SPECIAL INSPECTION REPORT Job # I3-4262-D00
SrLt.�J 1.6799 "
Date:4/25/2013 Permit # 811-2013-02250
Mail To: Project:
DLA CONSTRUCTION SERVICES,LLC . SPRINGFIELD BUFFALO WILD WING
871 CANTERBURY RD UNITG 2770 GATEWAY ST
WEST LAKE,OH 44145 SPRINGFIELD,OR 97477
JOB#12086
Field Inspection: Inspector: Jason Brown
ACS Testing arrived on site to inspect the steel deck attachment using the HILT! X-EDN 19/X-EDNK22 fastener
type for the roof deck connection per the email attached from Kim Anderson with associated consultants, for the 20
gauge steel roof decking for the patio in Lieu of the puddle welding per the schedule on S202. The I-IILTI pins
appeared to have metal to metal contact and installed per the ESR 2197. Revisions made to these plans on 1/21/2013
all revised unknown.
•
•
Our reports pertain to the material tested or inspected only. Information contained herein is not to be reproduced except in full,
without prior written authorization from this office.
Reviewed 11-d'ep Au,_ Date: 04-26-2013
BR/
JB
CC:
Brad Sisk, Kim Anderson, Robert Castile
7409 SW Tech Center Dr. Ste. 145
Tigard.OR.97223
�� �'w
Ph: 503-443-3799 Fax: 503-620-2748
/c"r"r` DAILY FIELD REPORT FOR PROPRIETARY ANCHORS
"'TESTING, INC
?1 ;. 11L$799 Date: 4/25/2013 Permit#: 811-2013-02250
SPRINGFIELD BUFFALO WILD
DLA CONSTRUCTION SERVICES, Continuous / WING
LLC 2770 GATEWAY ST
871 CANTERBURY RD UNIT G Periodic SPRINGFIELD, OR-17477
WEST LAKE, OH 44145
JOB #12086
INSPECTOR/CERT Jason Brown cert#1018 ACS Job # 13-4262-D00
Anchor Embedded in: Concrete IS THIS A REINSPECTION?: Yes ✓ No
Compressive Strength: EXISTING UNKNOWN APPROVED PLANS AVAILABLE ✓ Yes No
HOLE DETAIL/CONDITION WORK ACCEPTABLE PER
APPROVED PLANS: 0 Yes No
ANCHO 3/4„ HOLE 7/8"
EMBED 8„ Installation complies with
RSIZE: DIA. DEPTH manufacturer's evaluation report? Ill Yes No
Holes cleaned properly?: �/ Yes No
LOCATION OF ANCHORS
Embedment per plans?: v' Yes I I No
GRIDLINES Interior corner columns foot plates of the patio
ESR INSTALLATION
SR REPORT#
GRIDLINES
ESR-2322 HILTI-HIT-RE 500-SD GRIDLINES
TYPE OF ANCHOR: gLLTHREAD
IS THERE AN RFI? Yes 1✓ No
EPDXY TYPE: HIlti Hit RE 500 SD RFI ATTACHED? ❑ Yes III No
INSPECTION DETAILS:
E xp.Date: 02/2014
ACS Testing arrived on site to observe the installation of 8 3/4"all
thread anchors using 4 per baseplate at an embedment of 8 inches per
detail 6/S301 of the approved plans. The cleaning procedure and
installation appears to be in conformance with ESR 2322 and the
approved plans. Revisions made to these plans on 1/21/2013 all
revised unknown.
Foreman notified of Yes I I No 0 NA
nonconformance items?
Foremans Name:
Reviewed
(?-0\0� (13/\ Date: cC:
04-26-2013 Brad Sisk,Kim Anderson, Robert Castile
•