Loading...
HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2013-8-2 Page 1 of 1 TESTING e INSPEETION,tar. Geot,cHdml&csnsesc,{onSerdae, Geotechnical&ConstructionServices Field Density Test Results - ASTM D 2922 Client: Mr. Dan McIntyre Project: Dr. Stambaugh Dental Office Date: 08-02-13 McIntyre Construction 1863 Laura St. Project No.: 2137139 90472 Woodruff Street Springfield, Oregon Report No.: E-34562 Eugene, Oregon 97402 B.P. No.: 811-LDP2013-00056 MOISTURE/DENSITY DATA: ASTM D698 - Maximum Dry Density of 125.9 pcf, at 12.6% moisture furnished by contractor. Wet Dry Test Approximate Location Approx. Density Percent Density Percent Compaction No. ' Elev. (pcf) Moisture (pcf) Compaction Requirement 1 Near southeast corner FG 133.7 4.5 127.9 100+ 95 2 Near center of east side- FG 138.7 3.9 133.5 100+ 95 3 Near northeast corner FG 137.8 4.1 132.4 100+ 95 4 Near center of north side FG 143.0 4.3 137.2 100+ 95 5 Near northwest corner FG 139.4 3.7 134.5 100+ 95 6 Near center of west side FG 143.0 4.9 137.2 100+ 95 7 Near southwest corner FG 128.1 4.5 122.7 98 95 8 Near center of south side FG 1323 4.8 126.3 100+ 95 Tests performed at finished grade of base rock under perimeter continuous footings. Remarks: Dan McIntyre (McIntyre Construction)was advised of test results. , Reviewed By: Michael L. Meyer Technical Manager c: City of Springfield — Robert Castile (email) • MLM:sn • This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such.information contained herein shall not be reproduced in pan of full and/or any pan thereof be disclosed without FEI Testing&Inspection,Inc.'s written authorization. 750 NW Correll Avenue•Corvalliis,Oregon 97330.phone(541)757-4698•fax(541)757-2991 29540 B Mint Road•Eugene,°awn97402•phone(541)684-3849-fax(541)6843851 62979 NE Plateau Drive,Suite 3 Bend,Oregon 97701 phone(541)382-4844•fax(541)382-4846