth Street♦ Springfield,OR 97477 • PH(541)726-3753 • FAX(54I)726-3689 SIP Date: O/ZS// `/ This permit is issued under OAR 918-440-0050. Permits expire if work is not started within 180 days of issuance or if work is suspended for 180 days. ,i„. -1) , ;,CATEGORY OF, CONSTRUCTION + -5 .-.cc `-, f}1, :_i.(•r k, : jF,EE'SCHEDULE „f,] w ;thr ❑Residential ❑Government 0 Commercial Residential Cost Total } . _ n,_e Qty "rea cost ,- ..,, JOB?.SITE INFORMATION ;AND'LOCATION,;t ci ;gi. First Appliance $82.00 $ 3�OS� Furnace/burner including ducts and vents Job site address: o. '.r>i n 5•� Up to lOOk BTU hr. $19.00 $ City: ac�7r:-,S4ei I State: p2 ZIP: 9 241 7) Over 100k BTU/hr. $22.00 $ Reference: Taxlot.: Heaters/stoves/vents ';�,r { 'DESCRIPTIONdO F N O_ R K, a zr p g.;; Unit heater $19.00 $ �-. / Wood/pellet/gas stove/flue $43.00 $ J 1,54-I I 9A ! &,It-- 2--,2 Mi( - rid/,, O{. Repair/alter/add to heating appliance/ refrigeration unit or cooling system/ $82.00 $ tFt ar-1 t(5 t- /L/e,n,),i qyiS h C absorption system trt4.P) " � PROPERTY*NER .c,'' Q 17 Evaporated cooler $15.00 $ OI ' /��/, Vent fan with one duct/appliance $10.00 $ C Name: 11 C Hood with exhaust and duct $15.00 $ Address: (?6 3p,c cig(a Floor furnace including vent $82.00 $ City: F 156w,. State:(4 ZIP: 9S636 • Gas piping Phone:54-o5- y/11 Fax: - - One to four outlets $8.00 $ Additional outlets(each) $5.00 $ E-mail: Air-handling units, including ducts This installation is being made on property owned by me or a Up to 10,000 CFM $12.00 $ member of my immediate family, and is exempt from licensing Over 10,000 CFM $22.00 $ requirements under ORS 701.010. Compressor/absorption system/heat pump Signature: Up to 3 hp/100k BTU $19.00 $ 4 „ V•,CONTRACTOR nINSTALLATION ' , rtizi?,2;a Up to 15 hp/500k BTU $33.00 $ / Up to 30 hp/1,000 BTU $49.00 $ Business name: .eta �Yu"(h Up to 50 hp/1,750 BTU $64.00 $ Address: 7 9 M ki In Ai, titan Over 50 hp/1,750 BTU $107.00 $ City: /llel State: Oh ZIP: 6171770 Incinerators �1/1A5 Domestic incinerator $22.50 $ Phoned 7JJi 7 oc 5 Fax: tommii6i8 , sir.;6: ' : ,, :‘; ',::: ,.rf?. ",`c-"' ; E-mail: g„a.., e ,7,,(n,JC,L_,Or~ Enter total valuation of mechanical system / �O�r and installation costs$ 7 5-000 CCB license no.: t Enter fee based on valuation of mechanical system,etc. $ Print name: yn a., T/te/ F` t tu x ; s r ,i Costs' Total b --� mMlscellaneous fees Zr Items > e8 cus'ti Signature: L..- /'- Reinspection $82.00 $ Specially requested inspections (per $82.00 $ Regulated equipment(unclassed) _ $15.00 $ Each additional inspection:(I) $82.00 $ +r? :=ti:' `ai*APPLICANT4USE.,$, ' a;t„ .;° (A)Enter subtotal of above fees(or enter set minimum fee of $82.00) $ / (B)Investigative fee(equal to[A]) $ // (C)Enter 12%surcharge(.12 x[A+B]) $ e/� (D)Seismic fee, 1%(.01 x[A]) $ (E)Technology Fee(5%of[A]) $ G (F)Continuing Education Fee$2.50 $2.50 TOTAL fees and surcharges(A through F): $ )a-7 Si 440-2545-1(5/212014/COM) . • I ,. r'.X ki --Y O _j N . -i TO _ m D m r'l r—1 a L 1 N L d u m b Ir o O 3 C ICD CO V M T m _s M co m 0 � Z O x Q O z 4 D • O o-, I O o0) po rI = 93 m D �°� p ON o • _ 1 I 01 I o l o 1 o ri G r 3 tack O o G X ----e- ("71 .‘: —a • 3 moo c *• Z O - o n 0.00 0 T T m m 0-- z m m o A 7 p O c S m �_Hz 0 o z O� T 9 X m A A 0 o 0 a o cr.fl-< 3 en-1 j ' i. -e a _i 3 4 Q m m -o (� mpm 0\ o W i C N C K .< cQ -+ io I r- I'3 ` m '' m ° m m — 1 CO O J o { j • --1 't k, 66 , Nf` o o c o L_J 1 (D m o a r— OD N � O C f j Si trt S - O o o N j \ -< . a G > a C o • O m a m o A o O 0 zt 01 in p- � -, ' 1 I3PP ! k c o �b R O ? U et i 6. C g 5 S 0 [ F-,_ F-1 0 `l Fax: Sep 9 2005 06:59am P001/004 7)4(1 " 11564A 93D/NE 6-460.8 April,2007 T .0 Ce SUBMITTAL DATA D power vented gas-fired unit heaters Certified for Residential model HD and Commercial Use MOUNTINGHOLESTYP MOUNTING 3/8x1'LONG G I A BRAIXEr ADIUSTABIF POWERVFNIFJI Lomas { VENT%PE CONNECTION D117WG1 1 r � Cp1NECRON GAS C l CONNECTION E ��fi/O��1111; IIC,► III • - ' • I C DaDVING H___..1 ACaSS 1 PANEL REARVIEW Performance Dimensions (inches) Models HD30 ND45 HD60 HD75 I HD100 140125 Models 14030 1 HD45 111)60 HD75 HD10011 25 BWAir Input 30,000 45,000 60,000 75,000 100,000 125,000 A 26.8 26.8 28.8 26.8 35.5 BhVW Output 24,000 36,000 48,000 6 .000 80000 100,000 B 12.2 12.2 18.0 18.0 20.5 Entering Airflow(CFM) 505 720 990 1,160 1,490 1;980 C 16.5 16.5 16.5 16.5 22.0 Outlet Velocity 523 749 653 789 565 747 D 14.9 14.9 14.9 14.9 22.5 Air Temp.Rise('F) 44 46 45 48 50 47 E 10.1 10.1 15.9 15.9 18.4 Mounting Height(Max ft.) 10 10 12 . 14 12, 16 F 7.5 7.5 10.7 10.7 14.0 Heat Throw 90 25 27 36 38 42 ' 56 G 18.5 16.5 18.5 18.5 24.0 Horsepower 1115 1/15 1/12 1/12 1/12 1/8 H 7.6 7.6 7.8 7.8 8.4 Motor RPM 1,550 1,550 1825 1,625 1,050 1,550 Gas Connection 1/2 1/2 12 12 1/2 Data Type S.P. S.P. P.S.C. P.S.C. SP.. I P.S.C. I 34.5 34.5 34.5 34.5 43.0 Amps 2.4 2.4 1.2 1.2 2.7 2.2 J 22 22 25 25 31.0 Unit Total Amps 3.7 3.7 2.5 2.5 • 4.7, 4.2 Fan Diameter 10 10 14 14 18.0 Vent Connector Size(in.) 3 3 3 3 .4; 4 Approx.Shipping Weight(lbs.) 55 60 B0 85 125 Mounting Clearances 1"-angle,mounting brackets are slotted to accommodate joists Clearance To Recommended On 16"or 24"centerlines. �1Y{ Unit Side Combustible Materials Service Clearance 1 I I I Top and Side 18' 8 HD30-75 Access Slde 18' 18' 0 o a o 0 0 o Non-Across Site I' 1' 000 � NN Rear 18' 18" 0 = co• Vent Connector 4' 4' °p 0 0 0 0 0 H0100/125 � o •I o I o g QI I. g ' g 2 ° gggg2 ,' m s: of ._- � N N N N N � 4 Cl Control Options Control Description Control Service 'Thermostat lype of Model Code No. Voltage Voltage De Size SingleSYaie.Dived Spark Ignition,100%Shut-Ott with Continuous Reby 11 115V 24V natural 30-125 -MINN a single-stage combination gas control with igitm control. Gas isle with a direct spark igniter on canon heat 21 115V 24V propane 30-125 Two-Stage,Direct Spark Ignitton,100%Shut-Cm with Continuous Retry 12 115V 24V natural 75125 -Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100%and 50%of full rated input Gas is it with a direct spark 22 115V 24V propane 75-125 igniter on call for heat. Fax: Sep 9 2005 07:00am P002/004 tilt DATA �4r�e power vented blower gas-fired unit heaters LW and ComorResilUse model HDB and Commercial Use sax ITONG lEO TYP- G I `nrO pSeIE A BRACKETS POWER VENTER VENT PIPE CONNECTION F 14 -. u / I s GAS GONNELTON - i till PANE li • . _ OPENING 8 I I = •• __ _> C J I D OPENING H ACCESS VIEW REAR VIEW Performance Dimensions (Inches) Models HDB60 I HDB75. HDB100 HDB125 Btu/Hr Input 60,000 75,000 100000 125,000 HDB 60 HDB 76 HDB100/125 A 26.8 26.8 35.5 Btudir Output 48,000 60,000 80,000 100,000 Air Flow CFM Range 635-1100 795-1390)060-1850 1240-2050 B 18.0 18.0 5 20.5 Static Pressure(max) 0.7 0.7 0.8 0.8 C 16.5 5 16. 22.0 Air Temp.Rise(°F) 40-70 40-70 40-70 45-75 D .14.9 14.9 22.5 Motor Speeds 3 3 3 3 E 15.9 15.9 18.4 F 10.7 10.7 14.0 Horsepower 1/4 1/3 1/2 1,2 G 18.5 18.5 24.0 Motor RPM Max Max Max Max H 7.8 7.8 8.4 Data 1,1 00 1,100 1.100 1.103 Gas Connection 1/2 1/2 1/2 Typo P.S.C. P5.0. P.S.C. P.S.C. I 35.5 35.5 44.5 Amps 5.4 7.1 9.5 9.5 32.5 32.5 41.5 Unit Total Amps 6.4 8.1 11.5 11.5 Blower - 9-7 9-7 10- 10 Vent Connector Size(in.) 3 3 4 4 Approx.Shipping Weight(Its.) 92 97 151 Mounting 1"-angle,mounting brackets are slotted to accommodate joists Clearances or, 16"or 24"centerlines. JJ CltaranceTo Recommended 1� I I I I i i Unit Side Combustible Materteb Service Clearance 800 000 HD3a7s 0 n Top and Sonora 1- 1• ,- •- NN(n cc n m (N N Access Side 1' 18' I•o 4 o o 0 o 4 co 0 0 0 o 01 Non-Access Side 1' 1' 1 I I I I I 1 IAD100/125 I I I I I I I I Rear la' 18' co °n N 2 N 12 n o n o o Vent Connector 8 .- is VI r at ,- 4, r' g.ii cc cc N m (n Pi •Control Options Control Description Control Service Themmstd Type of Model Cade No. Voltage Voltage Ciao Size Single-Stage,Direct Spark lgniion,1 m%Shut-00 with Continuous Retry 11 115V 24V natural 30-125 •Utilizes a single-Maga combination gas conird with ignition comet. . Gas is In with a direct spark igniter on call for heat 21 115V 24V propane 30-125 Two-Stage,Direct Spark ignition 100%ShuI-OR with Continuous Retry 12 115V 24V natural 75.125 -Utilizes a two-stage combinaton gas control with built-in ignition control. Firing rate is 100%and 50%of lull rated input Gas is lit with a direct spark 22 115V 24V propane 75-125 igniter an call tor heat.2 2 6-460.8 Fax: Sep 9 2005 07:OOam P003/004 SUBMITTAL DATA ,T Q separated combustion gas-fired unit heaters and Co mercial Use HDS and Commercial Vse MOWING HOIFS TYP G ADJUSTABLE A MOWING 3/5 X1'LONG I WINDS PM/ERBIUM RACKETS 51G111 GLASS V�PIPE COW4KTxw 1- at5 CONNECTON UP Idly _// ;` I ATMs ��I OPENING f�Uirt0��1 VI IWO Al II • •. r ` G • o OPTICNG X III-- 1 mE1fMTSAL rNECION x ACCESS VIEW PEAR NEW Performance Dimensions (inches) Models HDS30 HDS45 HDS60 IHDS75 1-1138100 HDS125 Models HDS30 HDS45 HDS60 HDS75 HDS100/125 BIuMr Input 30,000 45,000 60,000 175,000 100,000 125,000 A 26.8 26.8 26.8 26.8 35.5 BWMr Output 24000 36,000 48,000 60,000 80,000 100,000 B 12.2 122 18.0 18.0 20.5 Entering Airflow(CFM) 505 720 990- 1,160 1,490 1,980 C 16.5 16.5 16.5 16.5 22.0 Outlet Velocity 523 749 853 769 565 747 D 14.9 14.9 14.9 14.9 22.5 All Temp Rise('F) 44 46 45 48 50 47 E 10.1 10.1 15,9 15.9 18.4 Mounting Height(Max ft.) 10 10 12 I 14 12 16 F 7.25 7.25 10.75 10.76 14.0 Heat Throw(R) 25 27 36 I 38 42 56 G 18.5 18.5 18.5 18.5 24.0 _ Horsepower 1/15 1/15 1/12 1/12 1/12 1/8 H 7.6 7.6 7.835 7.835 8.4 Motor RPM 1,550 1,550 1,625 1 1,625 1,050 1,550 Gas Connection 1/2 1/2 1/2 1/2 1/2 Dais Typo S.P. S.P. P.S.C. 1 P.S.C. S.P. P.S.C. I 34.5 34.5 34.5 34.5 43.0 Amps 2.4 2.4 12 1 1.2 2.7 2.2 J 22 22 25 25 31.0 Unit Total Mips 3.7 3.7 2.5 I 2.5 4.7 4.2 K 274 2.74 3.15 3.15 3.87 Vent Connector Size(in.) 3 3 4 I 4 ! 4 4 L 3.19 3.19 5.55 5.55 10.73 Fan Diameter 10 10 14 14 18.0 Mounting Approx.Shipping Weight(Ibs.) 55 60 80 86 125 1"-angle,mounting brackets are slotted to accommodate joists Clearances on 16'or 24'centerlines. is' r o aI E' Unit Side Clearance To Recommended 1 r Combustible Materials Service Clearance o �l o �l HD30'75 O o Top and Bottom 1' 1' n N I- Of t.1 92 N N NN Access Side 1' 18' Non-Access Side V 1' '° o q wl Rear - 16' 18" i t I I I I l 11 o " o 0100/125 1 I I I I I I o o v0 S 2 S 2 n N 2 S' u°f°o Vent Connector 4' 4" n n fn ti m ri N ni N 'RI N n n ,n Control Options Control Description Control Service Type Model Code No. Voltage Voltage Cma Size Single-Stage,Direct Speak Ignition,100%Shut-Off with Continuous Retry 11 115V 24V natural 30-125 -Mess a single-stage combination gas control wan ignition comfit. Gas is Ii with a diced spark igniter on cell for heat. 21 115V 24V propane 30-125 Two-Stage,Direct Spark Ignhlon,100%Shut-Off with Continuous Retry 12. 115V 24V natural 75-125 -Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100%and 5C%of full rated input.Gas is lit with a direct spade I 22 1159 24V propane 75-125 igniter on call for heat.e • 6-460.8 3 Fax: Sep 9 2005 07:OOam P004/004 t T SUBMITTAL DATA =:w:-. separated combustion blower gas-fired �M m a Certified for Residential unit heaters - model HDC and Commercial Use WONTING MOUNTING H ESTYP G AOJJSTABLE 9VENTER A muCxEPS 33211LONG SDHr�� I LCWER$ VENT mPE CONNECTION GAS CGNNCC ICN • I 6 10, scusi GHONNEfsrnlP.'• - • , PANEL OPENING 8 CF I C K� DECTHIQ J CONN N H D OPENING H REAR VIEW ACCESS VIEW Performance Dimensions (inches) Models HDC60 HDC75 HDC100 HDC123 Models HOC 60 HDC 75 HDC100/125 BW/Hr Input 80,000 75,000 100,000 125000 A 26.8 26.8 35.5 Btu/Hr Output 48,000 60,000 80,000 100,000 B 18.0 18.0 20.5 Air Flow CFM Range 635-1100 795-1390 1060-1850 1240-2050 C 18.5 16.5 22.0 Static Pressure(max) 0.7 0.7 0.8 0.8 0 14.9 14.9 22.5 Air Temp.Rise('F) 40-70 I 40-70 40-70 45-75 E 15.9 15.9 18.4 Motor Speeds 3 3 3 3 F 10.8 10.8 14.0 Horsepower 1/4 1/3 1/2 112 G 18.5 18.5 24.0 Motor RPM Mar Max Max Max H 7.8 7.8 8.4 . 1.100 1.100 MOD 1.100 . Data Gas Connection 1/2 1/2 1/2 Type PS.C. P.S.0 P.S.D. P.S.C. I 355 35.5 44.5 Amps 5.4 7.1 9.5 9.5 J 32.5 32.5 41.5 Unit Total Amps 6.4 8.1 11.5 11.5 K 3.15 3.15 3.87 Vent Connector Size(In.) 4 4 4 4 L 5.55 5.55 10.73 Rower 9-7 9-7 10-10 Mounting Apprar.Shipping Weight(lbs.) 92 97 125 1"-angle, mounting brackets are slotted to accommodate joists Clearances on 16-or 112,4"centerlines. i j Q ° �r I T Unit Side Clearance To Recommended Combustible Matedels Service Clearance So 0 0 0 0 H030-75 o dry Top and Bottom 1° V '' "' N- 0f r m N (N NN Access Side 1" 18" ° Non-Access Side 1" 1- i 4 °I o l H0100/125 • o a �1 1 1 1 ji i Rear 18° 18° 82, 285388 $ 88885888 VentConnector m N n' m 41 N ( N ` N N 1°I 'A n N Control Options Control Description Control Service Thermostat Type of Model Code No. Voltage Voltage Gas Size Single-Stage,Direct Spark Ignition,100%Shut-O f with Continuous Retry 11 115V 24V natural 30-125 -Utilizes a smgle•stalge ambinatbn gas control v/th ignition metro! Gas is Itt with a direct spark igniter on call for heat. 21 115V 24V propane ' 30-125 Two-Stage,Direct Spark Ignition,100%Shut-Off with Continuous Retry 12 115V 24V natural 75-125 -Utilizes a two-stage combinalbn gas control with built-in ignition control. Firing rates 100%and 50%of lull rated input.Gas is lit with a direct spark 22 115V 24V propane 75.125 igniter on call lot heat. Commercial Products Group • Modine Manufacturing Company • 1500 DeKoven Avenue • Racine,Wisconsin 53403-2552 Tel:262.636.1200 • Fax:800.204.6011 • www.modine.com 02007 Moans Manufacturing Company Litho in USA rfesteritho Sfaidard ADH1 C085-SPEC-1 A H E A T I N G & A I R C O N D I T I O N I N G TAG: SPECIFICATION Downflow/Horizontal 5/8• Direct or Non-Direct 21• ,g�,. ,g5e. 28" Vent Gas Furnace 3'OPENING Z-`'z, s ADH1 C085A9481 A 5/8" `/2„ AIR INTAKE �/' • 2"DIAMETER \� ` FLUE CONNECT 7/8"DIA.HOLES R1/B. ELECTRICAL -4 7/e'DIA.K.O. CONNECTION ELECTRICAL CONNECTION ? /B` R`''lie. (ALTERNATE) 1 19-1/2' 3141 1 : '` . 1-1/2'DIA. 3," ,n `. ,' 2110 y' 91• K.O.GAS '' CONNECTION (ALTERNATE) �t '�- CONDENSATE DRAIN,1-1/8"K.O. ",7-1/a' • RS'/2 le 1 20-1/4" 3/4 " I /i. a \ 13-3/4"re-- 40" 19' 10". I - 'Ica Ilk- e.,L. 7-3/8' „,,,„N '3'B• O 00 O'1g'60 9q/4e#76-4,6,N TF/N kO FURNACE AIRFLOW CFM)VS.EXTERNAL STATIC PRESSURE(in.w.c.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 4 HIGH- Black 1835 1772 1709 1637 1566 1485 1405 1313 1222 'DH1C085A9481A 2_ MED.-HIGH-Blue 1726 1674 1622 1557 1492 1416 1340 1252 1164 MED.-LOW-Yellow 1581 1539 1498 1440 1383 1321 1258 1172 1085 1 _ LOW- Red 1401 1374 1346 1308 1269 1209 1148 1075 1001 First letter may be "A”or"T" CFM VS.TEMPERATURE RISE Cubic Feet Per Minute(CFM) MODEL - 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 *DH1C085A9481A 70 64 59 54 50 47 44 41 39 37 '=First letter may be"A"or"T" ©2011 American Standard Heating&Air Conditioning • General Data a TYPE Downflow/Horizontal VENT —Size(in.) 2.5 Round RATINGS W HEAT EXCHANGER Input BTUH 80,000 Type-Fired Alum.Steel Capacity BTUH(ICS) O 76,000 -Unfired AFUE 95.0 Gauge(Fired) 20 Temp.rise(Min.-Max.)°F. 30-60 ORIFICES—Main BLOWER DRIVE DIRECT Nat.Gas.Qty.—Drill Size 5-48 Diameter-Width(In.) 11 x 10 L.P.Gas Qty.—Drill Size 5-56 No.Used 1 GAS VALVE Redundant-Single Stage Speeds(No.) 4 PILOT SAFETY DEVICE CFM vs.in.w.g. See Fan Performance Type Hot Surface Ignition Motor HP 1/2 BURNERS—Type Multipart Inshot R.P.M. 1075 Number 5 Volts/Ph/Hz 115/1/60 POWER CONN.—V/Ph/Hz () 115/1/60 COMBUSTION FAN-Type Centrifugal Ampacity(In Amps) 12.5 Drive-No.Speeds Direct-1 Max.Overcurrent Protection(amps) 20 Motor HP-RPM 1/20-3450 PIPE CONN.SIZE(IN.) 1/2 Volts/Ph/Hz 115/1/60 DIMENSIONS H x W x D F.L.Amps 0.71 Crated(In.) 41-3/4 x 23 x 30-1/2 FILTER—Furnished? No Uncrated(In.) 40 x 21 x 28-1/2 Type Recommended High Velocity WEIGHT Hi Vel.(No:Size-Thk.) 2-16 x 20-1 in. Shipping(Lbs.)/Net(Lbs) 171/160 O Central Furnace heating designs are certified to ANSI Z21.47/CSA 2.3. O= Ratings shown are for elevations up to 2000 feet.For elevations above 2000 feet;Ratings should be reduced at the rate of 4%for each 1000 feet above sea level. O Based on U.S.Government Standard Tests. O The above wiring specifications are in accordance with National Electrical Code;however,installations must comply with local codes. Mechanical Specifications NATURAL GAS MODELS — Central BURNERS — Multi-port, in-shot burners STYLING — Heavy gauge steel and heating furnace designs are certified by will give years of quiet and efficient service. "wraparound" cabinet construction is the American Gas Association for both All models can be converted to L.P. gas used in the cabinet with baked-on enamel natural and L.P.gas.Limit setting and rating without changing burners. finish for strength and beauty.The heat ex- data were established and approved under INTEGRATED SYSTEM CONTROL— changer section of the cabinet is completely standard rating conditions using American Exclusively designed operational program quiet and efficient o This results in lined with foil-faced fiberglass insulation. ulation. National Standards Institute standards. provides total control of furnace limit sen- due to the excellent acoustical and insulat- SAFE OPERATION—ThelntegratedSys- sors, blowers, gas valve, flame control ing qualities of fiberglass. tem Control has solid state devices,which and includes self diagnostics for ease of continuously monitorfor presence of flame, service. FEATURES AND GENERAL OPERATION when the system is in the heating mode of AIR DELIVERY—The multispeed,direct- — These High Efficiency Gas Furnaces operation. Dual solenoid combination gas employe Hot Surface Ignition system,which valve and regulator provide extra safety. drive blower motor, with sufficient airflow eliminates the waste of a constantly burning range for most heating and cooling require- pilot. The integrated system control lights QUICK HEATING—Durable,cycle tested, ments, will switch from heating to cooling the main burners upon a demand for heat heavy gauge aluminized steel heat ex- speeds on demand from room thermostat. from the room thermostat. Complete front changer quickly transfers heat to provide The blower door safety switch will prevent service access. warm conditioned air to the structure. Low or terminate furnace operation when the energy power vent blower, to increase blower door is removed. (Fan relay and a. Low energy power venter. efficiency and provide a positive discharge 35VA control transformer is standard). b. Vent proving differential switch. of gas fumes to the outside,allows common venting with hot water heater. oil ER Tea. Since American Standard Heating 8 Air Conditioning has a policy of continuous product and product data improvement, it reserves the right to change specifications and design C without notice. C J. [/aTEOU Technical Literature-Printed in U.S.A. American Standard Literature Order Number ADHIC085-SPEC-1A Heating&Air Conditioning File Number ADH1C085-SPEC-IA 6200 Troup Highway Tyler,TX 75711 Supersedes AUH1C085-5HEL-1 Date 12/11 www.americanstandardair.com CAPACITY K.1(BTU/ TURBULATOR GAS FLUE SHIPPING TABLE I: Ton L"rum IIOIIR)0 to 1.371,6110 mm PRESSURE &AIR WEIGHT Kg MODEL IENG'FII (4.510 ft.)ABOVE REQUIRED NOT & VENTS (LBS.) CONFIGURA- SEA LEVEL LENGTH REQUIRED ELECTRICAL TIONS IQ-200-70 21,234mm 3048 mm 147 Kg • (69'8") (10') (324 Lbs) - - - 210,000 Kj - LINE IQ-2013-60 18,288mm (200,000 Btu/hr) 3048 mm MINIMUM 128 Kg (60'0") (10') 12.45 mbar NG (282 Lbs) 15,342mm 3048 mm (5"W.C. NG) 109 Kg IQ 200-50 (50'4") (10') (239 Lbs) 27.39 mbar LP IQ-175-70 21,234mm 3048 mm (I I"W.C. LP) 147 Kg (69'8") (10') (324 Lbs) IQ-175-60 18,288mm' 184,712 Ki 3048 mm 128 Kg 1600") (175.000 Btu/hr) (10') (282 Lbs) IQ-175-50 15,342mm 3048 mm 109 Kg (50'4") (10') L/NE 1016 (239 Lbs) I S 288mm X MAXIMUM mm 128 Kg IQ-155-60 34.86 mbar (60'0") NG or LP 4" (282 Lbs) IQ-155-50 15.342mm 162,750 Kj X (14"W.C.) 109 Kg (50'4") (155,000 Btu/hr) (239 Lbs) IQ-155-40 12,395mm 3048 mm 90 Kg (40'8") (10') (197 Lbs) IQ-130-50 15.342mm X 109 Kg (50'4") MANIFOLD (239 Lbs) IQ-130-40 12,395mm 136.500 Kj 3048 mm 8.71 mbar NG 90 Kg (40'8") (130,000 Btu/hr) (10') (3'/z"W.C.NO) (197 Lbs) IQ-130-30 9,450mm 4267 mm 24.9 mbar 1-P 70 Kg (31'0") (14') (10"W.C.LP) (154 Lbs) 1Q-110-50 15,342mm X 109 Kg (50'4") (239 Lbs) • IQ-I IU-JU 12,395mm 115,500 Kj 3048 mm 90 Kg (40'8") (110,000 MAO ((0') 12.7 mm(%") (197 Lbs) IQ-111430 9,450mm 4267 mm GAS INLET- 70 Kg (31'0") (14') (154 Lbs) IQ-I00-20 6,500mm 115,500 Kj 3048 mm 50 Kg • (21'4") (110,000 Btu/hr) (10'S/S) (III Lbs) IQ-80-40 12,395mm 3048 mm 90 Kg (40'8") (10') ELECTRICAL (197 Lbs) — 9,450min 84,000 KI 4267 mm 120V,6013'7, 70 Kg IQ-80-30 (31'0") (80,000 Btu/hr) (14') 145 VA (154 Lbs) IQ-80-211 6,500mm 4267 mm 50 Kg (21'4") (14') (III Lbs) 9,450mm 4267 mm 70 Kg IQ-611-30 (31'0") (14') THERMOSTAT (154 Lbs) 63.000 Kj Factory ready for IQ-60-20 6,500mm (60.000 Btu/I Ir) 4267 mm 24V or 120V 50 Kg (21'4") (14') thermostat (III Lbs) 6,500mm 4267 mm control 50 Kg IQ 45-20 (21'4") 47.250Kj (14') (III Lbs) - (45,00013tuIhr) IQ-15-10 3.556mm 1524 mm 31 Kg (II'8) (5') (68 Lbs) AP-SSJSUX-04C 3 IQ 5D RI;JC RD'.SEP 2006 BA • a % • • . . • N 0 I 0 rn m VI 0 0 N aW 3 O a N N 3 0 a 3 3 J W_ NJ 0 N • N G 3 o _. n 3 q 1 3 k w 0 s :, 3 C m Co 0 3 a 4 N 3 � y N a m m O N O 3 3 0 3 < 3 3 T1 3 w U) o 3 m Cl, o m { 1v M N r� O 3000 3 3 w m 3 33 N • 3�T 3a Nv U a I O 3 —. p W 1 O W bi 01 a w 3 3 . 3 a W N m F, u� 3 p 3 I 3 3 • 0 m 3 3 N W AP-SSJS-BX-04C 4 IQ SD 111.4C RD.SEP 1006 BA 9 9 9 9 19 9 9 9 9 9 9 COMPONENT QUANTITIES 45-10 45-20 60.20 100-20 60-30 80-40 110-50 i 175-50 155.60 175-60 175-70 PER HEATER MODEL 80-20 80-30 110-40 130.50 200-50 200-60 200-70 110-30 130-40 155-50 130-30 155-40 - SWAGED TUBE(S): - 3048 mm(101 ALUMATHERM w/FLANGE 0 0 0 0 0 0 0 1 0 1 1 3048 mm(10') ALUMINIZED w/FLANGE 1 1 1 1 1 1 1 0 1 0 0 3048 mm(101 ALUMINIZED STEEL 0 0 0 0 0 0 0 1 0 1 1 3048 mm(101 EMISSIVE COATED STEEL 0 1 1 1 2 3 4 3 5 4 5 TUBE FOCUS SHIELD REFLECTOR 2947 mm(9'8") 1 2 2 2 3 4 5 5 6 6 7 ALUMINIZED COUPLER 0 1 1 0 2 3 4 3 5 4 5 ACCUSEAL TUBE CLAMP 0 0 0 1 0 0 0 1 0 1 1 END PLATE HANGER 2 2 2 2 2 2 2 2 2 2 2 WEBBED HANGER 0 1 1 1 2 3 4 4 5 5 6 REFLECTOR STABILIZER 3 6 6 6 9 12 15 15 18 18 21 TURBULATOR(S): 1524 mm(5')STAINLESS STEEL 1 0 0 0 0 0 0 0 0 0 0 3048 mm(101 ALUMINIZED STEEL 0 0 0 0 0 1 0 1 0 1 1 3048 mm(10')STAINLESS STEEL 0 0 0 1 0 0 0 0 0 0 0 4267 mm(141 ALUMINIZED STEEL 0 1 1 0 1 0 0 0 0 0 0 - HEATER QUANTITY ON PROJECT - OPTIONAL ACCESSORIES QUANTITY ON THIS PROJECT 90 DEGREE SWAGED ELBOW KIT JS-0508-JZ CUT-AWAY BURNER VIEW 1 elbow,1 reflector cap,2 webbed hangers,1 coupler 180 DEGREE SWAGED ELBOW KIT 2 x JS-0508-JZ 2 x 90 degree elbow kits-3 webbed hangers,2 couplers FRESH AIR INTAKE WALL HOOD JS-0532-VC Illfffii���1 \ ROOF VENT TERMINAL 102 mm(4") JA-0530-XX \ ROOF VENT TERMINAL 152 mm(6") JA-0531-XX WALL VENT TERMINAL 102 mm(4") JA-0526-XX L ��11Gi, 11�A t�I� >-� WALL VENT TERMINAL 152 mm(8") JA-0529-XX `� ILLSt�)�\I,'?�°�� FLUE VENT TEE JA-0514-XX GC i�h! " "9 (102 mmxt02 mmx152 mm)(4"x4"x6") '''''''N, --��A j � COUPLING KIT FOR TEE JA-0516-SW \ , �����;::: TRU-TEMP THERMOSTAT JM-0150-XX i1i THERMOSTAT 24 VOLT JS-0569-WR ���nnn,,, THERMOSTAT 120 VOLT JL-0772-XX CB B.. Y/ - - ,� 24V THERMOSTAT OPTION: 2 TO 7 HEATERS PER THERMOSTAT JM-0303-KT CANADA: TYPE 1 HOSE GAS CONNECTOR 45,000 to 155,000 JL-0771-RC 175,000 8 200,000 JL-0771-RB USA: FLEXIBLE GAS CONNECTOR . 1/2"x 24" 45,000 to 155,000 JL-0771-XX 3/4'x 24" 175,000&200,000 JL-0771-ZZ AP-SSJS-BX-04C 5 IQ SD RI.:<C RD.SEP 2005 BA • APPROVED MINIMUM CLEARANCES TO COMBUSTIBLES SUSPENDED AT AN ANGLE SUSPENDED HORIZONTALLY MODEL UP TO 45 DEGREES D E F G A B C IQ 200 6" I" 57" 68" 6.5" 22" 68" IQ 175 4.5" I" 47" 68" 5.5" 20" 68" IQ 155 3.5" 1" 44" 64" 5.5" 19" 64" IQ 130 3.3" I" 35" 56" 4.5" 11" 60" IQ 110 2" I" 26" 54" 3.5" 10" 54" IQ 100 6" I" 57" 68" 6.5" 22" 68" IQ 80 1.75" I" 23" 38" 3" 6" 36" IQ 60 1.5" i " 17" 34" 2.5" 5.5" 34" IQ 45 2.25" I" 24" 32" 2.75" 7" 32" SUSPENDED AT AN ANGLE UP TO 45 DEGREES SUSPENDED HORIZONTALLY D A 1 v w y I g ._ L. 1 C G AP-SSJSBA-04C 6 IQ SD BL'.JC BD'.SEP 2006 BA TYPICAL HANGER & SUPPORT SPACING RECOMMENDATIONS 29947 mm 2A19 mm (I 1HG I U161 52 mm 161 U O 0 s0 0 e © O • G \O a B I. 4 ew Q Burner As6embl9 MI— O2 Flange Adapter O Flanged Tube ® Swaged Tube OFlue Vent erminal ® End Plate Hanger ]® Plate Hanger lift" /Me 0 Hanging Chams 1 - theubl flange�r/ the tuba 64 m (2.5 0 FOCUS Shied ReleUOr •1 and the hange/s plate ® Redactor Siabiliier must be 64 mm Mme REFLECTOR STABILIZER ELBOW/WEBBED HANGER INSTALLATION CI P 0 0 a 6 `per do °�► ' Sc O 44, 4 444 • /-1/4-- 4 /0, 4? 0 • O JS-0508-JZ 1. Webbed Hanger 4. Webbed Hanger Flange to mount UNDER • 2. Reflector Cap the next Reflector 3. Webbed Hanger Flange UNDER Reflector 5. 90°Elbow - 6. Tube/ Elbow Coupler APSSIS-BF+HC 7 IQ SD RL:1C RD'.Slip 21106 BA COMPONENT DESCRIPTION IGNITION DIRECT SPARK MODULE -HONEYWELL -NATURAL GAS 8.17 mbar(3 COMBINATION GAS A"W.C.)AT MANIFOLD VALVE HONEYWELL 24 VOLT -PROPANE 24.9 mbar (10"W.C.)AT MANIFOLD REFLECTORS EXTEND 25.4 mm(1")BELOW BOTTOM OF TUBE SURFACE REFLECTORS REFLECTORS ARE CLOSED AT START AND END OF EACH STRAIGHT RUN OF TUBES BY MEANS OF END PLATE HANGERS HEATER TUBE(S) THE FIRST SECTION IS 3040 mm(10')LONG, 102 mm(4")DIAMETER,.95 mm(16 GA.) ALUMINIZED STEEL SWAGED ONE END 47,000 to 162,750 Kj EACH ADDITIONAL SECTION IS 3040 mm(10')LONG, 102 mm(4")DIAMETER, .95 mm (45 to 155 MBTUH) (16 GA.)HOT ROLLED STEEL WITH EMISSIVE COATING SWAGED ONE END THE FIRST SECTION IS 3040 mm(10')LONG,102 mm(4")DIAMETER,.95 mm(16 GA.) HEATER TUBE(S) ALUMATHERM SWAGED ONE END 184,700 8210,000 Kj THE SECOND SECTION IS 3040 mm(10') LONG, 102 mm (4") DIAMETER, .95 mm (16 GA.)ALUMINIZED STEEL SWAGED ONE END (175&200 MBTUH) EACH ADDITIONAL SECTION IS 3040 mm(10')LONG, 102 mm(4")DIAMETER, .95 mm (16 GA.)HOT ROLLED STEEL WITH EMISSIVE COATING SWAGED ONE END ONE WEBBED HANGER SUPPORTS EACH 3040 mm (10') OF TUBE, EXCEPT THE HANGERS FIRST AND LAST TUBES WHICH UTILIZE ONE WEBBED HANGER AND ONE PLATE HANGER AT EACH END. COUPLING KIT ALUMINIZED STEEL COUPLER 90 DEGREE ELBOW 102 mm(4")DIAMETER, .95 mm(16 GA.)ALUMINIZED STEEL,216 mm(8 A")CENTRE RADIUS SWAGED ONE END ELBOWS 180 DEGREE ELBOW 102 mm (4") DIAMETER, .95 mm (16 GA.)ALUMINIZED STEEL, 216 mm(8 Al CENTRE RADIUS (ASSEMBLY OF TWO 90 DEGREE ELBOW KITS) BURNER HOUSING BOTTOM FOLDS AWAY,PROVIDING ACCESS FROM TWO SIDES,END AND BOTTOM INCORPORATES EFFECTILE CERAMIC BURNER HEAD WITH BURNER MINIMUM OF 835 FLAME PORTS COMPLETE WITH OPERATION STATUS INDICATOR LIGHTS TRANSFORMER 120/24VAC;20VA SAFETY SWITCHES TWO SEPARATE AIR PRESSURE SWITCHES SENSE ADEQUATE COMBUSTION AIR AND BLOCKED FLUE STATUS INDICATOR GREEN:CALL FOR HEAT;YELLOW:IGNITION TRIAL;RED:FLAME ESTABLISHED LIGHTS COMBUSTION AIR COMBUSTION AIR DUCTED DIRECTLY TO INTAKE OF BLOWER INFRASAVE TRU-TEMP (24V) SET BACK THERMOSTAT WITH RADIANT 8 AMBIENT SENSORS,AND AUTOMATIC UNOCCUPIED SETBACK MODE THERMOSTAT 24V THERMOSTAT OPTIONS NOTE: MULTIPLE HEATERS PER 24V THERMOSTAT REQUIRE TRANSFORMER/ RELAY KIT JM-0303-KT LINE VOLTAGE THERMOSTAT TERMINAL BLOCK ALL WIRING CONNECTIONS BY MEANS OF COMMON TERMINAL BLOCK; JUMPER: FOR 120V THERMOSTAT;REMOVE FOR 24V THERMOSTAT ELECTRICAL CORD 1220 mm (4') LENGTH 16/3 ELECTRICAL SUPPLY CORD WITH 3 PIN GROUNDED PLUG UP.SSiS•BX.aC 8 Ip NE)RL:4C • R0:SEP 200( BA TRANE® 4TTM3048-SUB-105.02 TAG: SUBMITTAL 4 Ton Split System Cooling — 1 Phase 4TTM3048A E914 Product Specifications / OUTDOOR UNIT OO OO 4TTM3048A1000B :.:40,11r00)„,,,,,����' n, POWER CONNS.—V/PH/HZ Oa 208/230/1/60 % �������������Lr /117�//�� MIN. BRCH.CIR.AMPACITY 29 x�VA�11�����i�/ �� BR.CIR.PROT. RTG.- MAX.(AMPS) 50 r\ \�\ •.• COMPRESSOR c. _,...--.E-..........:—.‘,„.1. : NO. USED-NO.SPEEDS 1 - 1 xe vx VOLTS/PH/HZ 208/230/1/60 ELECTRICAL AND REFRIGERANT r COMPONENT1CLEARANCES. i R.L.AMPS O-L.R.AMPS 21.8- 117 '/ \ FACTORY INSTALLED - � �r///4lit�V∎ ,-� -• START COMPONENTS O NO of� �1iIIII INSULATION/SOUND BLANKET NO yf �����������I�`1���\ ' COMPRESSOR HEAT NO OMIT SHOULD HE PLACED so ROOF +. 'sr.:,aa N:r•:-�::>' /) OUTDOOR FAN PROPELLER RUN-OFF RATER DOES NOT POUR N'•.•u:•.•:e•••-' DIRECTLY�z UNIT, vniLSneoLiu E DIA. (IN.)-NO.USED 23- 1 SURROUNDING SHRUBBERY ON TWO SIDES. TYPE DRIVE- NO.SPEEDS DIRECT - 1 OTHER TWO SIDES UNRESTRICTED. CFM © 0.0 IN.W.G.0 3900 -_.-.-...-..___________-...-____..._. NO. MOTORS - HP 1 - 1/3 MOTOR SPEED R.P.M. 1115 VOLTS/PH/HZ 200/230 ue DIA. HOLE IN CONTROL F.L.AMPS 1 7 Box BOTTOM FOR EL ELECTRICAL OUTDOOR COIL FACE AREA(SO. FT.) 14.54 REFRIGERANT I-SIB DIA. ROLE IN CONTROL LBS.— R-410A O.D. UNIT) s 800 BOTTOM FOR LOW VOLTAGE h �,I ( )O 4 LBS., 13 OZ. Pa.HO FACTORY SUPPLIED YES i� LINE SIZE -IN.O.D.GAS© 7/8 LIOUID LINE SERVICE LINE SIZE- IN.O.D.La© 3/8 VALVE. RAZ I.O. FEMALE BRAZE CONNECTION E CHARGING SPECIFICATION-See Charging Section in Service Facts WITH EI T• SAE FLARE P R E S S U R E r e v r l n lies DIMENSIONS H X W X D x CRATED (IN.) 32-3/8 x 79-3/4 x 30-1/2 0114 i :13• ....._......-.�.._ ...__ WEIGHT --_..—_ SHIPPING (LBS.) 191 SUCTION LINE SERVICE VALVE -A" 1.0. NET(LBS.) 168 'SIB FEMALE BRAM CONNECTION WITH vP 51/4 SAE EL ARE PRSSURE TAP FIRING BASE 3 O Oedilied in accordance with 1ne Air-Source Unitary Ay—conditioner Equipment ceNliratian program, which is based on ARI standard 210/240. 0 Rated in accordance wth ARI standard 270. OO Calculated in accordance wAh Natl.Elec.Codes.Use only HACK circuit breakers or fuses. O Standard Air—Dry Coil—Outdoor O This value approximate.For more precise value see unit nameplate. E Max,linear length 6011.;Max.lift-Suction 60 ft.;Max lilt-Liquid 6011. For greater length consult refrigerant piping software Pub.No.32-3312-0• I•denotes latest revisionl. OO This value shown for compressor RLA on the unit nameplate and on Nis specltcation sheet is used to compute mirAmum branch circuit ampaciry and max.luse sue.The value shown is the branch circuit selection current. O' No means no start components.Yes means quick start Oil components.PTC means poslrve temperature coefficient Nader. ©2011 Trane • Mechanical Specification Options General Compressor The 4TTM3 is fully charged from the The Climatuff®compressor features factory for up to 15 feet of piping for the internal over temperature and pressure smallest rated combination. Other protection and total dipped hermetic combinations will require additional motor. charge.This unit must be applied with Time Delay Relay a TXV equipped indoor unit.This unit is designed to operate at outdoor ambi- The time delay relay prevents conv- ent temperatures as high as 115°F. pressor short cycling and improves Cooling capacities are matched with a startability and reliability. wide selection of air handlers and Condenser Coil furnace coils that are A.H.R.I.certified. The outdoor coil provides low airflow The unit is certified to UL 1995. Exterior resistance and efficient heat transfer. • is designed for outdoor application. Low Ambient Cooling Manual Charge AssistTM As manufactured, this unit has a A Trane exclusive, the manual charge cooling capability to 60°F The addition assist helps ensure the proper refriger- of an evaporator defrost control permits low ambient cooling to 30° F.The ant charge, providing ideal perfor- addition of a low ambient kit allows mance and efficiency. operation down to 0° F. Casing Accessories The unit is constructed of heavy gauge, Thermostats— Cooling only and G90 galvanized steel and painted with heat/cooling (manual and automatic a weather-resistant powder paint on changeover). Sub-base to match the top, base & coil guard, prepaint on thermostat and locking thermostat all other panels. cover. Refrigerant Controls Evaporator Defrost Control—See Refrigeration system controls include Low Ambient Cooling. condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A field installed liquid - line drier is shipped with the unit. \NT ER YEt. .A':..a CERTIFIED.. WW/Sm9AC .,,...,i i„ e, e, urw swe.e ZIORNI US LIFTED 08/11 TRANE Trane Trane has a policy of continuous product and product data improvement and it reserves the right to change 6200 Troup Highway design and specifications without notice. Tyler,TX 75707 r¢moffal Slags/ ,i--d TXC-B-SPEC-1 C H E A T I N G & A I R C O N D I T I O N I N G TAG: SPECIFICATION 1-1/2 - 5 ton Comfort Co!IsmM, Split System Aluminum Heat Pump / Cooling Coils Cased Upflow/Downflow Horizontal 4TXC Series Coils OG(I FLANG( 0 ^I r—Ism i95116 Ire RCN GAS LIPID(a.an. I-la A II' )/IP11PP SIRT DRAIN 1-IIn6 3 IWri11 PIWGIO �M POSITION `�I PRIMARY DRAIN I, ant n =�1 FOR HORIZONTAL• 6 POSITION IDmml r DRAIN 11'0116 3/4'NIT POSITION RAMP DRAIN Ia1. kilt 3IOR NIT PP1 OP „ ` -3n6 „,,,, Raft"! 1-0116 3-SID I.)rl 10-ue - C OPINING a RRUru Eru1 B 4TXCA018BC3NCB 4TXCB0253C3HCB 4TXCB032BC3HCB 4TXCC037BC3HCB 4TXCB048BC3HCB 47X000448C3HCB 47%CCOBOBL3HCB MODEL 4TXCA024BC3HCB 4TXC8038C3HCB 4T%CB036BC3HCB 4TXCC043BC3HC13 4T%CC0498C3F1CB 4TXCB0428C3HCB WEIGHT ILBS.1 34 38 _ 45 48 49 51 65 REFRIGERANT CONTROL 1XV (NON-BLEED/ HEIGHT -A- WI 22-5/8 11-5/8 1 225/8 22-5/8 26-1/8 26-1/8 1 30-1/16 OVERALL WIDTH -B- IIN.I 14.1/2 17-1/2 21 17-1/2 21 OPENING WIDTH -C- IIN3 13.1/2 _ 16-1/2 20 16-1/2 20 TOP OPENING "D' 12-3/4 15-3/4 19-1/4 15-3/4 19-1/4 GAS CONNECTION 314 BRAZE 1/8 BRAZE I-I/8 BRAZE R410-A GAS REDUCER 5/8' X 3/4' 15/8' X 3/4* 1025 011111 3/4' X 7/8• 7/8' X I-I/8' LIQUID CONNECTION 5/16 BRAZE 3/8 BRAZE MATCHED FURNACE WIDTH I4-I/2 11-1/2 21 17-1/2 21 (NO ADAPTER REQUIRED) DRAIN PAN PLASTIC * Reducer supplied with R-410A models ©2013 American Standard Heating&Air Conditioning All Rights Reserved Mechanical Specifications General Accessories Upflow, Downflow, or Horizontal coils shall be designed for cooling and Evaporator Defrost Control installed on coil for heat pump applications. The coil shall be 3/8" seamless aluminum tub- lower ambient operating conditions. ing mechanically bonded to aluminum plate fin. Non-Bleed Expansion Valve Kits for use with Refrigerant for the TXC coils shall be controlled with factory installed R410A refrigerant systems. Non-Bleed TXV refrigerant control. Refrigerant connections are brazed fittings with an additional Schrader Valve for system service. The coil cabinet shall have a removable front and interior access panel for evaporator coil entering air surface cleaning. The coil includes a drain pan with drain connections for vertical or hori- zontal operation and a horizontal auxiliary drain pan. These coils are A.R.I.certified with American Standard's matching con- densing units. PRODUCT SPECIFICATIONS --- SPLIT SYSTEM HEAT PUMP/COOLING COMFORT"' COILS CASED UPFLOW/ DOWNFLOW/ HORIZONTAL 4TXCA018BC3HCB 4TXCA024BC3HCB 4TXCB025BC3HCB 4TXCB031BC3HCB 4TXCB032BC3HCB INDOOR COIL-Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows/E.P.I. 2/18 2/18 3/14 3/14 3/14 Face Area(sq.ft.) 3.50 4.00 3.50 5.00 5.00 Tube Size 3/8 3/8 3/8 3/8 3/8 Refrigerant Control(No Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV internal check valve) Drain Conn.Size(in.) 314 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections -See Outline Drawings- REFRIGERANT R-410A R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED BRAZED Line Size-Gas(in.) 1/2' 5/8* 5/8' 3/4 3/4' Line Size--Liquid(in.) 1/4 5/16 5/16 5/16 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D H X W X D Crated(H xW x D) 15-1/2x17-1/2x26-1/2 18-1/2x17-1/2x26-1/2 16-1/2 x 20-1/2 x 26-1/2 16-1/2x20-1/2x26.1/2 22-3/4x20-1/2x26-1/2 Uncrated -See Outline Drawings- WEIGHT(Ibs) Shipping--Net 36/34 36/34 40/38 40/38 48/45 'Reducer supplied with R-410A models [1]These indoor coils are A.R.I.certified with various split system air conditioners and heat pumps(A.R.I.Standard 210/240). Refer to the split system product data guides for performance data. • PRODUCT SPECIFICATIONS --- SPLIT SYSTEM HEAT PUMP/COOLING COMFORTTM COILS CASED UPFLOW/ DOWNFLOW/ HORIZONTAL 4TXCB036BC3HCB 4TXCC037BC3HCB 4TXCB042BC3HCB 4TXCC043BC3HCB 4TXCC044BC3HCB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Rows/EP.I. 3(14 3/14 3/14 3/14 3(14 Face Area(sq.ft.) 5.00 5.00 5.00 5.00 6.00 Tube Size 3/8 3/8 3/8 3/8 3/8 Refrigerant Control(No Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV internal check valve) Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections -See Outline Drawings- REFRIGERANT R-410A R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED BRAZED Line Size--Gas(in.) 3/4' 3/4' 3/4' 3/4' 7/8' Line Size--Liquid(in.) 3/8 5116 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D H X W X D H X W X D Crated(H x W x D) 22-3/4 x 20-1/2 x 26-1/2 22-3/4 x 24 x 26-1/2 22-3/4 x 20-1/2 x 26-1/2 22-3/4 x 24 x 26.1/2 28-1/4 x 24 x 26-1/2 Uncrated -See Outline Drawings- WEIGHT(lbs) Shipping--Net 48/45 51/48 48/45 51/48 55/51 4TXCB048BC3HCB 4TXCC049BC3HCB 4TXCCO60BC3HCB INDOOR COIL--Type PLATE FIN PLATE FIN PLATE FIN Rows/FRI. 3/14 3/14 3/14 Face Area(sq.ft.) 6.00 6.00 7.00 Tube Size 3/8 3/8 3/8 Refrigerant Control(No Non-Bleed TXV Non-Bleed TXV Non-Bleed TXV internal check valve) Drain Conn.Size(in.) 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections -See Outline Drawings- REFRIGERANT R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED Line Size--Gas(in.) 7/8' 7/8' 7/8' Line Size--Liquid(in.) 3/8 3/8 3/8 DIMENSIONS(in.) H X W X D H X W X D H X W X D Crated(H x W D) 28-1/4 x 20-1/2 x 26-1/2 28-1/4 x 24 x 26-1/2 31-1/2 x 24 x 26-1/2 Uncrated -See Outline Drawings- WEIGHT(lbs) Shipping--Net 51/49 55/51 69/65 'Reducer supplied with R-410A models [1]These indoor coils are A.R.I.certified with various split system air conditioners and heat pumps(A.R.I.Standard 210/240). Refer to the split system product data guides for performance data. PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW(CFM)VS.PRESSURE DROP ACROSS WET COIL PRESSURE DROP (INCHES OF WATER COLUMN) MODEL .05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4TXCA018BC3HCB 360 545 690 820 930 1040 1135 1230 4TXCA024BC3HCB 360 545 690 820 930 1040 1135 1230 4TXCB025BC3HCB 310 515 700 865 1020 1170 1310 1450 4TXCB031BC3HCB 4TXCB032BC3HCB 480 690 860 1005 1130 1250 1360 1460 4TXCB036BC3HCB 4TXCB042BC3HCB 4TXCB048BC3HCB 470 680 840 980 1110 1220 1330 1425 • 4TXCC037BC3HCB 630 900 1105 1280 1440 1520 1710 1830 4TXCC043BC3HCB 4TXCC044BC3HCB 675 970 1200 1390 1560 1715 1860 2000 4TXCC049BC3HCB 4TXCCO6OBC3HCB 680 965 1190 1375 1540 1685 1820 1950 Since American Standard Heating&Air Conditioning has a policy of continuous product end product data improve- Library Unitary merit,it reserves the right to change specifications and Product Section Coils design wdhout notice. Product Coil Technical Literature-Printed in U.S.A. F L Model TXC-B C \�I US Literature Type Specification Sequence American Standard Date 09/13 Healing swo File No. TXC-B-SPEC-1C 6200 Troup Air Conditioning op Highway Tyler,TX 75707 Intertek Supersedes TXC-B-SPEC-1B COMcheck Software Version 3.9.3 Mechanical Compliance Certificate 2010 Oregon Energy Efficiency Specialty Code Section 1 : Project Information Project Type:Alteration Project Title:Welby Car Care Construction Site: Owner/Agent: Designer/Contractor: 3654 Kathryn Ave Scott Carver Brian Tiller Springfield,OR 97477 PO BOX 936 Jco Heating Folsom,CA 95630 5729 Main street#233 1-503-545-4121 Springfield,OR 97478 541-746-7065 Brian @jcohvac.com Section 2: General Information Building Location(for weather data): Eugene,Oregon Climate Zone: 4c Section 3: Mechanical Systems List Quantity System Tvpt&D.escriptLoxi 1 HVAC System 1 (Single Zone): Heating: 1 each-Central Furnace,Gas,Capacity=4 kBtu/h Proposed Efficiency=95.00%Et,Required Efficiency=80.00%Et Cooling: 1 each-Split System,Capacity=4 kBtu/h,Air-Cooled Condenser Proposed Efficiency= 13.00 SEER, Required Efficiency=13.00 SEER Fan System: None 1 HVAC System 2(Single Zone): Heating: 1 each-Radiant Heater,Gas,Capacity=5 kBtu/h No minimum efficiency requirement applies Fan System: None 1 HVAC System 4(Single Zone): Heating: 1 each-Radiant Heater,Gas,Capacity=7 kBtulh No minimum efficiency requirement applies • Fan System: None 1 HVAC System 5(Single Zone): Heating: 1 each-Radiant Heater,Gas,Capacity= 10 kBtu/h No minimum efficiency requirement applies Fan System: None 1 HVAC System 6(Unknown): Heating: 1 each-Unit Heater,Gas,Capacity=8 kBtu/h Proposed Efficiency=80.00%Ec, Required Efficiency=80.00%Ec Fan System: None Section 4: Requirements Checklist In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met.Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Requirements Specific To: HVAC System 1 : 1. Equipment meets minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) Project Title: Welby Car Care Report date: 06/24/14 Data filename:C:\Userslbrian_tablet\Documents\COMcheck\Welbys Car Care.cck Page 1 of 6 • 2. Equipment meets minimum efficiency: Split System: 13.00 SEER ❑ 3. Energy recovery ventilation systems. Individual fan systems that have both a design supply air capacity of 5,000 cfm or greater and a minimum outside air supply of 70 percent or greater of the design supply air quantity have an energy recovery system. Exception(s): ❑ Where energy recovery systems are prohibited by the International Mechanical Code. ❑ Systems serving spaces that are not cooled and are heated to less than 60°F. ❑ Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. ❑ Type 1 kitchen exhaust hoods. ❑ Cooling systems in climates with a 1-percent cooling design wet-bulb temperature less than 64°F(18°C). ❑ Systems requiring dehumidification that employ series-style energy recovery coils wrapped around the cooling coil when the evaporative coil is located upstream of the exhaust air stream. ❑ Systems exhausting toxic,flammable,paint exhaust,corrosive fumes,or dust. ❑ Laboratory fume hood systems that include qualifying features. Plans reference page/section: N/A Requirements Specific To: HVAC System 2 : ❑ 1. Hydronic system controls.Hydronic systems of at least 300,000 Btu/h design output capacity supplying heated and chilled water to comfort conditioning systems include controls that meet the requirements of Section 503.4.3. Plans reference page/section: N/A Requirements Specific To: HVAC System 4 : ❑ 1. Hydronic system controls.Hydronic systems of at least 300,000 Btu/h design output capacity supplying heated and chilled water to comfort conditioning systems include controls that meet the requirements of Section 503.4.3. Plans reference page/section: N/@ Requirements Specific To: HVAC System 5 : ❑ 1. Hydronic system controls. Hydronic systems of at least 300,000 Btu/h design output capacity supplying heated and chilled water to comfort conditioning systems include controls that meet the requirements of Section 503.4.3. Plans reference page/section: N/A Requirements Specific To: HVAC System 6 : • 1. Equipment meets minimum efficiency: Unit Heater(Gas): 80.00%Ec ❑ 2. Energy recovery ventilation systems. Individual fan systems that have both a design supply air capacity of 5,000 cfm or greater and a minimum outside air supply of 70 percent or greater of the design supply air quantity have an energy recovery system. Exception(s): ❑ Where energy recovery systems are prohibited by the International Mechanical Code, ❑ Systems serving spaces that are not cooled and are heated to less than 60°F. Li Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. ❑ Type 1 kitchen exhaust hoods. ❑ Cooling systems in climates with a 1-percent cooling design wet-bulb temperature less than 64°F(18°C). ❑ Systems requiring dehumidification that employ series-style energy recovery coils wrapped around the cooling coil when the evaporative coil is located upstream of the exhaust air stream. ❑ Systems exhausting toxic,flammable,paint exhaust,corrosive fumes,or dust. ❑ Laboratory fume hood systems that include qualifying features. Plans reference page/section: N/A Generic Requirements: Must be met by all systems to which the requirement is applicable: • 1. Calculation of heating and cooling loads.Design loads are determined in accordance with the procedures described in the ASHRAE/ACCA Standard 183.Alternatively,design loads have been determined by an approved equivalent computation procedure. ❑ 2. Cooling equipment economizers:The total capacity of all cooling equipment without economizers must be less than 240 kBtu/h.This project lists 4 kBtu/h capacity without economizers.That portion of the equipment serving dwelling units and guest rooms is not included in determining the total capacity of units without economizers. Plans reference page/section: N/A Project Title: Welby Car Care Report date: 06/24/14 Data filename: C:\Users\brian_tablet\Documents\COMcheck\Welbys Car Care.cck Page 2 of 6 • 3. Equipment and system sizing.Heating and cooling equipment and systems capacity do not exceed the loads calculated in accordance with Section 503.2.1. Plans reference page/section: • 4. HVAC Equipment Performance Requirements.Reported efficiencies have been tested and rated in accordance with the applicable test procedure.The efficiency has been verified through certification under an approved certification program or,if no certification program exists,the equipment efficiency ratings are supported by data furnished by the manufacturer. ✓ 5. Thermostatic Controls.The supply of heating and cooling energy to each zone is controlled by individual thermostatic controls that respond to temperature within the zone. Plans reference page/section: ID 6. Heat pump supplementary heat.Heat pumps having supplementary electric resistance heat have controls that,except during defrost, prevent supplementary heat operation when the heat pump can meet the heating load. Plans reference page/section: N/A 7. Set point overlap restriction.Where used to control both heating and cooling,zone thermostatic controls provide a temperature range or deadband of at least 5°F(2.8°C)within which the supply of heating and cooling energy to the zone is capable of being shut off or reduced to a minimum. Plans reference page/section: ✓ 8. Optimum Start Controls.Each HVAC system has controls that vary the start-up time of the system to just meet the temperature set point at time of occupancy. Plans reference page/section: ✓ 9. Off-hour controls.Each zone is provided with thermostatic setback controls that are controlled by either an automatic time clock or programmable control system. Plans reference page/section: • 10.Shutoff damper controls.Both outdoor air supply and exhaust are equipped with not less than Class I motorized dampers. Exception(s): • ❑ Gravity dampers shall be permitted for outside air intake or exhaust airflows of 300 cfm or less. Plans reference page/section: N/A • 11.Freeze Protection and Snow melt system controls.Freeze protection systems,such as heat tracing of outdoor piping and heat exchangers,including self-regulating heat tracing,include automatic controls capable of shutting off the systems when outdoor air temperatures meet code criteria. Plans reference page/section: N/A D 12.Separate air distribution systems.Zones with special process temperature requirements and/or humidity requirements are served by separate air distribution systems from those serving zones requiring only comfort conditions;or shall include supplementary control provisions so that the primary systems may be specifically controlled for comfort purposes only. Exception(s): ❑ [503.2.4.8+]Zones requiring only comfort heating or comfort cooling that are served by a system primarily used for process temperature and humidity control. Plans reference page/section: N/A ❑ 13.Humidity control.If a system is equipped with a means to add or remove moisture to maintain specific humidity levels in a zone or zones,a humidity control device is provided. Plans reference page/section: N/A ❑ 14.Humidity control.Where a humidity control device exists it is set to prevent the use of fossil fuel or electricity to produce relative humidity in excess of 30 percent.Where a humidity control device is used for dehumidification,it is set to prevent the use of fossil fuel or electricity to reduce relative humidity below 60 percent. Exception(s): • Hospitals,process needs,archives,museums,critical equipment,and other non-comfort situations with specific humidity requirements outside this range. Plans reference page/section: N/A • 15.Humidity control.Where a humidity control device exists it is set to maintain a deadband of at least 10%relative humidity where no active humidification or dehumidification takes place. Exception(s): ❑ Heating for dehumidification is provided with heat recovery or heat pumping and the mechanical cooling system efficiency is 10 percent higher than required in section 503.2.3, HVAC equipment performance requirements. Project Title:Welby Car Care Report date: 06/24/14 Data filename: C:\Userslbrian_tablet\Documents\COMcheck\Welbys Car Care.cck Page 3 of 6 Plans reference page/section: N/A • 16.Ventilation.Ventilation,either natural or mechanical,is provided in accordance with Chapter 4 of the International Mechanical Code. Where mechanical ventilation is provided,the system has the capability to reduce the outdoor air supply to the minimum required by Chapter 4 of the International Mechanical Code. Plans reference page/section: N/A • 17.Demand controlled ventilation(DCV).DCV is required for spaces larger than 500 ft2 for simple systems and spaces larger than 150 ft2 for multiple zone systems. Exception(s): u Systems with energy recovery complying with Section 503.2.6 LI Spaces less than 750 ft2(69.7 m2)where an occupancy sensor turns the fan off,closes the ventilation damper,or closes the zone damper when the space is unoccupied. Plans reference page/section: NA ❑ 18.Kitchen hoods.Kitchen makeup is provided as required by the Oregon Mechanical Specialty Code. Exception(s): Li Where hoods are used to exhaust ventilation air that would otherwise be exhausted by other fan systems. LI Kitchen exhaust systems that include exhaust air energy recovery complying with section 503.2.6. Plans reference page/section: N/A u 19.Enclosed parking garage ventilation controls. In Group S-2,enclosed parking garages used for storing or handling automobiles employs automatic carbon monoxide sensing devices. Plans reference page/section: N/A • 20.Duct and plenum insulation and sealing.All supply and return air ducts and plenums are insulated with the specified insulation.When located within a building envelope assembly,the duct or plenum is separated from the building exterior or unconditioned or exempt spaces by a minimum of R-8 insulation.All ducts,air handlers and filter boxes are sealed.Joints and seams comply with Section 603.9 of the International Mechanical Code. • 21.Low-pressure duct systems.All longitudinal and transverse joints,seams and connections of low-pressure supply and return ducts are securely fastened and sealed with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric systems or tapes installed in accordance with the manufacturer's installation instructions. Exception(s): LI Continuously welded and locking-type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification. Plans reference page/section: N/A 22.Medium-pressure duct systems.All ducts and plenums designed to operate medium-pressure are insulated and sealed in accordance with Section 503.2.7. Pressure classifications specific to the duct system are clearly indicated on the construction documents. Plans reference page/section: ❑ 23.High-pressure duct systems. Ducts designed to operate at high-pressure are insulated and sealed in accordance with Section 503.2.7. In addition,ducts and plenums are leak-tested in accordance with the SMACNA HVAC Air Duct Leakage Test Manual. Plans reference page/section: N/A • 24.Piping Insulation.All pipes serving space-conditioning systems(hot water piping for heat systems,chilled water,refrigerant,and brine piping systems,and steam piping)are insulated as specified by this section. jot 25Air system balancing.Each supply air outlet and zone terminal device is equipped with means for air balancing in accordance with the requirements of IMC 603.17. Discharge dampers intended to modulate airflow are prohibited on constant volume fans and variable volume fans with motors 10 horsepower. Plans reference page/section: • 26.Hydronic system balancing.Individual hydronic heating and cooling coils are equipped with means for balancing and pressure test connections. Plans reference page/section: N/A • 27.Manuals.The construction documents require that an operating and maintenance manual be provided to the building owner by the mechanical contractor.See long description for specifications. Plans reference page/section: • 28.Air System Design and Control.Each HVAC system having a total fan system motor nameplate hp exceeding 5 hp meets the provisions of Sections 503.2.10.1 through 503.2.10.2. Project Title:Welby Car Care Report date: 06/24/14 Data filename: C:\Users\brian_tablet\Documents\COMcheck\Welbys Car Care.cck Page 4 of 6 Plans reference page/section: N/A • 29.Allowable fan floor horsepower. Each HVAC system at fan system design conditions does not exceed the allowable fan system motor nameplate hp(Option 1)or fan system bhp(Option 2)as shown and calulated in requirement details. Exception(s): O Hospital and laboratory systems that utilize flow control devices on exhaust and/or return to maintain space pressure relationships necessary for occupant health and safety or environmental control shall be permitted to use variable volume fan power limitation. o Individual exhaust fans with motor nameplate horsepower of 1 hp or less. Plans reference page/section: N/A • 30.Motor nameplate horsepower.For each fan,the selected fan motor is no larger than the first available motor size greater than the brake horsepower(bhp). Exception(s): For fans less than 6 bhp,where the first available motor larger than the brake horsepower has a nameplate rating within 50 percent of the bhp,selection of the next larger nameplate motor size is allowed. LI For fans 6 bhp and larger,where the first available motor larger than the bhp has a nameplate rating within 30 percent of the bhp, selection of the next larger nameplate motor size is allowed. Plans reference page/section: N/A • 31.Large Volume Fan Systems.Fan systems over 8,000(7 m3/s)cfm without direct expansion cooling coils that serve single zones reduce airflow based on space thermostat heating and cooling demand.A two-speed motor or variable frequency drive reduces airflow to a maximum 60 percent of peak airflow or minimum ventilation air requirement as required by Chapter 4 of the International Mechanical Code,whichever is greater. Exception(s): o Systems where the function of the supply air is for purposes other than temperature control,such as maintaining specific humidity levels or supplying an exhaust system. Plans reference page/section: N/A • 32.AII air-conditioning equipment and air-handling units with direct expansion cooling and a cooling capacity at ARI conditions greater than or equal to 110,000 Btu/h that serve single zones have their supply fan operation controlled according to code specific requirements. Exception(s): LI Systems where the function of the supply air is for purposes other than temperature control,such as maintaining specific humidity levels or supplying an exhaust system. Plans reference page/section: N/A • 33.Series fan-powered terminal unit fan motors. Fan motors for series fan-powered terminal units are electronically-commutated motors and have a minimum motor efficiency of 70 percent when rated in accordance with NEMA Standard MG 1-2006 at full load rating conditions. Plans reference page/section: N/A • 34.Heating outside a building.Systems installed to provide heat outside a building are radiant systems.Such heating systems are controlled by an occupancy sensing device or a timer switch,so that the system is automatically deenergized when no occupants are present. Plans reference page/section: NIA • 35.Hot Gas Bypass Limitation.For cooling systems<=240 kBtu/h,maximum hot gas bypass capacity is no more than 50%total cooling capacity. Plans reference page/section: N/A Section 5: Compliance Statement Compliance Statement The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application.The proposed mechanical alteration project has been designed to meet the 2010 Oregon Energy Efficiency Specialty Code,Chapter 8,requireme s in COMcheck Version 3.9.3 and to comply with the mandatory requirements in the Requirements Checklist. PPe$∎ a .4 ✓f 06/717/t/ Name-Title Signature Date 6: Post Construction Compliance Statement Project Title:Welby Car Care Report date: 06/24/14 Data filename: C:\Users\brian_tablet\Documents\COMcheck\Welbys Car Care.cck Page 5 of 6 • HVAC record drawings of the actual installation,system capacities,calibration information,and performance data for each equipment provided to the owner. 2 HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. © Written HVAC balancing and operations report provided to the owner. The above post construction requirements have been completed. Principal Mechanical Designer-Name Signature Date Project Title: Welby Car Care Report date: 06/24/14 Data filename:C:\Users\brian_tablet\Documents\COMcheck\Welbys Car Care.cck Page 6 of 6