HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2013-11-19 Earth 88948 Bridge Street
Engineers, Springfield, Oregon 97478
Phone 541.525.6759
Inc. Fax 541.896.3070
•
CONCRETE COMPRESSIVE STRENGTH REPORT
client: E.A. White Construction Permit No.: City of Springfield: Date: November 19, 2013
Company, LLC 811-SPR2013-01715
Project: Candlewood Suites Hotel Project Address: 3005 Franklin Boulevard, EEI Report No.: 13-029-14
Springfield, Oregon 97477
General Contractor: E.A. White
Construction Company, LLC Subcontractor: Weather: Clear
Field Data -ASTM C172
Placement Location: All exterior hotel building footings including Sampling Location: Bottom 4"to 6" of footings
pad footings except for footings between gridlines F and J from (first lift)
12 to 13.
Tested By: R. Aliperti Supplier: Knife River Delivery Ticket#: 4025400 Truck#:
24400 3 340394
Date Placed: October 21, 2013 Mix Number and Proportions: 2430NEA2M0
Batch Time: 12:38pm Sample Time: 1:35pm Cement(lbs.): 4,580
Water:
Slump(in.): 5-1/2 Batched(gal): 186 Added at jobsite(gal): ---
Air Content rip): --- Fine Aggregate(lbs.): 15,791
Material Temperature @ Sampling(°F): 64 Course Aggregate(lbs): 19,360
Air Temp @ Sampling (°F): 65 Admixtures: Pozz80, Polyheed
Description of Field Curing: ASTM Field Curing Temp(°F)- High: 72 Low: 64
Date and Time Picked Up for Delivery to Lab: October 23, 2013 at 10:30am
Comments:
Laboratory Data -ASTM C39
Sample Test Total Load Specimen Average Specimen Compressive
Lab# Age Test Date Diameter
(lbs.) (in.) g
(days) Ibs Size in.) (in) Area(sq. in.) Strength(psi)
0429 1 7 10/28/13 40,500 4X8 3.99 12.50 3,240
0430 2 28 . 11/18/13 60,410 4X8 4.00 12.56 4,810
0431 3 28 11/18/13 61,920 4X8 4.00 12.56 4,930
0432 4 28 11/18/13 57,150 4X8 4.00 12.56 4,550
Average f'c at 28 ' days = 4,760
Set#(x of y): 1 Of 1 Mix Design Strength(psi): 3,000 Specified Structural Strength (psi): 3,000
Tested By: Carlson Testing Inc. •
•
• Specimens made by EEI rep. • Specimens delivered by EEI rep. • Test results comply with project
specs.
El Specimens made by others: ❑ Specimens delivered by others: ❑ Test results do not comply with
project specs.
Report Reviewed By (print name): Troy Hull
Report Reviewed By (signature): -----^d 9
Distribution List (via email unless specified otherwise):
Pete White-E.A. White Construction Company-petewcZDeawhiteconstruction.com
Al Patel-Candlewood Suites Hotel-alpatel9 gmail.com
Andrew Bremmeyer-Wedgewood Services Inc.-andvbCilweduwoodservices.com
Ryan Hardie-All Structures-rvanh(a.allstructure.com
City of Springfield-Todd Singleton-tsingleton a( ci.springfield.or.us
City of Springfield- Robert Castile-rcastilec Springfield-onus