Loading...
HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2013-5-14 (3) Professional Service Industries,Inc. 1--!� ° Infot7nation 6032 N.Cutter Circle,Suite 480 �-L..�./V7 Portland,OR 97217 U `220 .To Build On CCP No.176269 Phone:(503)289-1778 l /2_ _370 Engineering • Consulting • Testing Fax:(503)289-1918 ✓ Report No: CON:06541N Concrete Test Report Isssue sue No: 2 Client: WAL-MART STORES, INC. CC: BLAKE JOHNSON These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations.This report may not be 2001 S E 10TH ST, MAIL STOP BOB GARRISON reproduced,except In full.without written permission by Professional Service 5570 CAITLIN NUGENT Industries,Inc.Ira non-compliance appears on this report,to the extent mat the reposed noncompliance impacts the project,the resolution is outside the BENTONVILLE, AR 72716-5570 DAVID NICHOLS PSI scope or engagement. ERIC EVENSON Project: WM 4178-00 SPRINGFIELD OR TO KATYRYNRYN JER JERKOVICH SPRINGFIELD, OR ROBERT CASTILE WILSON HU Approved Signatory:Deborah Priest(Special Project Manager) Date of Issue: 6/12/2013 Mix Data Supplier - Knife River Plant Knife River Prestress Mix Identification 247RNE7E00 Specified Design Strength(psi) 4000 at age 28 days Details of Sample Date Sampled 5/14/2013 Date Received 5/16/2013 Measured Specified Slump(in) ASTM c 143 5.00 General Location Stem walls A at 2.6-3.5 and Ftg.G-G.5 at 1.8-3.1 Slump w/plasticizer(in) N/A Sample Location Same as General Location Air Temp(°F) 87 Curing Method One day Field/Laboratory Cure Concrete Temp(°F) 'ASTM C 1064 77 Field Sample No Field Cure Temp(°F) High Air Content(%) ASTM e 231 4.50 Low Unit Weight(pcf) ASTM C 138 Contractor SD Deacon Batch Size(yd') 10.5 Truck No. 695 Ticket No. 3975560 Water Added(gal) Before 5 Sampled By Glenn Meek After Submitted By Glenn Meek Time Batched 12:46 Weather Clear • Time Sampled 13:48 Est.Wind (mph) NA Yd'Placed 10.5 Time,Placed 14:30 Est. Rh (%) 0 Time In Truck(mins) 104 Compressive Strength of Concrete Cylinders ASTM C 39 Specimen ID Date Tested Age Dimensions(in) Area(in') Type of Ultimate Fracture Compressive Required (Days) Diameter Height Cap Load(lbf) Type/Remark Strength(psi) Strength(psi) 0654137-34-C1\1 05/21/13 7 4.01 8.01 12.63 U 51190 2 4050 0654137-34-C1\2 06/11/13 28 4.01 8.02 12.63 U 79200 3 6270 4000 0654137-34-C1\3 06/11/13 28 4.01 8.02 12.63 U 85990 3 6810 4000 0654137-34-C1\4 06/11/13 28 4.01 8.02 12.63 U 85150 3 6740 4000 0654137-34-C1\5 07/09/13 56 U 4000 Average 28 Day Compressive Strength(psi) 6610 Notes Remarks 1.Sampting to ASTM C 172 Fracture Type/Remarks:2=C39:Vert crack/cone opposite end:C1314:Cone&Shear.3= 2.Speclmen(s)Prepared to ASTM C 31 C39:Ven cracking/no cones:C1314:Cone 8 Split, 3.Capping B=Bonded ASTM C 617,U=Unbonded ASTM C 1231,c=Combined Applicable ASTM standards unless otherwise indicated: Slump: C143. Form No: 18970,Report No:CON:0654137-34-CI 6)2000-2011 OESTLab by SpecfraOESTcom Page 1 of 1