RFI 13 I�, �7 ihm r
10010 - Mohawk & Olympic Q� 71 —
EIFS - Clarification V 9� 2e73-ozq
Assigned By: david brookhart
•
• Assigned To: Scott Wallenhorst
RFI Number: 13
Date Due: 12/26/2013
Status: Completed
Category: In Process
• Request: SUBJECT: EIFS Details
SPEC/DRAWINGS/DETAIL: 39A-39C/A7.2 Location: Varies
QUESTION: Confirming the depth of the reveals is 1"?
Response: The width of reveal is 1"and the depth is W. This is the only size.
•
Attachments,
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
Page: 1 of 1 1/2/2014
•
Task
RFI 14
10010 - Mohawk & Olympic
Electrical - Clarification
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 14
Date Due: 12/24/2013
Status: Completed
Category: In Process
Request: Sheet E3.1, shows the"service grounding detail'. Is there a specific
location or area that the "grid should be installed in? Contractor has
suggested placing ground rods under the building slab.
Please advise.
Response: Please find the Electrical Engineers response below:<br><br>TBA
Recommends installing the ground rods outside of the building
footprint.<br><br>Jeff Salvagin-TBA
Attachments
There are no attachments for this section.
•
Document Links (Existing documents within Expesite)
There are no attachments for this section.
Page: 1 of 1 1/6/2014
•
Task
RFI 15
10010 - Mohawk & Olympic
•
Concrete - Clarification
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 15
Date Due: 12/23/2013
Status: Completed
Category: In Process
Request: On sheet S1.0, grid line 4 between A&C, dimension string for 12'-6"
sheerwall.
At the north end of the dimension string, there is an additional 3" call
out that appears to conflict with the note"from A to end of stud wall"
located below dimension string. Please confirm distance from A line to
end of sheerwall
Response: Please find the Structural Engineers response below:<br><br>The
12'-6" dimension is from face of stud to face of stud, therefore the
dimension from grid A to end of stud is
12'-9".<br><br>Thanks,<br><br>Patty Fellenstein -TBA<br> •
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite)
•
There are no attachments for this section.
Page: 1 of 1 1/6/2014
Task
RFI 16
10010 - Mohawk & Olympic
Glazing - Clarification
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 16
Date Due: 12/26/2013
Status: Completed
Category: In Process
Request: Please confirm if the alternate for the Storefront is going to be selected
or the base bid.
Response: After discussions with KeyBank the base bid has been selected, this is
the 1600 Series Curtain Wall system 3 with inside glazing option.
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
•
J
Page: 1 of 1 1/6/2014
Task
RFI 17
10010 - Mohawk & Olympic
HVAC - Clarification
•
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 17
Date Due: 12/26/2013
Status: Completed
Category: In Process
Request: Please confirm is the alternate for the Mechanical system is going to
be selected or the base bid.
Response: Per KeyBank the Alternate HVAC drawing has been selected.
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
•
Page: 1 of 1 1/6/2014
so
Task
RFI 18
•
10010 - Mohawk & Olympic
Site Utilities - Clarification
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 18
Date Due: 12/26/2013
•
Status: Completed
Category: In Process
Request: Sheet C5.0, sanitary sewer note 2 states the assumed I.E. to be
457.65. Actual IE of existing SS connection is 463.38.
Per sheet M1.1, the SS exiting the building should have a IE of
462.80. This is .58' lower than the existing P.O.C.
Please advise
Response: Please see the Mechanical Engineers Response below:<br><br>Set
the inv. at the exterior wall at 463.59'this will allow the sanitary to start
• at 2' below finished and meet the invert of the sanitary on
site.<br><br>Site San Inv.=463.28'<br>F.F. elev.= 465.80'<br>20'
pipe at 74"/FT slope= 0.21' 564.80'- 0.21'=456.59'<br>465.59'-2.0'
(start of san below floor) =463.59"<br><br>Thanks,<br>Mark
Neuendorf-TBA
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
•
•
Page: 1 of 1 12/20/2013
•
Task
RFI 19
10010 - Mohawk & Olympic
Concrete - Request Alternate
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 19
Date Due: 1/3/2014
Status: Completed
Category: In Process
Request: On sheet S1.0, near grid line 8, between B & C lines, The hook bars
• as shown in detail 1 on S2.0 for the curbs at the short walls of the ATM
bump out were missed during the initial footing pour. We would like to
propose installing the hook bars (4 in total) at this location with
"Simpson set-xp" adhesive before the slab and curb are poured. If this
method is acceptable, please confirm required embedment depth
Response: As we discussed on Friday, below is the response from the Structural
Engineer.<br><br>This method is acceptable. Please provide 6"
minimum embedment into the footing pour.<br><br>Thank
You,<br>Patty Fellenstein -TBA
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
•
Page: 1 of 1 1/6/2014
Task •
•
RFI 20
• 10010 - Mohawk & Olympic
Structural Metals - Detail Required
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 20
Date Due: 1/13/2014
Status: Completed
Category: In Process
Request: SUBJECT: Jamb Stud/Track Attachment
SPEC/DRAWINGS/DETAIL: 9/S0.6, 1/S2.0, S0.1 Location:
Varies
QUESTION: The lower portion of detail 9/S0.6 shows the jamb stud
attachment to the bottom track using a 1.5" x 1.5" x 54 mil clip, with
the angle clip attached to the concrete using (2) .157 PAF @ 4" o.c.
Detail 1/S2.0 shows that the concrete curbs are 6"wide. The PAF note
on S0.3 tells us that the minimum edge distance for concrete is 3".
At all locations of door and window openings the adjacent framing is
built up on concrete curbs. Please indicate how to achieve attachment
of angle clip described in 9/S0.6.
Response: Please see the Structural Engineers Response below.<br><br>FOR
THIS APPLICATION ONLY, the clip may be attached to the curb with
the specified PAFs spaced at 2" o.c.<br><br>Thanks,<br><br>Patty
Fellenstein-TBA<br>
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite) ,
There are no attachments for this section.
Page: 1 of 1 1/14/2014
•
OUTLINE OF DRIVE
TNRU CANOPY BY
CANOPY VENDOR
it. 9 9
(53.2) 53.2
B
Wri
OPP
BUILT-UP • 71.4,11 MAX SPAN
NEADER PER I
DETAIL 4/50.6
I. I 411
I I I I
I I 11 I N
II I II
I 2505137-43 0
L I I/2' X I I/2' X 43 MIL X 0'-2 I/21 LONG CLIP I 10 O.C.
WI (2) 4110 SCREWS IN EA. LEG, TYP. EA. CORNER I - 2505137-43 JAMB
STUD EA. SIDE OF
_ SI� I OPENING
I , TYP.
I
OUTLINE OF I I z
WALL FINISH— �I =I 'zit
•
i-'`I
I 2507150-43 @
' TOP 4 BOT. OF
2-0 MAX -/ .2-0 MAX f I I OPENING, TYP.
I I I
I d_J< c _y at _ .� 4 1
` ' : :•, .
`PAVING PER CIVIL TRACK PER DET, 5/52.1
`FOUNDATION PER 521 FOUNDATION J
PLAN MD DETAIL BEYOND
PARTIAL ELEVATION
0 •
AT ATM/AND OPENING
SCALE N.7S.
REVISION ISSUE:Q REVISION TO SHEET'.
113
ISSUE DATE: 01.07 2014 PROJECT NO. 2013-0367
KEYBANK S3.2
SKETCH NUMBER.
Thorson Baker Associates 1625 Mohawk Boulevard
C O N S U L T I N G E N G I N E E R S Springfield,OR 97477 S K-S-R F121 -1
3030 West Streetsboro Road (330)659-6688 Ph.
Richfield,Ohio 44286 (330)659-6675 Fax VOCON
•
I- ill
SEE I/53.0 FOR ADDITIONAL INFORMATION
I
BUILT-UP METAL STUD HEADER PER PLAN 4 DET. 9/S0.6 II
ROOF SHEATHING PER PLAN _
r
II is
I lie (3) ROWS OF #10
VSCREWS @ 16' O.C.
T/STUD= 9'-6' MAX
r
I •074Pntele
ai I \
JOIST PER PLAN WITH
0 w FINISH PER ARCH I I CONT. 600TI50-43 EA. END CONT 600TI50-43
? l WITH #10 SCREW EA. SIDE FASTEN TO EA JOIST WITH
d 0 #10 SCREWS EA SIDE
(3) #10 SCREWS AT EA STUD
= z
r BUILT-UP METAL STUD HEADER
PER PLAN 4 DET. 9/50.6
a
250T150-43 CONT. FASTEN TO
EA. STUD W/ #10 SCREW EA. SIDE
FASTEN TO HEADER ABOVE W/
\ Il #10 SCREWS @ 5' 0.C.
TRACK TOP 4 BOT. OF OPENING
STUD WALL PER DET. 5/53.2 PER DET. 5/53.2. FASTEN TO
EA. STUD W/ #10 SCREW EA. SIDE
(El) WALL SECTION AT ATM
SCALE: N.T.S.
REVISION ISSUE:A REVISION 10 SHEET:
13 ISSUE DATE' 01.07.2014 PROJECT NO' 2013-0367
KEYBANK S3.2
SKETCH NUMBER:
Thorson Baker Associates 1625 Mohawk Boulevard
C O N S U L T I N G E N G I N E E R S Springfield,OR 97477 S K-S-R F121 -2
3030 West Streelsboro Road (330)659-6688 Ph.
Richfield,Ohio 44286 (330)659-6675 Fax V000N
•
•
Task
RFI 21
10010 - Mohawk & Olympic
Structural Metals - Clarification
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 21
Date Due: 1/14/2014
Status: Completed
•
Category: In Process
Request: SUBJECT: ATM Framing Clarification
SPEC /DRAWINGS/DETAIL: 5/S3.2, 9/S3.2, 6/A6.1 Location:
8.2/B.5 Line
QUESTION: 1)The right side of detail 5/S3.2 shows a maximum
distance to the bottom of the box beam header as 6'-7"AFF while
•
6/A6.1 shows the same location with an elevation of 7'-0"AFF.
Confirming the former dimension of 6'-7" on 5/S3.2 is the correct
•
dimension.
2) The lower portion of detail 9/S3.2 shows the face of framing aligning
between the transition from 6"to 2 ''/z' framing. 6/A6.1 shows that the
6" and 2 '/z"framing is offset at this same location.
Confirming that 9/S3.2 is the correct profile.
Response: The 6'-7"to bottom of beam header is the minimum dimension allowed
for ATM clearance. This dimension is acceptable.<br><br>See revised
structural detail #5 	 on S3.2 (SK-1 and SK-2). Follow the
structural revised drawing showing 6" & 2 %" stud aligned. There is no
parapet for the ATM roof. The roof framing is 9'-6"from finished floor
to top of metal joist. See architectural section#6/A6.1 and detail •
#31/A7.1.<br>
Attachments
2013-0367_SK-S-RFI21-1.pdf - 38 Kb
2013-0367_SK-S-RFI21-2.pdf 39 Kb
•
Document Links (Existing documents within Expesite)
Page: 1 of 2 1/14/2014
Task
There are no attachments for this section.
•
Page: 2 oft 1/14/2014
Task
RFI 22
10010 - Mohawk & Olympic
Structural Metals - Clarification
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 22
Date Due: 1/14/2014
Status: Completed
Category: In Process
•
Request: SUBJECT: Header, Jamb and Sill Schedule
SPEC/DRAWINGS /DETAIL: S0.6
QUESTION: The Header, Jamb and Sill Schedule, Key: H-1 describes
a jamb stud built with (2) track and (2) studs and refers to Det J-2. J-2
shows a configuration with (1) track and (2) studs.
Please clarify which is correct.
•
Response: Please see the response below from the Structural
Engineer.<br><br>The header construction shown in the schedule is
correct. The H-1 header in the schedule should reference detail J-4
.<br><br>Thanks,<br><br>Patty Fellenstein-TBA<br>
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
Page: 1 of 1 1/14/2014
r . .
Task
RFI 23
10010 - Mohawk & Olympic
Rough Carpentry - Clarification
•
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 23
Date Due: 1/14/2014
Status: Completed
Category: In Process
Request: SUBJECT: Room 114,North, East and West Walls
SPEC /DRAWINGS/DETAIL:A1.0 Location: 5.7/B.2
Line
QUESTION: Room 114, north, east and west walls aren't labeled with
a wall tag. Sheet Note 5 says"All partitions Wall Type 6 UON"
Confirming the walls described are Wall Type 6.
Response: Use wall Type 5 for this area.
Attachments
•
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
•
Page: 1 of 1 1/14/2014
.
•
Task
•
RFI 24
10010 - Mohawk & Olympic
Rough Carpentry - Clarification
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 24
Date Due: 1/14/2014 •
Status: Completed
Category: In Process
Request: SUBJECT: A7.1 Clarification
SPEC/DRAWINGS/DETAIL: 16,19,23/A7.1
QUESTION: Each of the above details has a note regarding the 3 5/8"
metal studs saying to"See structural drawings". The structural
drawings don't reference these studs.
Please clarify.
Response: Studs to be 18 Gauge
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
Page: 1 of 1 1/14/2014
. .
Task
RFI 25
10010 - Mohawk & Olympic
Rough Carpentry - Clarification -
Assigned By: david brookhart
• Assigned To: Scott Wallenhorst
RFI Number: 25
Date Due: 1/14/2014
Status: Completed
Category: In Process
• Request: SUBJECT: Room 101, West
SPEC / DRAWINGS / DETAIL: 4/A8.0 Location: 2/C-F
Line
QUESTION: The head of the storefront system in 4/A8.0 refers to
2/A7.0.
Confirming that the correct detail is 2/A7.1.
Response: This should read a 22/A7.1 just as it does on Section 5 on A6.1.
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
Page: 1 of 1 1/14/2014
•
Task
RFI 26
10010 - Mohawk & Olympic
Structural Metals - Request Alternate
Assigned By: david brookhart
Assigned To: Scott Wallenhorst
RFI Number: 26
Date Due: 1/14/2014
Status: Completed
Category: In Process •
Request: SUBJECT: Roof Framing Detail
SPEC /DRAWINGS/DETAIL: 5/S3.0 Location: Varies
QUESTION: 5/S3.0 shows Simpson S/HJCT joist hangers welded to
• the beams.
In lieu of welding is it acceptable to use (2) PAF's for attachment to
beam flange?
Response: Please see the Structural Engineers Response below:<br><br>The
Simpson S/HJCT hangers may be attached to the WF beam by using
self drilling screws or welds as shown in the Simpson catalogue.
Alternate fastening options, such as PAFs, must be reviewed by
Simpson for acceptability and recommendations.
<br><br>Thanks,<br><br>Patty Fellenstein -TBA<br>
Attachments
There are no attachments for this section.
Document Links (Existing documents within Expesite)
There are no attachments for this section.
Page: 1 of 1 1/14/2014
Lai
I'' - -n win–tit t iSit Siola
PITCH EIFS /
MEMBRANE. I \ // PITCH EIFS PARAPET
ELIMINATE STOP I : __ _ Y.
FLASHING. t—\
ROOFING MEMBRANE i
3"OUICKSEAM SPLICE TAPE — i I I I — - '-- —
OUICKPRIMEPLUST ..I "` 1 ,1, H,, !
r-----/____\,— 11 E— __ ,, ._I—r—I
ye \I-1 I _
SEAL BETWEEN I �� 1
EIFS EDGE & iI -' I ._ __.
MEMBRANE I I II
EXTEND EPDM j I / ) i • I_
_._
UNDER N. & I I ( -I
LAP DOWN. \
/ I
--\ I •
4"PLYWDSHTG / ! � I� I- ~—�
� / I
\� I i_ _ I_II� —
I I
K_/ i 11 !___I i
•
E14� DETAIL
/ SCALE: 3"= 1'-0"