HomeMy WebLinkAboutBuilding Miscellaneous 2014-6-9 s_i y- 0 ) 132-)
PO Box 92126-Eugene-OR 97404
• �rCommercial,Industrial,Residential,Maintenance,Control and Data
et.scrim in_,Plaone:(541)359-1192 Fax:(591)961-0507 CCB#149509
To: City of Springfield,
Electrical inspector—Guy Dixon
From: Rich Salahor,
Owner, Supervisor—RS Electric LLC
Project Address: 423 D Street
Electrical Load Calculation for : A 2 Story Dwelling with the 1st Fir @ 1300 Sq Ft & 2nd Fir @ 1300 Sq Ft
General Load:
2600 Sq Ft x 3VA 7800 VA
2 Appliance 3000 VA
Laundry 1500 VA
Range 12000 VA
Water Heater 4500 VA
Dishwasher 1500 VA
Dryer 5000 VA
Microwave 1200 VA
36500 VA
Demand Factor:
36,500 VA= 1st 10, 00 VA @100% 10,000 VA
Remaining 26,500 VA @ 40% 10,600 VA
20,600 VA
Heating:
18,500 VA @ 40% 7,400 VA
28,000 VA
Calculated Load for Service Size:
28,000 VA/240V= 116 Amps
If you have any questions or concerns, please feel free to contact me.
Sincerely,
Rich Sa lahor
RS Electric LLC
(W)541-359-1192
(C) 541-228-0200
(F) 541-461-0507