HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2013-6-4 (4) c,c o Information 5 ( 2_ 7o &II .To Build On Engineering•Consulting• Testing DAILY OBSERVATION REPORT OF SINGLE-PLY THERMOPLASTIC ROOFING Date: 6/4/13 PROJECT INFORMATION Client: Wal-Mart Stores, Inc. (Store#4178) Work Area: Various Areas Project Name: Roofing Project Manufacturer: Johns Manville 60 mil reinforced TPO Location: Springfield, OR Insulation Type: JM Energy 3 Isocyanurate PSI Report No.: 654137-101-16 Contractor: Central Oregon Roofing PSI Hours Worked: 12.0 Approximate Contractor Hours Worked: 12.0 SIGNATURES Sam Stoner Isaac Doug Roth, RRO PSI Quality Assurance Observer Roofing Contractor Reviewed By: Representative PSI Project Manager PROJECT STATUS AT-A-GLANCE Today's Performance Comment Construction today? ®Yes ❑ No If No Construction, Inspection Done? ❑Yes ❑ No Contractor performance issues? ❑Yes ® No Schedule/scope issues? ❑Yes ® No DAILY PRODUCTION Total Square Feet Completed To Date Previously Today's Total Square Total Square Roof Section Completed Square Feet Feet Feet in % Complete Square Feet Completed Completed Section Main Roof Area 38,544 505 39,049 39,049 100 39,049 39,049 100 Crew Size—4 Roofers—4 Sheet Metal Workers—0 Page 1 of 4 PSI Project No:654137 Date: 6-4-13 WEATHER CONDITIONS & EMERGENCY COVER ® Dry ® Sunny ❑ Cloudy Z Windy ❑ Rain ❑ Snow Temp Range (low-high) 46°to 76° F Emergency cover/protection on-site? ®Yes ❑No Type of Protection -TPO & EPDM membrane MATERIALS CONTROL & STORAGE In original identified packaging? ®Yes❑ No Off ground or deck? ®Yes❑ No Covered and vented? ®Yes❑ No Roll goods stored on side? ®Yes❑ No Adhesive storage temperature Unapproved, damaged, or wet maintained? ❑Yes No material? If Yes, how disposed? ❑ Yes No Comments: Stored material protection appears adequate. SUBSTRATE PREPARATION • Night tie-in removed? ®Yes ❑ No Substrate clean and debris ®Yes❑ No removed? Substrate and penetrations ready? ®Yes❑ No Substrate tested for dryness? ®Yes ❑ No Comments: Substrates that received new roofing components appeared clean and dry. • COVER BOARD APPLICATION (1" ENERGY 3) Correct Number of fasteners & Rhino Plates?(12 in corners, 9 at perimeter, ®Yes❑No Additional fasteners at ®Yes❑ No 6 in the field) perimeters and corners? Fasteners checked by technician? ®Yes❑ No Short insulation joints ® Yes❑ No staggered? New/Existing Insulation joints tight? ® Yes❑No All joints staggered between layers? ®Yes❑ No Gaps filled with spray foam? ®Yes ❑ No Drainage crickets installed per ®Yes❑ No plans and specifications? Comments: Cover board was installed on the upper roof area at G from 1.9 to 3.1. SINGLE-PLY MEMBRANE APPLICATION (60 MIL REINFORCED JOHNS MANVILLE TPO) Membrane allowed to relax prior to Yes❑ No Membrane fully welded to Rhino ❑Yes 0 No attachment? Plates? Membrane/plate welds checked by technician? Yes ❑No Membrane properly lapped? ®Yes❑ No Seams clean prior to welding? 0 Yes ❑ No Continuous weld achieved? 0 Yes ❑ No Page 2 of 4 PSI Project No:654137 Date: 6-4-13 SINGLE-PLY MEMBRANE APPLICATION (60 MIL REINFORCED JOHNS MANVILLE TPO) (CONT'D) Membrane flow at lap welds? N Yes❑No Seams probed by technician N Yes❑ No Cut edge sealant installed? ❑Yes 0 No T-patches installed? ❑Yes N No Primary field membrane termination ❑Yes N No (T-bar) installed? Comments: Not all induction welds were completed today(work in progress). BASE FLASHING APPLICATION (60 MIL REINFORCED JOHNS MANVILLE TPO) Substrate clean and prepared? ❑Yes❑ No Adhesive applied to substrate ❑Yes❑ No and allowed to dry? Adhesive applied to back of base ❑ Yes❑ No Adhesive allowed to flash off? ❑Yes❑ No flashing? Flashing pressed onto substrate to ❑Yes❑ No Flashing properly lapped onto ❑Yes❑ No promote adhesion? field membrane? Seams cleaned prior to welding? ❑Yes❑No Membrane flow at welds? ❑Yes❑ No Continuous weld achieved? ❑ Yes❑No Manufacturer's approved corner ❑ Yes❑ No patches installed? Seams probed by technician ❑Yes❑ No Cut edge sealant installed? ❑Yes❑ No Termination bars installed? ❑Yes ❑ No Countedlashings installed? ❑Yes❑ No • Comments: None installed today. NIGHT TIE-IN I DAMAGE/SITE CLEANUP INSPECTION Night seal installed? N Yes❑ No Roofing appears watertight? N Yes❑ No Roof drain flashings completed? ❑Yes N No Damage to property? ❑Yes N No Damage to client's equipment? ❑Yes N No Site broom clean? ❑ Yes N No All debris removed from roof? ❑ Yes N No Roof materials and equipment N Yes❑ No appear secured? Comments: The roof appears watertight. Page 3 of 4 PSI Project No:654137 Date: 6-4-13 DETAIL INSTALLATION (NOTE DRAWINGS USED AS REFERENCE) Detail# Detail Name Construction Summary(Quantity/Description/Comment) SUMMARY OF TODAY'S WORK/ DEVIATIONS/SPECIAL NOTES: Summary Comments: Contractor continues to methodically complete all induction welds. Field and flashing detailing is ongoing. Work completed today appeared to conform to project plans and specifications. Unresolved EVOCO Deviation Number(s): 0 Special Notes: None today. Respectfully Submitted, PROFESSIONAL SERVICE INDUSTRIES, INC. PSI Roof Observer: Sam Stoner CC: Portland, OR—One copy electronically Reviewed By: Doug Roth, RRO Page 4 of 4