HIGH-EFFICIENCY LIGHTING SYSTEMS
OREGON RESIDENTIAL SPECIALTY CODE (ORSC)
Permit No.: 9 l t - 5PZ ZD I — o0513Jurisdiction
Site Address: 534.1 V 57Y1I t y 5/Ftn Oz 91 VI is
Subdivision/Lot: TES 1'N itAc£ I-or -' ?J
and/or
Map and Tax Lot: •
By my signature below, I certify that a minimum of❑ fifty (50) percent, *❑ seventy-five (75)percent, of
the permanently installed lighting fixtures in the above mentioned building have been installed with compact
or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon
Residential Specialty Code N1107.2)1
* Check the 75% box if the additional measure selected to comply with ORSC Ni 101.1 and Table
N1101.1(2) requires 75% of lighting fixtures to have energy efficient lamps.
Signed: L Date: 't/Q113
Owner/General Contractor/Authorized Agent
Print
Name: S COLT 5
Contractor's CCB # Expiration Date:
•
1 ORSC Section NI 107.2. High-Efficiency Lighting Systems. A minimum of fifty(50)percent of the permanently installed
lighting fixtures, seventy-five (75%)percent, if the selected additional energy code measures in the Table N1101.1(2)requires
greater lighting efficiency, shall be installed with compact or linear fluorescent, or a lighting source that has a minimum efficacy of
40 lumens per input watt. Screw-in compact fluorescent lamps comply with this requirement.
The Building official shall be notified in writing at the final inspection that a minimum of the required percentage of the
permanently installed lighting fixtures are compact or linear fluorescent, or a minimum efficacy of 40 lumens per input watt.
C:\High-Efficiency lnter.doc
SPRINGFIELD
:. .
çIT±tOF SPRINGFIELD, OREGON
DEVELOPMENT SERVICES DEPARTMENT �.� `« $ li.
225 FIFTH STREET
SPRINGFIELD, OR 97477
(541) 726-3753
Moisture Content Acknowledgement Form
I, S&PT DAvts , am the general contractor or the owner-builder
at the following address:
5Tour
Street Address
40,/-4Fah& / (A 5ir)3
City
S l l -- 5722013 - 00573
Permit#
If applicable:
Tff nsiN PAL ter #2-7
Subdivision/Lot and/or Map and Tax Lot
To conform with the 2011 Oregon Residential Specialty Code (ORSC), Section
R318.2, I am notifying the building official that I am aware of the moisture content
requirement of ORSC Section R318.2 and have taken steps to meet this code
requirement. [Section R318.2 is provided for reference.]
Section R318.2 Moisture content. Prior to issuance of the insulation/vapor barrier
approval required by R109.1.5.2 of this code:
(A) All moisture-sensitive wood framing members used in construction shall have a moisture content
of not more than 19 percent of the weight of dry wood framing members.
(B)The general contractor or the owner who was issued the structural permit shall notify the building
official on a division approved form that the contractor or the owner who was issued the structural
permit is aware of and has taken steps to meet the requirement in paragraph (A).
Print Name: Scc3wc DA--J
Signature L \ - Date 1/4(19
T:\Building forms
or,iui —
, SPRINGFIELD
$WILDING EUGENE
LANE
COUNTY DEPARTMENT, LLC
OREGON -Exterior Wall Envelope
Self-Certification Form
I, SGovr- Pitoi , am the general contractor or the
owner-builder at the following address:
S"3G-7 .T smft- .
Street Address
SfF10 , oit- 9.747€ .
City
°u I I 50 2913 - co s-13 .
Permit#
To conform to the 2011 Oregon Residential Specialty Code (ORSC), Section
R703.1.1, I am notifying the building official that I am aware of the exterior wall
envelope requirements of R703.1.1, and hereby certify that the components of
the exterior wall envelope have been installed in accordance with the code
requirements. [Section R703.1.1 is provided for reference on the reverse side of
this form.]
arc- Dn.-) .
Print Name
I _
Ide .
Signatu
(-IN(' .
' "' Date
Revised: 2/8/2010
• Excerpt from 2011 Oregon Residential Specialty Code Section R703, Exterior Covering:
R703.1.1 Exterior Wall Envelope. To promote building durability,the exterior wall envelope shall
be installed in a manner that water that enters the assembly can drain to the exterior.The envelope
shall consist of an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8
inch space between the water-resistive barrier and the exterior veneer, and integrated flashings as
required in R703.8.The required space shall be formed by the use of any non-corrodible furring
strip, drainage mat or drainage board.The envelope shall provide proper integration of flashings
with the water-resistive barrier,the space provided and the exterior veneer.These components,in
conjunction,shall provide a means of draining water that enters the assembly to the exterior.
Exceptions: ••
1. A space is not required where the exterior veneer is installed over a water-resistive barrier
complying with section R703.2 which is manufactured in a manner to enhance drainage and
meets the 75%drainage efficiency requirement of ASTM E2273 or other recognized .
national standards.
2. A space is not required where window sills are equipped with pan flashings which drain to
the exterior surface of the veneer in a through wall fashion.All pan flashings shall be
detailed within the construction documents and shall be of either a self-adhering
membrane complying with AAMA 711-07 or of an approved corrosion-resistant material or
a combination thereof.Self-adhering membranes extending to the exterior surface of the •
veneer shall be concealed with trims or other measures to protect from sunlight.
3. A space is not required where the exterior veneer is manufactured in a manner to enhance
drainage and meets the 75%drainage efficiency requirements of ASTM E2273 or other
recognized national standards and is installed over a water resistive barrier complying with
section R703.2.
4. A space is not required where the exterior veneer is matching an existing exterior finish as '
in additions, alterations,or repairs.
5. A water-resistant exterior wall envelope shall not be required over concrete or masonry
walls designed in accordance with Chapter 6 and flashed according to section R703.7 or
R703.8. - - •
6. Compliance with the requirements for a means of drainage, and the requirements of
Section R703.2 and Section R703.8, shall not be required for an exterior wall envelope that
has been demonstrated to resist wind-driven rain through testing of the exterior wall
envelope, including joints, penetrations and intersections with dissimilar materials,in
accordance with ASTM E 331 under the following conditions:
6.1. Exterior wall envelope test assemblies shall include at least one opening, one control
joint, one wall/eave interface and one wall sill.All tested openings and penetrations
shall be representative of the intended end-use configuration.
6.2. Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size.
6.3. Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24
pounds per square foot.
6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure
duration of 2 hours. •
The exterior wall envelope design shall be considered to resist wind-driven rain where the
results of the testing indicate that water did not penetrate: control joints in the exterior
wall envelope;joints at the perimeter of openings penetration; or intersections of
terminations with dissimilar materials.