Loading...
HomeMy WebLinkAboutBuilding Miscellaneous 2014-6-24 FE' Compressive Strength of Masonry Prisms TEWINGaINSPETION,ler. G•c,.h°k°I a=° °n s-n"' Geotechrtical&Construction services ASTM C 1314 CLIENT Mr.Jeff Givens PROJECT IP–UPS Electric/ DATE 06-24-14 International Paper, Inc. Battery Room PROJECT NO. 2147043 801 42ntl Street 801 42nd Street ,REPORT NO. 9636 Springfield,Oregon 97478 Springfield, Oregon BP NO. 811-SPR2013-02528 DATE CONSTRUCTED 05-27-14 DATE RECEIVED 05-29-14 • DATE GROUTED N/A FEI REP. N/A PRISM I.D. 8"x 8"x 16"smooth face SOLID HOLLOW XXX TIME -- DESIGN(F'M) 1500 psi WEATHER/TEMP. Showers/58° SPECIMEN STORAGE ASTM C1314 LOCATION 8"UPS/Battery room east and west walk(12'to top),except beam pockets;air lock walk(4'to top). MORTAR: PSI/TYPE 1800/S GROUT: PSI N/A SAND AGG. SIZE CEMENT CEMENT LIME ADDITIVE OTHER SLUMP TEMP. TEMP. SOURCE/I.D. Willamette Graystone(bagged) SOURCE/I.D. TICKET NO. SPECIMEN SPECIMEN SPECIMEN NET CROSS- COMPRESSIVE AVERAGE TEST AGE HEIGHT LENGTH WIDTH SECTIONAL TOTAL STRENGTH STRENGTH DATE (DAYS) (IN.) (IN.) (IN.) AREA(IN.2) LOAD(LBS) (PSI) (PSI) 06-03-14 7 16.00 7.625 7.625 37.95 96720 2550 06-24-14 28 15.875 7.625 7.625 38.75 100535 2590 06-24-14 28 15.875 7.625 7.625 37.95 99360 2620 2605 Reviewed By'//n{�,/cam/,f— Michael L. Meye Technical Manager • c: 0&S Contractors–Arlo Ward(email) Jacobs Engineering–Curt LaCount(email) City of Springfield(email) • MLM:vs This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such,information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing&Inspection,Inc.'s written authorization. 750 NW Cornell Avenue•Corvallis,Ora3on 97330 prone(541)7574698 fax(541)7572991 29540 B Airport Road•Eugene,Dec33197402•phone(541)684.3849•fax(541)684-3851 62979 NE Plateau Drive,Suite 3 Bend,Oregon 97701 •phone(541)382-4844•fax(541)382 4846 •