Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Miscellaneous Field Test & Inspection Report 2013-10-3
REQUEST FOR PROPOSAL Project: Kingsford Manufacturing Break/Locker Room Renovation RFP Number: 01 3315 Marcola Road Springfield, OR Date: 3 October 2013 To: McKenzie Commercial A/E Project Number: 1308 Attention: Toby DeMasters �n Contract For: Renovations From: Scott Stolarczyk, AIA (// /'1�2D/,3—D/7�{o RobertsonISherwoodlArchitects pc This Request for Proposal (RFP) contains an itemized quotation for changes in the Contract Sum and/or Time in response to proposed modifications to the Contract Documents and/or based on Request for Information No: • Description of Proposed Change: Provide steel support around the new door opening on the south wall of Mens Locker 103 (Door 103A) as shown on the attached Drawing. • • Attachment: RFP-01 Detail Sheets 1 and 2, dated 26 September 2013 Reason For Change: Existing conditions Proposed Change in Contract Sum: Proposed Change in Contract Time: Attached is supporting information from: Contractor Subcontractor Supplier Copies to: Owner Consultants Field • Signed for: McKenzie Commercial by: Date: Architect Recommendation for Approval: Yes No Date: Owner Authorization to Proceed and Prepare Change Order: Yes No Date: EXISTING CMU WALL ©11, OTYP. © SIM. I I CI I I I•ip/I 1•I I I I I I I I I 1!• - • -71 L I I r — — 7 1 I - °> I I4 . 1 I / 1I IIII Ilrp -II III • /® I I II, iii WINE NEW OPENING PER NEW HSS 4x2x} ARCHITECTURAL FRAME DRAWINGS o REINFORCEMENT AT CMU WALL OPENING W SCALE: NONE TYP. AT SIDES I S� T URA z HSS HEADER 'IL 3/16 TYP. T&B �°"� —HSS JAMB 1/ OREGON . . 9/O °Fa. 30, 2-�, Q�� © WELD CONNECTIONS 99D0 HEO'' ✓ SCALE: 1i"=7 '-0" Expires:JUNE 30,2015 Drawn By JLB OPENING Robertson' SherwoodlArchitects pc Se Checked 132 East Broadway,Suite 540 P 554411:334452.48300727 www.robertsonsherwood.com x? rpm RH SUPPORT Eugene,Oregon 9]401 F5411345.4302 -*`,' 1`rm ICJ j7 Date DETAIL SHT. 1 Kingsford Manufacturing- t 26 SEPT 2013 g 9 �� Prefect Break/Locker Room Renovations 1 13-134 3315 Marcola Road,Springfield,OR 97477 EXISTING • III BASE IL' w/ ANCHOR, $' ' ' 8" CMU WALL SEE DETAIL ( NEW JAMB FRAMING VERIFY OR . TITEN HD PROVIDE SOLID ANCHOR AT 4848 .L' GROUT AT CELLS EMBED 32" UI w/ NEW ANCHOR i" DIA. I r THREADED ROD A w/ '`SIMPSON" SET—XP ADHESIVE EMBED 32° MIN. AI 112"" If 7"x2-1"x 4" o JAMB © SCALE: is"=1 '-0" VERIFY OR PROVIDE 0 SOLID GROUT AT i ... :'..0 CELLS w/ NEW NEW HEADER $ ::. ANCHOR FRAMING 7. :' , 0 EXISTING `• '`1 8" CMU WALL f " TITEN HD ' ,, _ ANCHOR AT _ 'Y 16"o.c. EMBED J<;• % _s PU C T UR, 3k 7",..t:-2.7,,,, S) B.. MIN. VV[11�1 J . - .. V r'R5� 0INA, • NEW JAMB 1-..-.'.--': `C.�i' FRAMING �` ` -V092PE• BEYOND 7.-,.. .•r.• OREGON 9/C AFC. 30, 4c ' O<Q •Q HEADER 99490 HE0 © SCALE: i"=1 '-0" Expires:JUNE 30,2015 Drawn By JLB OPENING RobertsonlSherwoodlArchitects pc sat Checked RH SUPPORT Eugene,Oregon 97401i1e 540 F 5411345.4002 www.roder[sonstlerwoodcom � a { FP Date DETAIL SHT. 2 Kingsford Manufacturing- 26 SEPT 2013 g 9` Project Break/Locker Room Renovations 13-134 3315 Marcoia Road,Springfield,OR 97477