DAILY FIELD OBSERVATION REPORT
Page 1 of 2
Client: E.A. White Construction Company, LLC Permit No.: City of Springfield: 811- Date: February 13, 2014
SPR2013-01715
Project: Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-40
Springfield, Oregon 97477
General Contractor: E.A. White Construction
Subcontractor: W.W. Construction Weather: Cloudy, Rain
Company, LLC
Location or Items Observed: Soils Observations (Tax Lot 100) • New Observation ❑Re-Observation
Type of Observations
❑At Completion • In Progress ❑ Post Completion ❑ Continuous o Periodic ❑Other
Arrived: 8:30am Detailed Observation Notes Departed: 10:00am
As requested by W.W. Construction, Inc., Earth Engineers, Inc. (EEI) representative Ray Aliperti was on-site today to
observe exposed parking lot and driveway pavement subgrade soils within Tax Lot 100 (see attached site plan). Prior to
our arrival the area had been excavated to finished subgrade elevation using a John Deere 160C LC excavator with a 4'
wide smooth bladed bucket. According to W.W. Construction representatives the area was excavated to allow for 12" of
crushed rock and 3" of asphaltic concrete. The exposed soils appeared to be similar fill soils as described during our site
visit on January 27, 2014 (reference our report 13-029-37). Due to the rain making the surface of the subgrade very slick,
the subgrade could not be proofrolled. Therefore, to assist us in determining the stability of the exposed soils we used a
geotechnical soil probe. Based on soil probe penetrations of less than 6", the subgrade was relatively firm and stable at
this time with the exception of the following area: an area measuring approximately 12' by 15' near the southeast corner
(see attached site plan and photos #1 and #2 below). At this location the uper 3' of subgrade contained an abundance of
pvc pipe. The area was overexcavated to remove the pipe and then the excavated material replaced with additional
crushed rock.
To the best of our knowledge, the work observed on this date was in accordance with our previously submitted
geotechnical report entitled " Geotechnical Investigation Report, Proposed Candlewood Suites Hotel, 3005 Franklin
Boulevard, Tax-Lots 100 and 700, Springfield, Oregon, EEI Project No. 13-029-1" dated April 2, 2013; as well as our
report 13-029-37 dated January 27, 2014.
•
•
-
EEI Report No. 13-029-40
February 13, 2014
Page 2 of 2
;;.. Wes Y I rd7..�P` tt ff•
ry,� « 1' �., asd_ ` * '� _i , ate .,
U7 + iµ1 °+µ� "� 7 ,e���F, + ..Nn � M' h R4 S. {` § s,;li F 4a i 'd w k i
`A�'vtkv'a 1.I . ' 5,•4a'Ms - .. � u-' < .'F1S .* ra' 9a# t a» '! B s pze
xt -. Oro+ \ C .r1 v .. t F 1'}t,fro.'i d4`� + r 'ffi`¢ r$ y KS 'r u�a nyF-°*.
```^ 'x _.'i`2C" .0 bi74 f4..'i: i `rit'aeluJ. i, `t 0•i'4E•x ,6 a t', :y Steed �'R} {t' + �'t� P. �!+rp�TT• � !t i s
• '*', "3 :Jt r 4 v1 w}+ e',A rit : 4 d v44 2 s. ;:t4 'w'y .J,p '.;;
l't . S xt` mr.s..:..;. .,t++r v .4 k„'7"1 a H & tt.:+. N
pc,
{ �Y i L. P.''e ,y ,�Yyi'` , '.•l`1. rg ',If ��G, j- v„...4 7xs sV 0
0. I •Ras+H ..,r it "t r, i { •'; yt«•At -'1'
fe i�a°i (. . . i . _ t v
■ ry i [ tr ,�L(tl.5. i Klitt •Y [5, +i "'CI. i , . AV 4 } +:M1 t, �.A',LIN
l ,- 1 it rt. .1�.� 1 .,'T ivy K`i.
ff'' �Y.C•r "',. r i ii- CS jar s • r"-} f i a @ ar tiG9f ' k WV'.:..,4•h j X' Ma t•i +"7' ' 1 _ " y�g na. S.xiif�}x� Du "L+t.~ r; "�.r �•c+F\ 1 "'Ab f' ' P..+' 'tt 'dr....G,Y ''' !' c,+:L r b i`t.� ,,. •% K : x. !,� . r.-
Photo#1: PVC pipe the earthwork contractor Photo#2. Another photo of the PVC pipe the
encountered in the parking lot and driveway pavement contractor encountered in the parking lot and
subgrade of Tax Lot 100. driveway pavement subgrade of Tax Lot 100.
•
•
Attachment: February 13, 2014 Site Plan
Distribution (electronic distribution only):
Pete White— E.A. White Construction Company—petew(a�eawhiteconstruction.com
Al Patel —Candlewood Suites Hotel—alpatel9(Thgmail.com
Andrew Bremmeyer—Wedgewood Services Inc.—andyb(&wedgwoodservices.corn
Ryan Hardie—All Structures—rvanh(aallstructure.com
Todd Singleton—City of Springfield—tsingletonW springfield-or.gov
Robert Castile—City of Springfield—rcastile(o)springfield-or.gov
Field Staff Name(Print): Ray Aliperti Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: ) Copy of Handwritten Report Left on Site: No
•
r
Our observations do not relieve the contractor from performing in accordance with their contract and approved permit documents.
. ` ' - _- -_� - -__ __-' �-'-- _ eiii
' �
L.
co
\ •-•/8I1 1 5:0,7 r
fi 21
,,\
eri
" ••\
1.--65 --, g \ :CI
•4 ;;;;517,11tc
\ Irt,rk../J-3,....21---:::--iLair—t---"r-'a r-------;r7;>rni—art.rrtf17://77.414m71" \‘'''''-'2>znaw ;:calrTsw I
i , 0 R,A,u; ,..., 2 \\,., ,4,,,
ik_i ''-: d '', .' "-1•••,- -•••Ii. -n '..i
1 i' •C i Eil . - to ---• -_\) 4.4_,0 \;;;(5 r
1 ;:.i.,4 ,r?e :::.,_, cs it,.
. .
W r1/4)
.
Earth
t! 88948 Bridge Street
•• Engineers, Springfield, Oregon 97478
(P) 541.525.6759
Inc.
DAILY FIELD OBSERVATION REPORT •
Page 1 of 4
client: E.A. White Construction Company, LLC Permit No.: City of Springfield: 811- Date: February 14, 2014
SPR2013-01715
Project: Candlewood Suites Hotel Address: 3005 Franklin Boulevard, ED Report No.: 13-029-41
Springfield, Oregon 97477
General Contractor.E.A. White Construction Subcontractor: W.W. Construction Weather Cloudy, Rain
Company, LLC
Location or Items Observed: Soils Observations (Tax Lot 100) • New Observation 0 Re-Observation
Type of Observations
C At Completion • In Progress 0 Post Completion C Continuous • Periodic 0 Other
AM: Arrived 9:00am, Departed 10:30am Detailed Observation Notes PM:Arrived 3:00pm, Departed 4:00pm
AM: As requested by W.W. Construction, Inc., Earth Engineers, Inc. (EEI) representative Ray Aliperti was on-site today to
observe exposed parking lot and driveway pavement subgrade soils within Tax Lot 100 (see attached site plan). Prior to
our arrival the area had been excavated to finished subgrade elevation using a John Deere 160C LC excavator with a 4'
wide smooth bladed bucket. According to W.W. Construction representatives the area was excavated to allow for 12" of
crushed rock and 3" of asphaltic concrete. The exposed soils appeared to be similar fill soils as described during our site
visit on January 27, 2014 (reference our report 13-029-37). Due to the rain making the surface of the subgrade very slick,
the subgrade could not be proofrolled. Therefore, to assist us in determining the stability of the exposed soils we used a
geotechnical soil probe. Based on soil probe penetrations of less than 4" (see photo #3 below), the subgrade was
relatively firm and stable at this time.
PM: Returned in the afternoon to observe the remaining exposed subgrade soils for the parking lot and driveway
pavement subgrade soils within Tax Lot 100 (see attached site plan). Based on our soil probe penetrations of less than 4"
to 6" using moderate pressure, the subgrade was relatively firm and stable at this time:
After our subgrade observations in the morning and afternoon, the earthwork contractor immediately covered the areas
with geotextile fabric and imported 3/4"-0 crushed rock from Delta Sand and Gravel. At this time the parking lot and
pavement subgrade areas within Tax Lot 100 are complete. Informed by earthwork contractor that at this time they will
place the 12" of crushed rock and compact it so that the area can be used as temporary parking and storage. At a later
date the rock will be re-graded, compacted, and tested for compactive efforts prior to placement of asphaltic concrete.
To the best of our knowledge, the work observed on this date was in accordance with our previously submitted
geotechnical report entitled " Geotechnical Investigation Report, Proposed Candlewood Suites Hotel, 3005 Franklin
Boulevard, Tax-Lots 100 and 700, Springfield. Oregon, EEI Project No. 13-029-1" dated April 2, 2013; as well as our
report 13-029-37 dated January 27, 2014.
EEI Report No. 13-029-41
February 14, 2014
Page 2 of 4
\�a F 1 141 It Y i
p
9 + }3 i
f' 1 L .� i Y. Iii I :*1\4. ,••i;
` Ltt
ddd b , 4 ¶j ib ,� 1,w u x f- 71 a . _ ,..1, h.
K '-: � '`Lfit '` t -.,ate 2
�ti °
„ �.s+,..4;;;,.;y,r„,...u,°L�a4 e�. = as "r "C-: ;'r vthle
r,, 5 W � .02,---....-1✓s-' r•t-_ "ice" r� 1 -.t- :
f . T i.M } 3 �L't/a�r4 2w kt,
W
w
'E Ya{"' lett .vn '! dpi pavement subgrade
within Tax Lot 100 observed during our morning site visit.
•
,
�='r d
1� /
•
OP4 YLh 'l
��• ' .i rl I ii (J
r3. ( t? .t_ i t `-h- F (may_`
t =.tip t Y¢ ftt
kt 1 1r i1 .a R& Y - r
1'911.11 .. ��"11�1 A,.., ,%-.4. �, y}, .^'PY
�' '�}+i'$'sry t «"'i�� i7i-�.L��t�ks. 2, '*�` _WeetegGlIte
�y L v r yin ;
SEittfltril
*r lam 1 < a . F.:Ga�` E' ' .ya'02(„I4!.�.O dL4�f ..1 „J1�/ . " f`Yl t 1{w* arSL�A+W�Y '�Y w
Photo #2: Stockpile of excavated mater ial from area obse rved d uring our
•
morning site visit.
EEI Report . 232900-4
February 1 , 14
Page 13-04 f 4 1
t
tl k
15.`iIY�y4N�yy. C JS _M.SN ;.1 14 h 1 # +
"�{ ,y'c to i 4+ r .r� °" a t- :, �� swat. i
* c� '} L'3 ,a ri 4,:,"1. I1I�.�` n � .r-c "'k� N .w' ra.
•4ia +mow' y1'r -a::4 ^ 6 t a E ms+., 4;:*.:tVr,..
.kv"� r? + � .t'G 4 49i m q�pw . liklt d :: "7. .. ,... 7:4‘7,..t7 '`•Z.N`,{z..mr. y,,i !n!- .,'�.,i�i . ,rz C ^t,..44.04:::-.4,-
4... 5.J.^b" , 4 lU v:. ,ir. £
t"' ��,,!! .s ms's .. edaY.
r toy :174M M 4 �'w 4114 f i i i-ry � `na i Y r 4e k
.emu ti, tyd'it M e' � a Vi0. .,f" yi.'.Y 61*Ert 'it' a-. . L"vat), C.
,#)--,4:4-ta `-!�t 'n 4 ty.�95 lY?' k n r r�� r,YL r. . ;;W"r�
a
r�. i4 f , +:/ 'yr 'YwY ,i cak '� rrr4+',. ! +y ,
�,S�Ate�-+ �, i x --Alt 7; ?#'a ..+. J u'V.: ."' 1vt-E '4i/2 9 4,!Sr*
e a tCPlFtr,F. 'S.'' i \.nr+o.1.-t..... . ,.,� . xi'.^•.
Photo #3: Exposed subgrade soils during our morning site visit. Using
moderate pressure the soil probe only penetrated the subgrade about 3" to
4".
1 .' . 5 +w ire .�
rr is ` n?f ;
II t�� '
y 5. h fy
a 41 {q5' b ^y�
✓1/y�y_`va` y}p1 1"� '�tif4$1'�S4{7 / / '1-
IC-c,44 10"%i 1„-„..„sq.„,,,+ x y 1`,, �'di �'1 .S.f r'(r t'�.iiii.rim 7 ,,.
0
y
, �j,, �n 4 I L^in
. i? '” jYn r� m San * , . 1,a0 d/14/x till
r$4 ,v: dr kp $fir ,, #a•��:i i• �R +.
Photo #4:...r Portion of the area that was observe d this morning is now
covered with geotextile fabric and uncompacted crushed rock. Beyond the
excavator is the area of exposed subgrade soils observed during our
afternoon site visit.
EEI Report No. 13-029-41
February 14, 2014
Page 4 of 4
rah?. a .z."�---q°�rt;i190 ,I f N1",r'C. t 1 r rp rr s is
. J•,i��y—as.4,: 'TT: .0.' ' frc nlyt, '' 'Z7a7 ryr¢ su. �:
'7ti ct ,v Y ,yam+
e�+�-r' W �S �1,�t':-',�,"k$r.,c +'{n. .o+%�.�S.r. {x � #+t.Y-r*-.;� w4`� `
ri t°•as4%tr :.s:bz..'r 4`.k ty'b "e„ !Pr`'{.✓2.`+1,'.51+itSCej.1
NYr,. •414•a"4 r :J.Y�v" =v.-. ,� ,�i_:3n4-▪ 4 4,:':y. Krski'kc,.. T
K "',.L�l r '^� 43#kie-41:t p�`w x". I �w: -A� ao'4-
g47 f c,; '"`'�`°.�a 'a;"�t'la�ra ;T:ia•7M f,'..i".w+."fhf it:
Q N p"an+.w i'�- s ki• W1....-4,'"*. x,1.'4" +Y 3fl., ra,try t•Y 1 ,.•
e•i lS � ,a ,7 At:a+ 1 pA.. tie'✓..,%,,
,- :..4.1 Z""3j•.
4Y x4i tv 0 n or✓' , W t 1 4� x ClJ,,.£
• ttV tt 4A G'd'1' i +i A ..ifr'�jwCay,a-'n '+� Gr 'T `9s
0e9gQ o .
,14--,^;rr F :7' 7 �' A• r• av t v1/4;`):=1/41/4"!-A1):1/41/4'
�n y t- St t,':• "g 4;i t,:t aLfst*,.f.'..
Photo #5: Exposed subgrade soils during our afternoon site visit that was
overexcavated approximately 6" to removed pieces of rubber, plastic, and
asphaltic concrete.
1
� t 7,
YVA1. fi i ,
r••
or HZ.A I II
QTR'11 [ J
y l *k 1 f V
F , }f '3
r57L'i y �'}Il q aT' E.5 T.i Y 1 4, M. ( ,-,i.;- i.•
� y S�F A y -k. �p l
^'E'ilY -).:1f VJ Y K. rx G. ,p.l r iS.24
Et � Y,"t, -)N - X71 R 'n' �Y▪ -,-.:y• . $'...1 ;
k fi ° ,f x , Yyt c +-A r
. r- - M l< C rtrT. . y r
1 44 4141,44!4W,-. y..'l� `1.i 'ycyM' -F4 y rr 4i,e,a e
1
otevv Wy N '• - n s " .ta &04,A or•£ y - - �'i a� ' -hips � , 4a:am 11 'r t t xy« ° -tr . n . �1 ` y {� `rSt 1 « '; Y , 44;; 5 4V-k- 'ai :,
-
a).:';;:it? ;r .,=. aar.g..-fi r. 3 Aaryc074 ..1 4a *,-:..y
Photo #6: Stockpile of material to be hauled off-site that contained pieces
of rubber, plastic, and asphaltic concrete removed from exposed subgrade.
Attachment: February 14. 2014 Site Plan
Distribution(electronic distribution only):
Pete White-E.A.VVhite Construction Company-petew(Weawhiteconstruction.com
Al Patel-Candlewood Suites Hotel-alnatelgOgmail.com • Todd Singleton-City of Springfield-tsingieton(W springfield-or.gov
Andrew Bremmeyer-Wedgewood Services Inc.-andvb(Thwedgwoodservices.com
Ryan Hardie-AM Structures-rvanhno,allstructure.com Robert Castile-City of Springfield-rcastileggtspringfield-or.gov
Field Staff Name(Print): Ray Aliperti Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: Copy of Handwritten Report Left on Site: No•
Our observations do not relieve the contractor from performing in accordance with their contract and approved permit documents.
. . r .
. .
CM:s.
.c.,,/..:T...44 g li p Ili, d , 3 !Ili 9 5
, . Pr
-‘‘ ?'?:) 91 /113110.0ilii Iii 11.1 g .-E: ei •: j ,I1
<Li>le.,...t iii .II; 1
';'• ; I ‹,.. * I X-0, I 21 t Ill 1 . 1 Hi.1• 1"eJE,.,
fr,L 0 d nip fop ;, 62 rgi zE ?.;: ti :6. ir :4 ,I„11
:33 iS li ile•'" 11" - : 7: n i- “.i HUN : :-..... II < fki"
0
?Or:::■,:2 .-- -"-... *N>., c.,
,c,;,...,_,. ........■
i c., 211 at.
____..-----
i„,:,F ....„---:;.- %a
4:: r,------ . 1 '1
<.:. i; .4,------11 ,I
0 ft
,-,-. -
Li 44,.
"Lc
\ d
12,f 1---- j1
t
t ...
I
V (Jo
usA
K,-
te.,•4Ali. , n
I I ,4
lc)Er FITE 'i I\
\
-,/1,74D'`?
= /".,-.,- /
■ :7/4/7 1..r,y;it;
ta i; ,:t; ,.;:f_t ---7,2.-2- 0 t 1 r- (
I 1
I:'' \ ./. - 1 11?.,'`-■3: /5 L 1 Cf) i--"C"))
..-4:-. Pc iS
1 \ 1 *
• .‘ Q 1 .4)
it r
:Ace
o co
e° 114 0 z g5/11 I 1 I I\ I
?,.. , ____, ,___-:- < __ ____x. ,,
,,,,. ..., . ,
.0w 3°1 1 ' z I— t
- • ,r./..e..> co -, h 1 I °,
-•
°!---,\ ``' r 1:7•0 ar. / -- ,i. —F-
r
,,,,\ ; ,.:-
J -CO R
,,, :.4 \ ,
I PI, e
\ gi \
2
.::
- i 7
3
\ \ L.___ (---q ______
, 4
, , c., .
, , _ --1 \`)
, _ A
r---,,---;---‘ ( 1 -"•ft. ,
1 #: ....allQ----095TJNP2n.Ada02.1=00310.7r" 441.01.....S.,+....a.nr.K...■„:).\ TOIstern 4
\ .
10:7/y'
- h..
se&--
\-1 I I fl I I 1 11-I ?.c..):,,,, \\ ,,,z.
; S
‘q 2 6 g Ini 7-• I
'‘C..L....) /7-1 t
I
4: -.• K
' rl K
'.0
+0 L
0:1
) gt)r 1.Petr'snZ.‘141; \
ef.nssilr'?
„, ---,,
n iii'
U g ?, riN .,.
, N t:•t',I' 0 „ -.'----..,,, -...*-4$ p= a4 •
c'.
L: ":,2. •P.''e 51"
•1,“ “'•
1
1.=.4
=
4 6
°;.,g 4, 'ut O5t-1. Z1-i.*.5N,.• :";:
---
.
z \ c_-r17\ a g/
ex=p
:t.
Ira
Or
Zri
:,••,,• ,,,,a,.. ,...,
W 0
•
L...
Earth
88948 Bridge Street
Engineers, Springfield, Oregon 97478
(P) 541.525.6759
Inc.
DAILY FIELD OBSERVATION REPORT
Page 1 of 2 .
Client: E.A. White Construction Company, LLC Permit No.: City of Springfield: 811- Date: February 11, 2014
SPR2013-01715
Project: Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-39
Springfield, Oregon 97477
General Contractor.E.A. White Construction
Subcontractor: W.W. Construction Weather: Cloudy, Rain
Company, LLC
Location or Items Observed: Soils Observations (Tax Lot 100) • New Observation 0 Re-Observation
Type of Observations
0 At Completion • In Progress 0 Post Completion 0 Continuous • Periodic 0 Other
Arrived: 2:00pm Detailed Observation Notes Departed: 3:30pm
As requested by W.W. Construction, Inc., Earth Engineers, Inc. (EEI) representative Ray Aliperti was on-site today to
observe exposed parking lot and driveway pavement subgrade soils within Tax Lot 100 (see attached site plan). Prior to
our arrival the area had been excavated to finished subgrade elevation using a John Deere 160C LC excavator with a 4'
wide smooth bladed bucket. According to W.W. Construction representatives the area was excavated to allow for 12" of
crushed rock and 3" of asphaltic concrete. The exposed soils appeared to be similar fill soils as described during our site
visit on January 27, 2014 (reference our report 13-029-37): Due to the rain making the surface of the subgrade very slick,
the subgrade could not be proofrolled. Therefore, to assist us in determining the stability of the exposed soils we used a •
geotechnical soil probe. Based on soil probe penetrations of less than 6", the subgrade was relatively firm and stable at
this time with the exception of the following area: an area measuring approximately 3' to 4' wide across the low elevation
point in the parking lot where the storm water will be drained (see attached site plan and photo #1 below). At this location
the upper 6" of subgrade was saturated and very soft. We recommended removing this material and replacing with
additional crushed rock.
After we observed the subgrade, the earthwork contractor immediately covered the subgrade soils with geotextile fabric
and began placing imported 3/4"-0 crushed rock from Delta Sand and Gravel.
To the best of our knowledge, the work observed on this date was in accordance with our previously submitted
geotechnical report entitled " Geotechnical Investigation Report, Proposed Candlewood Suites Hotel, 3005 Franklin
Boulevard, Tax-Lots 100 and 700, Springfield, Oregon, EEI Project No. 13-029-1" dated April 2, 2013; as well as our
report 13-029-37 dated January 27, 2014.
EEI Report No. 13-029-39
February 11, 2014
Page 2 of 2
•
r :. ierrl{�y r
f I,
s j
I In
r -tfir+ c Fa � 4'!f!°
n a
• J �� a l d b y < w ..x
rc 4 •
xx ` fi 02r
:1.:;"” 41'
120lIt4 r
lr'sq `< M". i q 4fit ),A i 6( rte,
Photo #1: The 3' to 4' wide area with standing water adjacent to the
geotextile fabric is the area we recommended overexcavating to remove
soft, saturated soils.
Attachment: February 11, 2014 Site Plan
Distribution (electronic distribution only):
Pete White—E.A. White Construction Company—petew@eawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9@gmail.com
Andrew Bremmeyer—Wedgewood Services Inc. —andyb @wedgwoodservices.com
Ryan Hardie—All Structures—ryanh@allstructure.com
Todd Singleton—City of Springfield—tsingleton@ springfeld-or.gov
Robert Castile—City of Springfield—rcastile(springfield-or.gov
Field Staff Name(Print): Ray Aliperti Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: Copy of Handwritten Report Left on Site: No
\j. r
Our observations do not relieve the contractor from performing in accordance with their contract and approved permit documents.
• •
. . . .
yr
r 10
96111 , 1 AO 1 il r III '''' 0 1H 11
di §i -its;I g kiislii 1111 1, 1 Lill ..ii , Id, ;I .:, I li
; -,:-_,= 4 .1 Olt 5 ,
<
IA , r. ?roil, Lan -g ih z5 R ii r':1111iti 1.„1. 1[
, \
:9-
15 5 7 1 ;'- '=3-8 : .-:- 9
...d•' I
e.t.
I2_1 . 04n
, 1 tr,
i 1
/..,.
E
fr.'1-4-z./1st.ClIt 4 S'i
--,-------::; „Al
/er,t
•, n Y
':-
, g•0205) . ,,../- e . 11
1
-h.,,,
;,_.: :Li QT0
\ ?0_
,..._s r •co;
r320
agg
w
, t ,
. .,.
A it 2
,..\
,\ {! v
.
h E a. -3
•,: \\ '' XS ••:--• Ie Ire tja, \--,
,• .2
74\\ = n
C___11000,_ 4114
lie=\ • L -cm ,ell--1 , r'4,..V
\\I z \
_40E--
'il ZO
‘ \ is j2W/, rii , P ab , 1 1 .
' I
\ I ; \ \ 2 .%,*/,it)E P v [&:':
4::„ ,,,, \ 1 ir,/• :11 t 1 —j V-
I .tr.—, it
)1.1 sLIE api,
, 4- ,, .z„st2, Fr-
\
_., t.\ t%
__ . 00
<fir
\:).: ic2 .1 0 pro'g r(. g. • i - ' (.5—ITS siotn- i',g: ic
I —NP ________x
0 0, - 8 i k\--- ) ) :4;1 3 >1.
_. z.. ,, ,.‘„ co. , ...„., ti —1 —Si ofil
t.i 0 .--)0, i r 9 icil0-.A..... ce U._,__,\ II
.,...t) c'.
0 w 5 /5 •
> . v j— 1 , 0 .7,_:
/,/ I2,7=7 1 •---4-= I -1.1)0/04 ...%I.
2 1,.; , ,
;A i 1k
\
- ! _licarscr "1073
;c19,2
01
"c% I ,2 I -.eta z., 'a
2 II: A
-,777,7 ,,v 5 -1— ei 2 \ / \
-\ \ ;,././/7 //A. 1z ____ 5:-..,
3
\ \\\
—1i---
t —H it; -....„, I it%
N., 1...2 i S
r----:,--) i A. '..noths.tpaarac0
Cr4ap,;iv ot ,,, c 4
a' N 4,
I
E ak. . 6
4 :
, M c4
- .:.4..,..,..—„„). „.., 2
.(13
\ - ---_-.-n=7,/,..Ht,
...
1 ,..v.
4 ..
IOW . ,P
1-77; a yo
, .:4 \
‘ 1 Llf I 1 rct.
; t ,c; ; 3.. ,„
-.; &.
...., -.. -- (.- 409
1 ' )))) s \ ,...,.."'1 1----- 14 1 1.;-V
, - 1 5 g
*i .— 1
.: . :I ;
(, = i) '7-,12:ts,
, S 101 ,v,,,
A :i
i °
.4zze. , ,
- t
Qgl----
)Sn§\--S. 4IC-1 -
f a-
6 L :. .;..,
4 . ''F-- ___-
,--- iiii
• , CE. X114i .,
I : 2,51. I,S24
,::•r*•-,, 0 i ,§ ----
:: .r:F •„•;g.:: 1 dr
.; A 8g:8 „"'I It . i; L ç
\\\/
' lib i ) •D 0,
---------
'IR ir
- N: R•gi ia,
0 \ 7/ CEIED
II;=, SIj- cIP:I
1-- ' I.
Z7141
V 7f
s \25 i
ilI t•
Cgti
\ ---7
k L ' ' "I- • 'ti II"
•,,/ ' r
\fili
i \ /
0
...ta
i.) k'S. •
kI.L
Earth
' '^s°• .; 'r 88948 Bridge Street
Engineers, Springfield, Oregon 97478
(P) 541.525.6759
Inc.
DAILY FIELD INSPECTION REPORT •
Page 1 of 1
client: E.A. White Construction Company, LLC Permit No.:City of Springfield. Date: February 25, 2013
_ 811-SPR2013-01715
Project: Candlewood Suites Hotel Project Address: 3005 Franklin EEI Report No: 13-029-42
Boulevard, Springfield, Oregon 97477
General Contractor:
E.A. White Construction Company, LLC Subcontracto Weather: Inside
Items Inspected: Bolts In Concrete (Epoxy Anchors) • New Inspection D Re-Inspection
Type of Inspections
D At Completion a In Progress D Post Completion • Continuous 0 Periodic D Other
Arrived: 9:30am Detailed Inspection Notes Departed: 10:30am
As requested by Jim Culver with E.A. White Construction Company, Earth Engineers, Inc. (EEI) representative Ray
Aliperti was on-site today to perform continuous epoxy anchor inspection on level 1 (first floor). In accordance with RFI
No. 16, a total of thirteen (13) 5/8" diameter T-1 all-thread bolts, four (4) 5/8" diameter T-2 all-thread bolts, and one (1)
7/8" diameter T-3 all-thread bolts were installed into the concrete at the locations in RFI No. 16. Prior to installation, all
holes were cleaned using compressed air and a nylon wire brush. The 2' long all-thread anchors were installed with a
minimum of 10"of embedment, and installed using Simpson Set XP Epoxy with an expiration date of July 2015.
To the best of our knowledge the epoxy anchor bolts inspected above were installed in accordance with engineer
approved RFI No. 16, and the epoxy manufacturer's directions.
•
•
Distribution (electronic distribution only):
Pete White— E.A. White Construction Company—peteweawhiteconstruction.com
Al Patel —Candlewood Suites Hotel—alpatel9 @gmail.com
Andrew Bremmeyer—Wedgewood Services Inc. —andvb@wedgwoodservices.com
Ryan Hardie—All Structures —ryanh@allstructure.com
Todd Singleton—City of Springfield—tsinqleton sprinqfield-or.qov
Robert Castile—City of Springfield—rcastile(springfield-or.qov
Field Staff Name(Print): Ray Aliperti ICC #1017075 Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: DD Copy of Handwritten Report Left on Site: No
Our inspection does not relieve the contractor from performing in accordance with their contract,approved permit documents.
•
Earth
' ,
t !. 88948 Bridge Street
y Engineers, Springfield, Oregon 97478
(P) 541.525.6759
Inc.
DAILY FIELD OBSERVATION REPORT
Page 1 of 2
Client: E.A. White Construction Company, LLC Permit No.: City of Springfield: 811- Date: February 4, 2014
SPR2013-01715
Project Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No: 13-029-38
Springfield, Oregon 97477
General contractor: E.A. White Construction Subcontractor: W.W. Construction • Weather: Cloudy
Company, LLC
Location or Items Observed: Soils Observations (Tax Lot 100) • New Observation ❑ Re-Observation
Type of Observations
❑At Completion • In Progress ❑Post Completion ❑ Continuous • Periodic ❑Other
Arrived: 9:30am Detailed Observation Notes • Departed: 10:30am
As requested by W.W. Construction, Inc., Earth Engineers, Inc. (EEI) representative Ray Aliperti was on-site today to
observe a proofroll on exposed subgrade fill soils within Tax Lot 100 (see attached site plan). Prior to conducting the
proofroll, the area had been excavated to finished subgrade elevation using a John Deere 160C LC excavator with a 4'
wide smooth bladed bucket. The excavation was performed prior to our arrival on site and according to W.W.
Construction representatives; the area was excavated to allow for 12'• of crushed rock and 3" of asphaltic concrete. The
proofroll was conducted using a fully loaded tandem axle dump truck weighing approximately 50,000 pounds. No
deflections (pumping) were observed under the wheel loads and no wheel tracking (rutting) occurred, indicating a firm,
stable subgrade at this time.
After the completion of the proofroll, the earthwork contractor immediately covered the subgrade soils with geotextile
fabric and begun placing imported 3/4••-0 crushed rock from Delta Sand and Gravel (see Photo#1 below).
To the best of our knowledge, the work observed on this date was in accordance with our previously submitted
geotechnical report entitled " Geotechnical Investigation Report, Proposed Candlewood Suites Hotel, 3005 Franklin
Boulevard, Tax-Lots 100 and 700, Springfield, Oregon, EEI Project No. 13-029-1" dated April 2, 2013; as well as our
report 13-029-37 dated January 27, 2014.
•
EEI Report No.
Februay3;4:2229,0-1 38 14
Pa f 2
t gh Q I7 Q
a
V` •n sw.. "` C 4k. j ,.Lv .-c4
..,. ,iAi
:C t 6 " l '&,-4yy���, �, . ^ h 1 Y yt�y�ry�� 7)^ t it t'
• ! MK -4 i 'S�+w°_Mr'r+ .+e. }M D { ('�Y"..R "'_y'-tre i by t• r
.v^iky,•,�.t, �.i cug ^7 •"" s , • k•
fikt` c P,^'1.i' a r �ar s e wNtArsa x• .i' 2 yn ry. yrt'` - «49r� " s awmsr A` ka 4� � r tc^- .tf t i i.,Wl;:' wt- µ �` 4 `�`� i.e4 '
;
SI .* J + x NV yn�"� r { % * Rr� � ~ ,7 Vw M',�r -�1714 ti g^$ , t",. r pa � ,rt. v t'S .^ a . 7171 t `+541 . r .way:"-; `'i fir ," $,t ` eOr2/ar/2.0!14 ` '
r�. a: ,r a > ,u a felt v :-..;;Ai-?. ..., `t . ' !`. �'`Ci�ra�s f.•
Photo #1: Tax Lot 100 area proofrolled on this date along with geotextile
fabric placement and imported 3/4"-0 crushed rock.
•
•
Attachment: February 4, 2014 Site Plan ,
Distribution (electronic distribution only):
Pete White—E.A. White Construction Company—petew(a�eawhiteconstruction.com
Al Patel— Candlewood Suites Hotel—alpatel9(a�gmail.com
Andrew Bremmeyer—Wedgewood Services Inc. —andyb(a wedgwoodservices.com
Ryan Hardie—All Structures —ryanh(ilallstructure.com
Todd Singleton—City of Springfield—tsingleton(cil springfield-or.gov
Robert Castile—City of Springfield—rcastilena sgringfield-or.gov
Field Staff Name(Print): Ray Aliperti Report Reviewed By: Troy Hull, P.E., G.E.
•
Field Staff Signature. Copy of Handwritten Report Left on Site: No•Kilo- q ,>
Our observations do not relieve the contractor from performing in accordance with their contract and approved permit documents.
li a if !i 71 , ii „ij
1 :;. L' , I
s i 5 t 7 11 t.‘ e i /VIII ...}:Jiiil Vc; 1:%,- a = -. 0 1
il ? fa ,41 ,-!ii i , 'ie. c = it -1
1; , z, t g I 1
-16: ti :,t0.11 .di .., , !!.
I: e • • ‘.f34,2,i w idi .;. si s,...11i -, ?. .! <
r, 4. i ,1 t - '-•- - _2, 37._375,[kl(,, v t : 1"" ,....il
33..:,•:317. ....-'''
..N1 D
.-.."
., . 7.—
_,---,„----- P ,- , 4)
j, =I r•-.1
3 I
. ,1-4 lb.)
..-", ' II
----- „--- _
A. ; ,
Y' ,,---- ..--' 8-11 A
-;, :' .6 `i --- „7„.<4.1 4
i,f),
, ,
„if
\ , .:--- ,, ■
I•,.'''
\,\ '. ;••• t
..,,.. • ...,_,... II 21
r
( .
, ,,
I 1
3!
7 a
• 2 \ d
---3:
--‘• • - „ft.,/ ,,,,,,„r„ .„ 0 it 1 _____t\
1,777, 7;7, ,,,,,,,, -...
n., 4 -..„<„/
i 1
,--7, \ / v/—
co __........, I
, ,, ; , 3 • ;•:•;5" - / izi— , 1. . , (-).__! ; 0 1 •-:1 t.1
\ •'P. '',-; ‘\,■• 04,/,0 ;_';; m ,„;• •. •\i' i i I .:, ,:r. :_:-A -4-
, z....,
, • \€-S-L-‘.a:\.,•.c.i
?.k.:t•.\;
'r'"•-•""A.Th../,'=o3
t
-- - !r
I) 3v
-; ,, c->a, , _! :„ i
\ „X a...
.!,v-•
74Qj
C,(e 4a n.3i 1.j.
.— Er —,— —I k r-
, , \ 1--c. 1 1 ,
1 ---1 4,t.
, . , re, 30
\ ,..\. ___c_ c -
‘ , i , ___t_____
L ‘ LI NN...bc.‘,. t
"'-- "1/; •Ie .'
■ tarrwrsabvereract-,- ......reiiirrexx_.,—Fy._•=,,,,,r,,retnen=rettty=z1:Ea-.;:nr.=----e--..prraela.erel.3 --PAo
ctig
: ,1 , , -,,, 4,,„ Alt/N., P.:-■ i ,-
I ..T..,
7 . ,
...
— — __ . !-c.! ” I 'Ml !;••.„.3 "-• 1/4 r.h k-7) ,-....,
enesaytwiiststr- --,fra:tteak,s.,,,,,;; it..7, _ ,......L,A,...
I 3 j" ■ 3, , i7; ''''irf• \\ NC:/ \
\tr.
q 'r'.• :,.:.: \ —.---i / , 1/4 8
re` i V --- ( --- -1 80 ,, :
., .. .: 7 :7... r , k.,' ---t :.,—
r ., . '25 e
1 le li git ' i I i ---.1 \\ 7.8i; 1 _
rin--- / '..'-t) ,94E7
I :, ',•,,t.j., F.,\::,c. -,..„‘„ es,1.—,,, ,.c,---1, _
.,,, W'
••; ,
It P 3
; -;:g t-7.• "31' ■•----- .----.1
•-•''3 \A L....--
• i3 ""Y r3::• Os,
t I cr'ir.i ZP,i' 431'4 1.--; (--1
i \.„, 1 _______—
tau, ,...i: tq,591. , Cre.
:.'1. C`.11,:, ...V .,. )
cr.,
\ 4,..-•,_%----; 1
, ,: z. /
,.
it ,--"---...-... ..
\ /i/
, 2"I''' rre 'Ez2re 'ei ee.lr,:e \ as*.
(341) belt ,,r,
'?
Ito
UPzD ,
d .
JAW Earth
r k 88948 Bridge Street
Engineers. Springfield, Oregon 97478
Inc. (P) 541.525.6759
DAILY FIELD OBSERVATION REPORT
Page 1 of 3
client E.A. White Construction Company, LLC Permit No.: City of Springfield: 811- Date: January 27, 2014 •
SPR2013-01715
Project: Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-37
Springfield, Oregon 97477
General Contractor: E.A. White Construction Subcontractor:W.W. Construction Weather:Cloudy
Company, LLC
Location or Items Observed: Soils Observations (Tax Lot 100) ■New Observation ❑Re-Observation
Type of Observations
❑At Completion • In Progress ❑Post Completion ❑ Continuous • Periodic ❑Other
Arrived: 1:00pm Detailed Observation Notes Departed: 3:00pm
As requested by Jim Culver with E.A. White, Earth Engineers, Inc. (EEI) representative Ray Aliperti was on-site today to
perform visual observation of exposed subgrade soils for the parking lot and driveway pavement areas within tax lot 100.
At the time of our site visit, the contractor had excavated the subgrade close to within finished subgrade in the southwest
corner of the lot (see attached site plan). The depth of the excavation ranged from 3' to 4' below existing site grade. The
excavated material, as well as the material exposed close to finished subgrade, visually appeared to be fill material
consisting of a mixture of fine-grained soils (clays and silts) ranging in color from red-brown to black. Within the fill
material were pieces of asphaltic concrete and concrete ranging in size from 4"to 18" as well as pockets of crushed rock.
Based on previously viewed documents and on-site observations, the thickness of the fill prior to any excavation may be
as much as 8' to 10' thick in some areas. At this time the parking lot and driveway pavement areas are being cut to allow
for a minimum of 12 inches of crushed rock underlain with geotextile fabric as recommended in our geotechnical report
entitled: "Geotechnical Investigation Report, Proposed Candlewood Suites Hotel, 3005 Franklin Boulevard, Tax-Lots 100
and 700, Springfield, Oregon, EEI Project No. 13-029-1" dated April 2, 2013. Prior to placing of any geotextile fabric and
crushed rock we recommended proofrolling the exposed subgrade soils to assist us in determining the stability and
firmness of the soils. The proofrolls will be scheduled at a later date as necessary.
During preparation of our geotechnical report we noted in section 1.3 - Purpose and Scope of Services that our
"recommendations for parking lot pavement sections including asphaltic concrete and crushed rock thicknesses for Tax
Lot 700 only. Access to Tax Lot 100 was not available to us at this time because it was being used as a construction
staging area for the I-5 Willamette River Bridge project". We realize it is not economical to remove and replace the 8' to
10' of fill material that underlies the parking lot and driveway pavement areas of tax lot 100. However, the owner and the
project design team need to be aware that there is a risk of future parking lot and driveway pavement distress issues (i.e.
cracking, settling, etc.) due to the underlying fill material. If the owner and the project design team want to greatly reduce
the risk of future parking lot and driveway pavement distress issues within tax lot 100, then the fill material would need to
be removed and replaced with a structural fill as described in our geotechnical report in section 3.2.
•
EEI Report No 13-029-36
January 27, 2014
Page 2 of 3
i
•
t
t �4r Ij 1 �.»:i«-� 17 G� •. - '1,I
4\ ..Lr h W r 4.. ,.
41 e..rg cam' r.\• tf&txy i y- z ¢ ff . ',' .
1 1,Y
fi s ?Tx � r y�: C.� 4 ka"
1 -4--...A., i s"G4-4 - ts.r3 i.e•Lj,ac, ' a..d. q j w1[
, +rx I 14•A a' ?x f0t /2014 x •
,...±41:1--ty ',,.}•11v .Ft. z0LC 'rr+?2 e s. a.,.
~�q� +t _1:4-• yr¢*" .1tif' g'mac-^ 'A- tf `'P t r r 1
4�AP. ) r"611 `Pose/a .rk'in"Au r�#ri- d� fie, r �-
Photo #1: Exposed parking lot and driveway subgrade in the southwest
corner of tax lot 100. View is looking towards the northeast.
,i°'C¢' -n-
a
ti nF
it a I. r ',"4 aro'#` �� ..a 3. t '+ `l �.�' =•t ,s Fxlax. rYY arl r #", _,.?.�{." 'Y,' sj. .'
r � Y tg' s` 'alit M. 4J.> ..�y. +St GaA L , ,arc O�''rC.�.' `"1'v
y
v z3.,{. T+ ^ate t,� r , 4 r 4t" •:*•0, ^�w
,p r ! t..V-�.iLr.9� 7( 91 l i t* fj,��1 r{''• 4plla. V J Xt2"�.? �,^t
r• ..s i" err"'^ ,., +Py,-y.HM 1 ✓r p i ?4
a v*ti. ., s .. �N"9`,/.•r "i�,,7�.,:.,4 _ J R„; '� ,. +'r.r-�`r
hiit!. �• +�.•En t�1 . -..e L..a:. J'�Y^T"wY s�� w
r"'4.• "i'43..w r �1... ti'-�qp 1 S ��
r xr r 6rfr 2 :1 J• s,A t.. . §r^ mIG•
��n,�vlr "i w.�. ( 7 rh .Sr t" t1 * r -
r -@•.. • dr r.4 ti.1 -t�+'”rw 3+' .s �rp e iii ti 1 ' t +
:,c4rr 1 r s r,,,` '4 w..4 i>, a are t" �` VO �Y�9
5 � �
, r>h :+r•/ . T�:.4''..,qs. --ilr °fir:a ' ,� r tr 4b t .
'�"su ,y. ✓ d :i4P...ry �a* r?ro'Sfr 't"rt"'Y� s�
Photo #2: A closer view of the exposed parking lot and driveway subgrade
in the southwest corner of tax lot 100.
EEI Report No. 13-029-36
January 27, 2014
Page 3 of 3
KIM
N.� O - rk
yy { ��. j `4,i t `� rl ft '" 4 4-1-11+ ' t w4e
{} 3� ?�y t �.�TAr,!y +* if ,t t */ F J''i s � 7 '
s h)1 > d br¢'i3CE. 5..'`p"nd Sti-� m t 1 1Y
r;;;--"1-•''';, t "P^ :3. `iftfich?+,� ti+Y. :pr"it r >4 ,yt.sy.,�,�ttt' - y il�'.
dt +,+x,. A Wed ,��.y "�� ,.y. } ���.,o r � w;l�a 19
rK w ,s"r},.i.x, W Z4ic,-`ay.„t"."."St.`.et y { .7.,'.'S�p; ''u...
^� • mss P e q�-�L+#4;: i'r.,. `' 4yzv .tw'sti .`43 T" fr-z`,
L` st ;'.:.' +3'�r`°..'(� f^tr•, r�.1. t) '-•.5;."` x�
'r .r ,r + / r y"t` 0;GI rSc�s"xr '''',.:- '21,4.. I7”,710 ti,
' ,'',.. k .4., ,:*71 ry.4.r. fi Ala r z rr v. a
.'li..•. / $.. -". -x+. t a_ti y iy.-+ewj. 3 (-'L..: ,? ill 3'r«.
Photo #3: Exposed parking lot and driveway subgrade in the southwest
corner of tax lot 100. View is looking towards the southwest.
Attachment: January 27, 2014 Site Plan
Distribution (electronic distribution only):
•
Pete White-E.A. White Construction Company-
petewaneawhiteconstruction.com
Al Patel-Br-em-ndlewood Suites Hotel -alpatel9(a)gmail.com
Andrew meyer-Wedgewood Services Inc. -andyb@wedgwoodservices.com
•
Ryan Hardie -All Structures.-ryanh c(�allstructure.com
Todd Singleton -City of Springfield-tsingleton(a� springfield-or.gov
Robert Castile -City Of Springfield-rcastile(au7springfield-or.gov
Field Staff Name(Print): Ray Aliperti Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: ` - Copy of Handwritten Report Left on Site: No
Our observations do not relieve the con�tractor�from performing in accordance with their contract and approved permit documents.
•
0 Earth
88948 Bridge Street
Engineers, Springfield, Oregon 97478
Inc.•
(P) 541.525.6759
DAILY FIELD INSPECTION REPORT
Page 1of1
Client: E.A. White Construction Company, LLC Permit No.: City of Springfield: Date: January 8, 2014
811-SPR2013-01715
Project: Candlewood Suites Hotel Project Address: 3005 Franklin EEI Report No.: 13-029-36
• Boulevard, Springfield, Oregon 97477
General Contractor: Subcontractor: Weather: Cloudy
E.A. White Construction Company, LLC
Items Inspected: Non-Shrink Grout • New Inspection 0 Re-Inspection
Type of Inspections
0 At Completion • In Progress 0 Post Completion 0 Continuous • Periodic 0 Other
Arrived: 11:30am Detailed Inspection Notes Departed: 1:30pm
As requested by Jim Culver with E.A. White Construction Company; Earth Engineers, Inc. (EEI) representative Ray
Aliperti was on-site today to perform visual inspection during non-shrink grouting under column base plates at the
following locations: eleven (11) 5x5's located at gridlines E @7, E @9, F.2 @13, F.5 @13, H @13, H.2 @13, J @12, J @10,
J @8, G @10, and G @8; and five (5) 6x6's located at gridlines F @10, F.2 @9, 1 @9, I @10, and J @10.8. The non-shrink
grout was placed as required by project details 4/S3.1 (Ext. Int. Wall Columns) and 19/S3.1(Int. Column & Ftg.). Prior to
placing the non-shrink grout the areas under the column base plates were cleaned of water and construction debris using
a vacuum. Dayton Superior 1107 Advantage Grout was used and was mixed in a "dry pack" condition in accordance with
the manufacturer's directions. The material was placed by "hand-packing" it on two sides of each column and using a
hammer and a piece of 2x4 lumber until it began to squeeze out of the other two sides. Then the other two sides were
filled using non-shrink grout and then formed by hand to match the dimensions of the base plate. In accordance with the
project details the thickness of the grout was 1-1/2" or less. A minimum compressive strength was not required per the
project plans and therefore samples for strength tests were not obtained.
To the best of our knowledge the non-shrink grout inspected above was installed in accordance with the City of
Springfield approved project plans and the installation directions of the non-shrink grout manufacturer.
Distribution (electronic distribution only):
Pete White—E.A. White Construction Company—petew(Theawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9no,gmail.com •
Andrew Bremmeyer—Wedgewood Services Inc.—andyb(ai)wedgwoodservices.com
Ryan Hardie—All Structures—ryanh(o)allstructure.com
Todd Singleton—City of Springfield—tsingleton(til springfield-or.gov
Robert Castile—City of Springfield—rcastile(&springfield-or.qov •
Field Staff Name(Print): Ray Aliperti ICC #1017075 Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: .� r ri r Copy of Handwritten Report Left on Site: NO
g'.knh' —v..% a,
•
Our inspection does not relieve the contractor from performing in accordance with their contract and approved permit documents.
Earth
88948 Bridge Street
Ai "
r 0 Engineers, Springfield, Oregon 97478
(P) 541.525.6759
Inc.
DAILY FIELD INSPECTION REPORT
Page 1 of 1
client: E.A. White Construction Company, LLC Permit No.:City of Springfield: Date: December 18, 2013
811-SPR2013-01715
Project: Candlewood Suites Hotel Project Address: 3005 Franklin BBI Report No.: 13-029-34
Boulevard, Springfield, Oregon 97477
General Contractor:
E.A. White Construction Company, LLC Subcontractor: weather: Cloudy
Items Inspected: Bolts In Concrete (Epoxy Anchors) II New Inspection 0 Re-Inspection
Type of Inspections
0 At Completion ■ In Progress 0 Post Completion • Continuous 0 Periodic 0 Other
Arrived: 1:00pm Detailed Inspection Notes Departed: 2:00pm
As requested by Jim Culver with E.A. White Construction Company, Earth Engineers, Inc. (EEI) representative Ray
Aliperti was on-site today to perform continuous epoxy anchor inspection. In accordance with RFI No. 12, a total of five
(5) 7/8" diameter all-thread bolts were installed into the concrete footings along gridline Q. The all-thread anchors were
installed with epoxy on this date because the original anchors that were placed prior to concrete placement were placed
- two feet north of their designated locations. As per RFI No. 12, a portion of the concrete stem wall at each location was
removed and 1" diameter holes drilled a minimum of 12" into the concrete footings. Prior to installation, all holes were
cleaned using compressed air and a nylon wire brush. The all-thread bolts, which were approximately 4' long, were
installed.using Simpson Set XP Epoxy with an expiration date of July 2015.
Note: The reinforcing steel bars (horizontal bars within the stem walls) exposed after concrete removal did not appear
damaged.
To the best of our knowledge the epoxy anchor bolts inspected above were installed in accordance with engineer
approved RFI No. 12, and the epoxy manufacturer's directions.
•
Distribution (electronic distribution only):
Pete White- E.A.White Construction Company-petew(5 eawhiteconstruction.com
Al Patel L Candlewood Suites Hotel-alpatel9aegmail.com
Andrew Bremmeyer-Wedgewood Services Inc. -andybewedgwoodservices.com
Ryan Hardie-All Structures-rvanheallstructure.com
Todd Singleton-City of Springfield-tsinqletone springfield-or.gov
Robert Castile-City of Springfield-rcastileespringfield-or.gov
Field Staff Name(Print): Ray Aliperti ICC #1017075 Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: ,.t ' 1 Copy of Handwritten Report Left on Site: NO
Our inspection does not relieve the contractor from performing in accordance with their contract,approved permit documents.
Earth 88948 Bridge Street
Engineers,
Inc. Springfield, Oregon 97478
(P) 541.525.6759 /
CONCRETE COMPRESSIVE STRENGTH REPORT \\
Client: E.A. White Construction Permit No.: City of Springfield: Date: December 16, 2013
Company, LLC 811-SPR2013-01715
Project: Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-29
Springfield, Oregon 97477
General Contractor: Subcontractor: Weather:Cloudy
E.A. White Construction Company, LLC
Field Data -ASTM C172
Placement Location: Hotel interior footings at the following locations: for the stairwell Sampling Location: Slab-on-grade
in the northeast corner along gridline P and 2.2; along J from 4 to 8; along I from from gridline M to Q from 9 to
101 to 12; and for the concrete slab-on-grade from gridline H to Q. 10.5
Delivery Ticket Truck#:
Tested By: R. Aliperti Supplier: Knife River #: 4004090 240340416
Date Placed: December 5, 2013 Mix Number and Proportions: 2430NEA2M0
Batch Time: --- Sample Time: 12:45pm Cement(lbs.):---
Slump(in.): 5 Water:
Batched(gal): --- Added at jobsite(gal):---
Air Content(%): --- Fine Aggregate(lbs.): ---
Material Temperature @ Sampling(°F): 58 Course Aggregate(lbs):---
Air Temp @ Sampling (°F): 37 Admixtures: Pozz80, Polyheed, NC534, Microfibre
Description of Field Curing: ASTM Field Curing Temp(°F)- High: 71 Low: 54
Date and Time Picked Up for Delivery to Lab: December 9, 2013 at 1:15pm
Comments: Concrete batch ticket was not available at the time of our test sampling. Concrete test cylinders could not
be picked up from the jobsite and transported to the laboratory until December 9, 2013 due to the jobsite being
closed due to inclement weather.
Laboratory Data -ASTM C39
Sample Test Total Load Specimen Average Specimen Compressive
EEI Lab# Age Test Date Diameter
# (lbs.) ( g
(days) Ibs Size in.) (in) Area(sq.in.) .Strength(psi)
0446 1 7 12/12/13 36,050 4X8 4.00 12.56 2,870
0447 2 28 1/02/13 4X8
0448 3 28 1/02/13 4X8
0449 4 28 1/02/13 4X8
Average f'c at 28 days =
Set#(x of y): 1 of 1 Mix Design Strength(psi): 3,000 Specified Structural Strength(psi): 3,000
Tested By: Carlson Testing Inc.
• Specimens made by EEI rep. • Specimens delivered by EEI rep. ❑ Test results comply with project specs.
❑ Specimens made by others: ❑ Specimens delivered by others: ❑ Test results do not comply with project
specs.
Report Reviewed By (print name): Troy Hull
Report Reviewed By (signature):
t)G6:c--'Q G •
Distribution List(via email unless specified otherwise):
Pete White—E.A. White Construction Company—petew@eawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9(cilgmail.com
Andrew Bremmeyer—Wedgewood Services Inc.—andyb(rJwedowoodservices.com
Ryan Hardie—All Structures—ryanhAallstructure.com
Todd Singleton—City of Springfield—tsingleton(&springfield-or.gov
Robert Castile—City of Springfield—rcastite espringfield-or.qov
Earth
88948 Bridge Street
Engineers, Springfield, Oregon 97478
(P) 541.525.6759
Inc.
DAILY FIELD REPORT
Page 1 of 1
diem: E.A. White Construction Company, LLC Permit No: City of Springfield: Date: December 16, 2013
811-SPR2013-01715
Project: Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-33 •
Springfield, Oregon 97477
General Contractor: Subcontractor: Weather:Partly Cloudy,
E.A. White Construction Company, LLC
Arrived: 1:15pm Detailed Notes Departed: 1:30pm
Earth Engineers, Inc. (EEI) representative Ray Aliperti was on-site this date to pick-up one set of four (4x8) concrete test
samples that were cast on December 13, 2013. The samples were transported to the laboratory for final storage and
compression testing in accordance with ASTM procedures. The results of the compression tests will be presented in a
separate EEl report no. 13-029-32.
•
•
Distribution (electronic distribution only):
Pete White—E.A.White Construction Company—peteweawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9(@gmail.com
Andrew Bremmeyer—Wedgewood Services Inc.—andybPwedgwoodservices.com
Ryan Hardie—All Structures—rvanh(o)allstructure.com
City of Springfield—Todd Singleton—tingleton(c,ci.springfield.or.us
Robert Castile—City of Springfield—rcastile(aspringfield-or.nov
Field Staff Name(Print): Ray Aliperti Report Reviewed By: Tray Hull, P.E., G.E.
Field Staff Signature: i Copy of Handwritten Report Left on Site: No
Rat9 `�
•
•
Earth 88948 Bridge Street
3' ` Engineers, Springfield, Oregon 97478
(P) 541.525.6759
CONCRETE COMPRESSIVE STRENGTH REPORT
Client: E.A. White Construction Permit No.: City of Springfield: Dale: December 16, 2013
Company, LLC 811-SPR2013-01715
Project: Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-26
Springfield, Oregon 97477
General Contractor:
Subcontractor Weather: Cloudy
E.A. White Construction Company, LLC
Field Data -ASTM C172
Placement Location: Hotel interior pad footings at gridlines G at 7.2, G at sampling Location: Same as placement
8.2, and J at 10.8: as well as the following exterior footings and stem location
walls: along gridline 12 from E5 to F.2, F.2 from 12 to 13, 13 from F.2
to F.5. F.5 from 13 to 13.5, 13.5 from F.5 to H, H from 13 to 13.5, 13
from H to H.8, H.8 from 12 to 13, and 12 from H.8 to J.5.
Tested By: R. Alipertl Supplier: Knife River Delivery Ticket#:
4004077 Truck#: 240340382
Date Placed: December 4, 2013 Mix Number and Proportions: 2430NEA2MQ
Batch Time: 12:51 pm Sample Time: 1:45pm Cement(lbs.):2,575
Water:
Slump(in,). 3-1/2 Batched(gal): 110 Added atjobsite(gal): ---
Air Content(%): --- Fine Aggregate(lbs.): 8,930
Material Temperature @ Sampling(°F): 58 Course Aggregate(lbs): 10,940
Air Temp @ Sampling (°F): 37 Admixtures: Pozz80, Polyheed
Description of Field Curing: ASTM Field Curing Temp(°F)- High: 71 Low: 54
Dale and Time Picked Up for Delivery to Lab: December 5, 2013 at 4:15pm
•
Comments:
Laboratory Data -ASTM C39
Sample Test Total Load Specimen Average Specimen Compressive
EEI Lab# Age Test Date Diameter Size(in.) Area(sq.in.) Strength
(psi)
(in.)
0442 1 7 12/11/13 44,210 4X8 4.00 12.56 3,520
0443 2 29 1/02/13 4X8
0444 3 29 1/02/13 4X8
0445 4 29 1/02/13 4X8
Average f'c at 28 days =
Set#(x of y): 1 of 1 Mix Design Strength(psi): 3,000 Specified Structural Strength(psi): 3,000
Tested By: Carlson Testing Inc.
•
• Specimens made by EEI rep. • Specimens delivered by EEI rep. ❑ Test results comply with project specs.
❑ Specimens made by others: ❑ Specimens delivered by others: ❑ Test results do not comply with project
specs.
Report Reviewed By(print name): Troy Hull
Report Reviewed By (signature): �c�:�r.�
Distribution List(via email unless specified otherwise):
Pete White—E.A.White Construction Company—petew(cileawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel90gmail.com
Andrew Bremmeyer—Wedgewood Services Inc. —andybt&wedgwoodservices.com
Ryan Hardie—All Structures—ryanhaallstructure.com
Todd Singleton—City of Springfield—tsingleton(fi)springfield-or.gov
Robert Castile—City of Springfield—rcastilesprinqfield-or.qov
•
Earth
88948 Bridge Street
Engineers,
Inc. Springfield, Oregon 97478
(P) 541.525.6759
DAILY FIELD INSPECTION REPORT
Page 1 of 1
Client E.A. White Construction Company, LLC Permit No.:City of Springfield: Date: December 13, 2013
811-SPR2013-01715 _
Project: Candlewood Suites Hotel
Project Address:3005 Franklin EEI Report No.: 13-029-31
Boulevard, Springfield, Oregon 97477
General Contractor: Subcontractor: Weather: Partly Cloudy
E.A. White Construction Company, LLC
Items Inspected: Reinforcing Steel m New Inspection ❑ Re-Inspection
_ Type of Inspections
m At Completion ❑ In Progress ❑Post Completion ❑ Continuous •Periodic ❑Other
Arrived: 9:00am Detailed Inspection Notes Departed: 10:45am
As requested by Jim Culver with E.A. White Construction Company, Earth Engineers, Inc. (EEI) representative Ray
Aliperti was on-site today to perform periodic visual inspection of reinforcing steel for the hotel interior footings at the
following locations: stairwell in the southwest corner along gridline C.7 and 10.5; along gridline G from 6 to 8.8; and along
F from 10 to 12. Reinforcing steel was inspected for grade, size, lap, placement, and clearances where applicable. The
reinforcing steel was secured against displacement using tie wire and supported on plastic chairs to maintain proper
clearances.
Note: The contractor asked us to note that a vapor barrier had been placed over the exposed crushed rock surface
beneath the proposed concrete slab-on-grade being poured today from gridline A to H; electrical conduit was placed for
the proposed hotel exercise room and lobby, and that all ice and snow was removed prior to placement of concrete today.
While on site we also cast one set of concrete placed in the above footing locations as well as the concrete slab-on-grade
from gridline A to H. As per the approved project plans, continuous inspection during the placement of concrete was not
required. One set of four (4" X 8") concrete test cylinders were cast from Knife River's mix no. 2430NEA2M0 (3,000psi,
no air, with midrange reducer) placed in the above locations on this date. The test cylinders were placed in a cooler and
stored in the contactor's office (temperature set at 55° F) for initial storage. Due to the jobsite being closed for the
weekend, they will be picked up on Monday December 16, 2013 and transported to the laboratory for final storage and
compression testing. One test cylinder will be tested at 7-days and the remaining three cylinders tested at 28-days. The
results of those tests along with more detailed concrete information (i.e. time sampled, concrete temperature, etc.) will be
presented in a separate EEI report no. 13-029-32. The sample we obtained had a measured slump of 5".
To the best of our knowledge the reinforcing steel inspected above was in accordance with the City of Springfield
approved project plans.
Distribution (electronic distribution only):
Pete White—E.A.White Construction Company—petew(cileawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9(o�gmail.com
Andrew Bremmeyer—Wedgewood Services Inc.—andyb(o�wedgwoodservices.com
Ryan Hardie—All Structures—ryanh(a,allstructure.com
City of Springfield—Todd Singleton—tsinoleton aOci.springfield.or.us, Robert Castile—City of Springfield—rcastile(d)a springfield-or.gov
Field Staff Name(Print): Ray Aliperti ICC #1017075 Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: t) h Copy of Handwritten Report Left on Site: No
�rA�-tn� y,I VI
Our inspection does not relieve the contractor from performing in accordance with their contract and approved permit documents.
•
Earth 88948 Bridge Street
•Engineers, Springfield, Oregon 97478
Phone 541.525.6759
Inc. Fax 541.896.3070
CONCRETE COMPRESSIVE STRENGTH REPORT
Client: E.A. White Construction Permit No.: City of Springfield: Date: December 12, 2013
Company, LLC 811-SPR2013-01715
Project: Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-23
Springfield, Oregon 97477
General Contractor: Subcontractor: Weather: Partly Cloudy
E.A. White Construction Company, LLC
Field Data -ASTM C172
Placement Location:Hotel interior footings except at the following
locations: stairwell in the southwest corner along gridline C.7 Sampling Location: Hotel interior footings on gridline
and 10.5, stairwell in the northeast corner along gridline P and 3 from N to O: 7 from N to O; 9 from N to O; P
2.2, along gridline G from 6 to 8.8, along J from 4 to 8, along F from 10 to 12; and N from 3 to 9
from 10 to 12, and alon._ I from 10.7 to 12
Tested By: R. Aliperti Supplier: Knife River Delivery Ticket#: 4025908 Truck#: 240340554
Date Placed: October 27, 2013 Mix Number and Proportions: 2430NEA2M0
Batch Time: 12:15pm Sample Time: 12:55pm Cement(lbs.):4,580
Slump(in.): 5 • Water:
Batched(gal): 126 Added at jobsite(gal): ---
Air Content(%): --- Fine Aggregate(lbs.): 16,560 •
Material Temperature @ Sampling(°F): 53 Course Aggregate Ohs): 19,640
Air Temp @ Sampling (°F):49 Admixtures: Pozz80, Polyheed
Description of Field Curing: ASTM Field Curing Temp(°F)- High: 60 Low: 51
Date and Time Picked Up for Delivery to Lab: November 29, 2013 at 1:30pm
Comments:
Laboratory Data -ASTM C39
Sample Test Total Load Specimen Average Specimen Compressive
EEI Lab# Age Test Date Diameter
# (days) (lbs.) Size(in.) On.) Area(sq. in.) Strength(psi)
0437 1 7 12/04/13 33,160 4X8 4.00 12.56 2,640
0438 2 29 12/26/13 4X8
0439 3 29 12/26/13 4X8
0440 4 29 12/26/13 4X8
Average f'c at 28 days =
Set#(x of y): 1 of 1 Mix Design Strength(psi): 3,000 Specified Structural Strength(psi): 3,000
Tested By: Carlson Testing Inc.
• Specimens made by EEI rep. • Specimens delivered•by EEI rep. ❑ Test results comply with project specs.
❑ Specimens made by others: ❑ Specimens delivered by others: ❑ Test results do not comply with project
specs
Report Reviewed By (print name): Troy Hull
Report Reviewed By (signature):
Distribution List(via email unless specified otherwise):
Pete White—E.A.White Construction Company—petew@2eawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatelgedmail.com
Andrew Bremmeyer—Wedgewood Services Inc.—andyb@cilwedgwoodservices.com
Ryan Hardie—All Structures—rvanh@allstructure.com
Todd Singleton—City of Springfield—tsinoletonc Springfield-or.gov
Robert Castile—City of Springfield—rcastilesprinqfield-or.qov
Earth
88948 Bridge Street
Engineers, Springfield, Oregon 97478
(P) 541.525.6759
•
Inc.
DAILY FIELD INSPECTION REPORT
Page 1 of 1
Client: E.A. White Construction Company, LLC Permit No.: City of Springfield: Date: December 5, 2013
811-SPR2013-01715
Project: Candlewood Suites Hotel Project Address: 3005 Franklin EEI Report No.: 13-029-28
Boulevard, Springfield, Oregon 97477
General Contractor: Subcontractor: Weather:Cloudy
E.A. White Construction Company, LLC
Items Inspected: Reinforcing Steel •New Inspection D Re-Inspection
Type of Inspections
•At Completion 0 In Progress 0 Post Completion 0 Continuous • Periodic D Other
Arrived: 12:15pm Detailed Inspection Notes Departed: 1:30pm
As requested by Jim Culver with E.A. White Construction Company, Earth Engineers, Inc. (EEI) representative Ray
Aliperti was on-site today to perform periodic visual inspection of reinforcing steel for the hotel interior footings at the
following locations: stairwell in the northeast corner along gridline P and 2.2; along J from 4 to 8; and along I from 10.7 to (
12. Reinforcing steel was inspected for grade, size, lap, placement, and clearances where applicable. The reinforcing
steel was secured against displacement using tie wire and supported on plastic chairs to maintain proper clearances.
We also cast one set of concrete placed in the above locations as well as for the concrete slab-on-grade being poured
from gridline H to Q. As per the approved project plans, continuous inspection during the placement of concrete was not
required. One set of four (4" X 8") concrete test cylinders were cast from Knife River's mix no. 2430NEA2MO (3,000psi,
no air, with midrange reducer) placed in the above locations on this date. The test cylinders were placed in a cooler and
stored in the contactors office (temperature set at 55° F) for initial storage and will be picked up within 48 hours and
transported to the laboratory for final storage and compression testing. One test cylinder will be tested at 7-days and the
remaining three cylinders tested at 28-days. The results of those tests along with more detailed concrete information (i.e.
time sampled, concrete temperature, etc.) will be presented in a separate report. The sample we obtained had a
measured slump of 5".
•
To the best of our knowledge the work inspected above was in accordance with the City of Springfield approved project
plans.
Distribution (electronic distribution only):
Pete White—E.A.White Construction Company—petew(c)eawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9 a(�,gmail.com
Andrew Bremmeyer—Wedgewood Services Inc.—andybna wedgwoodservices.com
Ryan Hardie—All Structures—ryan heal lstructure.com
City of Springfield—Todd Singleton—tsingleton eci.springfield.or.us
Robert Castile—City of Springfield—rcastile(a?springfield-or.gov
Field Staff Name(Print): Ray Aliperti ICC #1017075 Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: R Copy of Handwritten Report Left on Site: No
Our inspection does not relieve the contractor from performing in accordance with their contract and approved permit documents. •
•
Earth
O 88948 Bridge Street
Engineers, Springfield, Oregon 97478
(P) 541.525.6759
Inc.
. DAILY FIELD REPORT
Page 1 of 1
Client: E.A. White Construction Company, LLC Permit No.: City of Springfield: Date: December 5, 2013
811-SPR2013-01715
Project Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-27
Springfield, Oregon 97477
General Contractor Subcontractor: Weather:Cloudy
E.A. White Construction Company, LLC i
Arrived: 4:15pm Detailed Notes Departed: 4:30pm
Earth Engineers, Inc. (EEI) representative Ray Aliperti was on-site this date to pick-up one set of four (4x8) concrete test
samples that were cast on December 4 2013. The samples were transported to the laboratory for final storage and
compression testing in accordance with ASTM procedures. The results of the compression tests will be presented under
separate cover.
•
•
Distribution (electronic distribution only):
Pete White—E.A.White Construction Company—petew(aeawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9(aegmail.com
Andrew Bremmeyer—Wedgewood Services Inc.—andybewedgwoodservices.com
Ryan Hardie—All Structures—rvanhaallstructure.com
City of Springfield—Todd Singleton—tsingleton(ahci.sprindfield.or.us
Robert Castile—City of Springfield—rcastile(Thspringfield-or.gov
Field Staff Name(Print): Ray Aliperti Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: Copy of Handwritten Report Left on Site: No
I\,11-1•�,.) \I. ��
Earth
88948 Bridge Street •
Engineers, Springfield, Oregon 97478
(P) 541.525.6759
Inc.
DAILY FIELD INSPECTION REPORT
Page 1 of 1
Client: E.A. White Construction Company, LLC Permit No.: City of Springfield: Date: December 4, 2013
811-SPR2013-01715
Project: Candlewood Suites Hotel Project Address: 3005 Franklin EEI Report No.: 13-029-25
Boulevard, Springfield, Oregon 97477
General Contractor:
E.A. White Construction Company, LLC Subcontractor: Weather Cloudy
Items Inspected: Reinforcing Steel, Anchor Bolts, and Concrete Forms • New Inspection ❑ Re-Inspection
Type of Inspections
®Al Completion ❑ In Progress ❑Post Completion ❑ Continuous ''• Periodic ❑Other
Arrived: 12:00pm Detailed Inspection Notes Departed: 2:00pm
As requested by Jim Culver with E.A. White Construction Company, Earth Engineers, Inc. (EEI) representative Ray
Aliperti was on-site today to perform periodic visual inspection of reinforcing steel, anchor bolts, and concrete forms for
the hotel interior pad footings at gridlines G at 7.2, G at 8.2, and J at 10.8; as well as the following exterior footings and
stem walls: along gridline 12 from E.5 to F.2, F.2 from 12 to 13, 13 from F.2 to F.5, F.5 from 13 to 13.5, 13.5 from F.5 to
H, H from 13 to 13.5, 13 from H to H.8, H.8 from 12 to 13, and 12 from H.8 to J.5. Reinforcing steel and anchor bolts were
inspected for grade, size, lap (reinforcing steel only), placement, and clearances where applicable. The reinforcing steel
and anchor bolts were secured against displacement using tie wire and wooden templates. Plastic chairs were used
under the reinforcing steel bars to maintain proper clearances. The interior of the forms were clean and free of debris and
were sized in accordance with the approved project plans.
We also cast one set of concrete placed in the above locations. As per the approved project plans, continuous inspection
during the placement of concrete was not required. One set of four (4" X 8") concrete test cylinders were cast from Knife
River's mix no. 2430NEA2M0 (3,000psi, no air, with midrange reducer) placed in the above locations on this date. The
test cylinders were placed in a cooler and stored in the contactor's office (temperature set at 55° F) for initial storage and
will be picked up within 48 hours and transported to the laboratory for final storage and compression testing. One test
cylinder will be tested at 7 days and the remaining three cylinders tested at 28 days. The results of those tests along with
more detailed concrete information (i.e. time sampled, concrete temperature, etc.) will be presented in a separate report.
The sample we obtained had a measured slump of 3-1/2".
To the best of our knowledge the work inspected above was in accordance with the City of Springfield approved project
plans.
•
Distribution (electronic distribution only):
Pete White—E.A.White Construction Company—petew{e)eawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9(hgmail.com
Andrew Bremmeyer—Wedgewood Services Inc.—andybei wedgwoodservices.com
Ryan Hardie—All Structures—rya nh{U7allstructu re.com
•
City of Springfield—Todd Singleton-tsingleton(cilci.springfeld.or.us
Robert Castile—City of Springfield—rcastile(a�springfeld-or.gov
Field Staff Name(Print): Ray Aliperti ICC #1017075 Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: I> •I� 1
L Copy of Handwritten Report Left on Site: NO
• -p.V V SJ n t
Our inspection does not relieve the contractor from performing in accordance with their contract and approved permit documents.
•
•
Earth
88948 Bridge Street
Engineers. Springfield, Oregon 97478
Phone 541.525.6759
InC. Fax 541.896.3070
DAILY FIELD REPORT •
Page 1 of 1
client: E.A. White Construction Company, LLC Permit No.: City of Springfield: Date: November 29, 2013
811-SPR2013-01715
-
Project: Candlewood Suites Hotel Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-24
Springfield, Oregon 97477
General Contractor: Subcontractor: Weather: Cloudy
E.A. White Construction Company, LLC
Arrived: 1:30pm Detailed Notes Departed: 1:45pm
Earth Engineers, Inc. (EEI) representative Ray Aliperti was on-site this date to pick-up one set of four (4x8) concrete test
samples that were cast on November 27, 2013. The samples were transported to the laboratory for final storage and
compression testing in accordance with ASTM procedures. The results of the compression tests will be presented under •
separate cover.
•
•
Distribution (electronic distribution only):
. Pete White—E.A.White Construction Company—petew(a)eawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9@nmail.com
Andrew Bremmeyer—Wedgewood Services Inc.—andybewedgwoodservices.com
Ryan Hardie—All Structures—rvanh 5 allstructure.com
City of Springfield—Todd Singleton—tsingleton anci.sprinofield.or.us
Robed Castile—City of Springfield—rcastile@springfield-or.gov
Field Staff Name(Print): Ray Aliperti Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: Copy of Handwritten Report Left on Site: No
•
Earth •
,car y+_.; _ 88948 Bridge Street
'it En it ears; Springfield, Oregon 97478
V (P) 541.525.6759
Inc.
DAILY FIELD INSPECTION REPORT
Page 1 of 1
Client: E.A. White Construction Company, LLC Permit No.: City of Springfield: Date: November 27, 2013
811-SPR2013-01715
Project: Candlewood Suites Hotel Project Address: 3005 Franklin EEI Report No.: 13-029-22
Boulevard, Springfield, Oregon 97477
General Contractor:
Subcontractor Weather: Partly Cloudy
E.A. White Construction Company, LLC
Items Inspected: Reinforcing Steel, Anchor Bolts, and Concrete Forms • New Inspection ❑ Re-Inspection
Type of Inspections
m At Completion C In Progress C Post Completion C Continuous • Periodic C Other
Arrived: 11:30am Detailed Inspection Notes Departed: 1:30pm
As requested by Jim Culver with E.A. White Construction Company, Earth Engineers, Inc. (EEI) representative Ray
Aliperti was on-site today to perform periodic visual inspection of reinforcing steel, anchor bolts, and concrete forms for
the hotel interior footings except at the following locations: stairwell in the southwest corner along gridline C.7 and 10.5,
stairwell in the northeast corner'along gridline P and 2.2, along gridline G from 6 to 8.8, along J from 4 to 8, along F from
10 to 12, and along I from 10.7 to 12. At these locations the footings will be poured monolithically during the placement of
the concrete slab-on-grade. Reinforcing steel and anchor bolts were inspected for grade, size, lap (reinforcing steel only),
placement, and clearances where applicable. The reinforcing steel and anchor bolts were secured against displacement
using tie wire and wooden templates. Plastic chairs were used under the reinforcing steel bars to maintain proper
clearances. The interior of the forms were clean and free of debris and were sized in accordance with the approved
project plans.
We also cast one set of concrete placed in the above locations. As per the approved project plans, continuous inspection
during the placement of concrete was not required. One set of four (4" X 8") concrete test cylinders were cast from Knife
River's mix no. 2430NEA2M0 (3,000psi, no air, with midrange reducer) placed in the interior footings on this date. The
test cylinders were left on-site in a cooler for initial storage and will be picked up within 48 hours and transported to the
laboratory for final storage and compression testing. One test cylinder will be tested at 7-days and the remaining three
cylinders tested at 28-days. The results of those tests along with more detailed concrete information (i.e. time sampled,
concrete temperature, etc.) will be presented in a separate report. The sample we obtained from the first concrete truck
had a measured slump of 5".
To the best of our knowledge the work inspected above was in accordance with the City of Springfield approved project
plans.
Distribution (electronic distribution only):
Pete White—E.A.White Construction Company—petew@eawhiteconstruction.com
Al Patel—Candlewood Suites Hotel—alpatel9(a email.corn
Andrew Bremmeyer=Wedgewood Services Inc. —andyb(&wedgwoodservices.com
Ryan Hardie—All Structures—ryanhtcallstructure.com
City of Springfield—Todd Singleton—tsinoletoneci.springfield.or.us
Robert Castile—City of Springfield—rcastile(@sprinefield-or.gov
Field Staff Name(Punt): Ray Aliperti ICC #1017075 Report Reviewed By: Troy Hull, P.E., G.E.
Field Staff Signature: Copy of Handwritten Report Left on Site: No
vo_wiev
Our inspection does not relieve the contractor from performing in accordance with their contract and approved permit documents.
•