HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2013-7-1 3fl.5;-- FEIto - 5,%2/77 _ &t251 Page 1 of 1 TFs[/McanysPECnOn,.,r. Report of Inspection Services n.e,.chnicol&Construction Service Geotechnioal&Construction Services Welding/High-Strength Bolting Client: Ms. Laura Farthing Project: Hayden Bridge Water Date: 07-01-13 EWEB Intake Improvements Project No. 2127278 PO Box 10148 Springfield, Oregon Report No.: E-34332 Eugene, Oregon 97440 Inspector: C. Walpole ID No.: 01040131 AWS CWI Inspection of: Welding Shop: Eft Field: ❑ Fabricator or Erector: Double A Weather: Inside Contractor: John Hyland Construction BP No.: -- Performed continuous visual inspection of complete penetration welds and multiple pass fillet welds larger than 5/16". Inspected fit-up and monitored amps, volts and travel speed by one (1) certified welder: Welding was completed on the pipe guard 7A. Completed welds were checked for size, length, profile and location. Welding is pending FOR approval (ref: FEI report E-34295, dated 06-28-13). Dave (Double A) was asked to notify our office when additional services are needed. To the best of our knowledge, the work checked is in conformance with shop drawings revision 3 dated 05-17-13 and applicable AWS D1.1 code, except if noted above. Reviewed By: Michael L. Meye Technical Manager c: EWEB — Mike Stickling (email) John Hyland Construction—Dave Shaw (email) OBEC — Pete Slocum (email) City of Springfield • MLM:sn This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such,information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing&Inspection,Inc.'s written authorization. 750 NW Cornell Avenue•Corvallis,Oregon 97330•phone(541)757-4698 fax(541)757-2991 29540 B Airport Road•Eugene,Oregon 97402•phone(541)684-3849 fax(541)684-3851 62979 NE Plateau Drive,Suite 3•Bend,Oregon 97701 •phone(541)382-4844•fax(541)382-4846 • 399x' -G,4 FEI ze, _e725-g/ Page 1 of 1 TfST/N6blNSFfCTION,mr Report of Inspection Services °eaied^^'ro18ConiM1oo0on5ar"°° Geotechnical&Calstnidionservices Welding/High-Strength Bolting Client: Ms. Laura Farthing Project: Hayden Bridge Water Date: 06-28-13 EWEB Intake Improvements Project No. 2127278 PO Box 10148 Springfield, Oregon Report No.: E-34295 Eugene, Oregon 97440 Inspector: A. Wilson ID No.: 09020961 AWS CWI Inspection of: Welding • Shop: M Field: ❑ Fabricator or Erector: Double A Weather: •Inside Contractor: John Hyland Construction BP No.: -- Performed continuous visual inspection on complete joint penetration welds for pipe guard 7A. Welding was performed in accordance to Double A Metal's weld procedure specification DAM-FCAW-A53-PIPE. Inspected fit-up and root passes. Monitored amps, volts and travel speed by one (1)certified welder using the SMAW process E6010 electrode and the FCAW process E71T-1 electrode. Welding was still in progress at the end of today's shift. Note: welder is only qualified for welding on pipe equal to or greater than 24" in diameter with backing, backgouging or both. Work was performed on 6" diameter pipe with no backing. FOR approval is needed for welding performed to date. To the best of our knowledge, the work in-progress is in conformance with the shop drawings revision 3 dated 05-17-13 and applicable AWS D1.1 code, except if noted above. • Reviewed By: Michael L. M er Technical Manager c: EWEB— Mike Stickling (email) John Hyland Construction—Dave Shaw(email) OBEC — Pete Slocum (email) City of Springfield MLM:sn • This report and/or enclosed test data is the confidential properly of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such,information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing&Inspection, Inc.'s written authorization. 750 NW Comell Avenue•Corvallis,Oregon 97330 phone(541)757-4698.fax(541)757-2991 29540 B Airport Road•Eugene,Oregon 97402.phone(541)684-3849.fax(541)684-3851 • 62979 NE Plateau Drive,Suite 3 Bend,Oregon 97701 phone(541)382-4844•fax(541)382-4846 3`qq5- Page 1 of 1 FEI [EST/NGSINSPECTION,,.,r Report of Inspection Services Geo,echekol6CamrrodlonService Geotechnical&Construdion Services Welding/High-Strength Bolting Client: Ms. Laura Farthing Project: Hayden Bridge Water Date: 06-26-13 EWEB Intake Improvements Project No. 2127278 - PO Box 10148 Springfield, Oregon Report No.: E-34262 Eugene, Oregon 97440 Inspector: A. Wilson ID No.: 09020961 AWS CWI Inspection of: Welding Shop: ® Field: ❑ Fabricator or Erector: Double A Weather: Inside Contractor: John Hyland Construction BP No.: -- Performed continuous visual inspection of partial penetration groove welds and multiple pass fillet welds larger than 5/16" during the fabrication of slip-not cover assembly 10A. Inspected fit-up and monitored amps, volts and travel speed by one (1) certified welder using the GMAW process E7OC-6M electrode. Completed welds were checked for size, length, profile and location. Chris (Double A Metal)was asked to notify our office when additional services are needed. To the best of our knowledge, the work checked is in conformance with shop drawings dated 05-20-13 and applicable AWS D1.1 code, except if noted above. ■ Reviewed By: Michael L. M er Technical Manager • c: EWEB — Mike Stickling (email) John Hyland Construction —Dave Shaw(email) OBEC — Pete Slocum (email) City of Springfield MLM:sn This report and/or enclosed test data is the confidential properly of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such,information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing&Inspection. Inc.'s written authorization. 750 NW Comell Avenue•Corvallis,Oregon 97330•phone(541)757-4698•fax(541)757-2991 29540 B Airport Road Eugene,Oregon 97402•phone(541)684-3849•fax(541)684-3851 62979 NE Plateau Drive,Suite 3•Bend,Oregon 97701 •phone(541)382-4844 fax(541)382-4846 • - Yefz , Page 1of1 FE' Report of Inspection Services TfSTINGSINSPET/ONAL G'o,erhn;caiacon, °=^s"" Geotechnical&Construdion Services Welding/Hiqh-Strength Bolting Client: Ms. Laura Farthing Project: Hayden Bridge Water Date: 06-25-13 EWEB Intake Improvements Project No. 2127278 PO Box 10148 Springfield, Oregon Report No.: E-34245 Eugene, Oregon 97440 Inspector: A. Wilson ID No.: 09020961 AWS CWI Inspection of: Welding Shop: Field: ❑ Fabricator or Erector: Double A Weather: Inside Contractor: John Hyland Construction BP No.: -- Performed continuous visual inspection on complete penetration welds during in-progress welding of slip- not cover assembly 10A. Inspected back gouge and monitored amps, volts and travel speed by one (1) certified welder using the GMAW process E7OC-6M electrode. Completed welds were checked for size, length, profile and location. To the best of our knowledge, the work in-progress is in conformance with the shop drawings dated 05- 20-13 and applicable AWS D1.1 code, except if noted above. Reviewed By: Mgt/ Michael L. M r Technical Manager c: EWEB— Mike Stickling (email) John Hyland Construction — Dave Shaw(email) OBEC — Pete Slocum (email) City of Springfield MLM:sn • This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated..As such,information contained herein shalt not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing 8 Inspection, Inc.'s written authorization. 750 NW Cornell Avenue•Corvallis,Oregon 97330 phone(541)757-4698 fax(541)757-2991 29540 B Airport Road•Eugene,Oregon 97402 phone(541)684-3849'fax(541)684-3851 62979 NE Plateau Drive,Suite 3 Bend,Oregon 97701 •phone(541)382-4844 fax(541)382- 846 3'MT � On Page 1 of 1 FE' TfSDNG6/NSPECl/ON,ixr. Report of Inspection Services cemeahnloola eemM1Vcuon Sarin" Geotechnical&consm.djon services Weldinq/Hiqh-Strength Bolting Client: Ms. Laura Farthing Project: Hayden Bridge Water Date: 06-24-13 EWEB Intake Improvements Project No. 2127278 PO Box 10148 Springfield, Oregon Report No.: E-34234 Eugene, Oregon 97440 Inspector: A. Wilson ID No.: 09020961 AWS CWI Inspection of: Welding Shop: 10. Field: ❑ Fabricator or Erector: Double A Weather: Inside • Contractor: John Hyland Construction BP No.: -- Performed continuous visual inspection on complete joint penetration welds during the fabrication of structural steel slip-nut cover assembly 10A. Inspected fit-up and monitored amps, volts and travel speed by one (1) certified welder using the GMAW process E70C-6M electrode. At end of shift, welding was still in-progress. To the best of our knowledge, the work in-progress is in conformance with shop drawings dated 05-20-13 and applicable AWS D1.1 code, except if noted above. • Reviewed By: • Michael L. Meyer Technical Manager • • c: EWEB — Mike Stickling (email) • • John Hyland Construction—Dave Shaw(email) OBEC — Pete Slocum (email) City of Springfield MLM:sn • This report and/or enclosed test data is the confidential properly of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing&Inspection, Inc.'s written authorization. 750 NW Cornell Avenue•Corvallis,Oregon 97330•phone(541)757.4698•fax(541)757-2991 29540 B Airport Road•Eugene,Oregon 97402 phone(541)684-3849•fax(541)684-3851 62979 NE Plateau Drive,Suite 3•Bend,Oregon 97701 •phone(541)382-4844•fax(541)382-4846 IfSTINCsINFEI SGfCIION,INr. viQZ9/3- .012 Compressive Strength of Concrete Geotetbni,nl n Conu,udicn Services Geotechniral&Corlstrudtion Seniioes (ASTM C 39) CLIENT Ms. Laura Farthing PROJECT Hayden Bridge Water DATE 06-21-13 EWEB Intake Improvements PROJECT NO. 2127278 PO Box 10148 Springfield, Oregon REPORT NO. 8832 Eugene, Oregon 97440 BP NO. -- DATE CAST 06-14-13 CAST BY D. Delatte DATE RECEIVED 06-15-13 STRENGTH REQUIRED 4000 psi SPECIMEN SIZE 4"x 8" STRENGTH PLACED 4000 psi SACKS SUPPLIER Knife River PRODUCT CODE 45K170L0 CEMENT -- MAX SIZE AGG. 3/4" ADDITIVES AEA,Tetra AIR CONTENT 3.6% LOAD NO. 1 TICKET NO. 3976283 SLUMP 3 1/2" CONCRETE TEMP 69°F YARDAGE 5.0 OF 5.0 TIME 6:05 AM AIR TEMP 49° F WEATHER Overcast SPECIMEN STORAGE ASTM C 31 POUR LOCATION Intake pipe mounting plate. AVERAGE TEST AGE AREA WEIGHT • TOTAL COMPRESSIVE STRENGTH TIME OF TYPE OF DATE (DAYS) (IN.2) (LBS) LOAD(LBS) STRENGTH(PSI) (PSI) TEST FRACTURE" 06-21-13 7 12.56 8.60 74430 5930 8:40 AM 2 07-12-13 28 07-12-13 28 Hold —.1-End Cones 2-Cone/Split 3-Columnar 4—Diagonal 5—Side(top or bottom) 6—Side(pointed top or bottom) REMARKS: Dave (JHC)was advised of on-site test results. Reviewed By: / � • Michael L. Mayo Technical Manager c: EWEB- Mike Stickling (email) John Hyland Construction-Dave Shaw(email) OBEC- Pete Slocum(email) City of Springfield MLM:sn This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such,information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing&Inspection,Inc.'s written authorization. 750 NW Cornell Avenue•Corvallis,Oregon 97330 phone(541)757-4698•fax(541)757-2991 29540 B Airport Road•Eugene,Oregon 97402 phone(541)684-3849'fax(541)684-3851 62979 NE Plateau Drive,Suite 3 Bend,Oregon 97701 phone(541)382-4844 fax(541)382 1846