Loading...
HomeMy WebLinkAboutBuilding Miscellaneous 2014-4-28 Cor • OLSON (ST Ciwi �P7 MIOIRIRI S April 28,2014 1 D1 '7 - 0 0-1/42.0 A division of TO WHOM IT MAY CONCERN: /Pa L.B.Olson 8 Associates,Inc, Consulting Engineers This is to certify that our office staked control for construction, based on building Land Surveyors site plans,on March 25,2014,and following foundation construction,revisited Urban Planners the site on April 11,2014 to verify the build was as staked for the following Lots in THURSTON PLACE Subdivision: Lot 1 5211 Highbanks Rd. Lot 2 5233 Highbanks Rd. 380 0 Street Also,this is to certify that our office staked control for construction, based on Suite 200 building site plans,on April 11, 2014,and following foundation construction, Springfield,Oregon 97477 (541)302-9790 revisited the site on April 25,2014 to verify the build was as staked for the Fax:(541)485-3253 following Lot in THURSTON PLACE Subdivision: olsonandmorris.com Lot 4 5255 Highbanks Rd. If there are any questions or you need additional information, please feel free to contact me at your convenience. Yours truly, • i r ry s Profes i nal Land Surveyor REGISTERED PROFESSIONAL i ND SURVEYO: �. . a_ _s OREGON JULY 10, 1964 LAWRENCE 6, OLSON 655 RENEWAL DATE: 12-31-2014 • rA) SPRINGFIELD (ter * 1 .CITS F SPRINGF.IEED OREGON c 4? ` `� t+ v". '�• DEVELOPMENT SERVICES DEPARTMENT (,���,l, • " ` vyr:y4- "A. -p:' - 225 FIFTH STREET SPRINGFIELD, OR 97477 PHONE (541)726-3753 FAX (541)726-3689 www.ci.springfield.or.us HIGH-EFFICIENCY LIGHTING SYSTEMS OREGON RESIDENTIAL SPECIALTY CODE (ORSC) Permit No.: e".9 IL 2013. O `-I 2-D Jurisdiction S j2/2IN6 Flit 5 Site Address: Sgt l 141414 071.'4i Subdivision/Lot: &Acc Lo r'" l and/or Map and Tax Lot: By my signature below, I certify that a minimum of❑ fifty(50)percent, *❑ seventy-five (75)percent, of - the permanently installed lighting fixtures in the above mentioned building have been installed with compact• or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code N1107.2)1 * Check the 75%box if the additional measure selected to comply with ORSC N1101.1 and Table N1101.1(2) requires 75% of lighting fixtures to have energy efficient lamps. Signed: {[k- 1 ' Date: G/7- /l'� o nner/General Contractor/Authorized Agent Print Name: S0fr Qq', Contractor's CCB # CoO591 Expiration Date: 20IS 1 ORSC Section N1107.2. High-Efficiency Lighting Systems. A minimum of fifty(50)percent of the permanently installed lighting fixtures, seventy-five(75%)percent, if the selected additional energy code measures in the Table N1101.1(2)requires greater lighting efficiency, shall be installed with compact or linear fluorescent or a lighting source that has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this requirement. The Building official shall be notified in writing at the final inspection that a minimum of the required percentage of the permanently installed lighting fixtures are compact or linear fluorescent, or a minimum efficacy of 40 lumens per input watt. CAI-Ugh-Efficiency Inter.doc ElSPRINGFIELD I —a EUGENE;i s, COUNTY7 e� OsEGO Exterior Wall Envelope Self-Certification Form 1, 7A'A ( pa t✓c .t rJ S £'t�icC, , am the general contractor or the owner-builder at the following address: 5“- 57 Street Address 5pc-LD - City S M- 7-o 15 re) LD SZ t i b "+ 3/1-^'k s R A Permit# To conform to the 2011 Oregon Residential Specialty Code (ORSC), Section R703.1.1, I am notifying the building official that I am aware of the exterior wall envelope requirements of R703.1.1, and hereby certify that the components of the exterior wall envelope have been installed in accordance with the code requirements. [Section R703.1.1 is provided for reference on the reverse side of this form.] S co DA.vu, - Print Name L.k.tk-- Signature I tic ( �y Date Revised:2/8/201V . . SPRINGFIELD 1-• 1T PESPRINef fEED OREGON° &t S DEVELOPMENT SERVICES DEPARTMENTEtta_ Ntl 225 FIFTH STREET SPRINGFIELD, OR 97477 (541) 726-3753 Moisture Content Acknowledgement Form I, PA„+1 Cot s —ter^-- , am the general contractor or the owner-builder at the following address: SC ( I FP/cif g4Atci 21. Street Address City )fin-- Zo13 — to 141--D Permit# If applicable: 'j-1 l.,A YNL - (7'he Subdivision/Lot and/or Map and Tax Lot To conform with the 2011 Oregon Residential Specialty Code (ORSC), Section R318.2, I am notifying the building official that I am aware of the moisture content requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference.] Section P318.2 Moisture content Prior to issuance of the insulation/vapor bather approval required by R109.1.5.2 of this code: (A)All moisture-sensitive.wood framing members used in construction shall have a moisture content of not more than 19 percent of the weight of dry wood framing members. (B)The general contractor or the owner who\was issued the structural permit shall notify the building official on a division approved form that the contractor or the owner who was issued the structural permit is aware of and has taken steps to meet the requirement in paragraph(A). Print Name: 5( 0Fr 9A°) Signature i ' — Date G/ZS/IY T:\Building forms