Loading...
HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2013-4-25 • ACS Testing Inc 7409 SW Tech Center Dr., Suite 145 Tigard,OR 97223 Phone:503-443-3799 Pas:503-620-2748 SPECIAL INSPECTION REPORT Job # I3-4262-D00 SrLt.�J 1.6799 " Date:4/25/2013 Permit # 811-2013-02250 Mail To: Project: DLA CONSTRUCTION SERVICES,LLC . SPRINGFIELD BUFFALO WILD WING 871 CANTERBURY RD UNITG 2770 GATEWAY ST WEST LAKE,OH 44145 SPRINGFIELD,OR 97477 JOB#12086 Field Inspection: Inspector: Jason Brown ACS Testing arrived on site to inspect the steel deck attachment using the HILT! X-EDN 19/X-EDNK22 fastener type for the roof deck connection per the email attached from Kim Anderson with associated consultants, for the 20 gauge steel roof decking for the patio in Lieu of the puddle welding per the schedule on S202. The I-IILTI pins appeared to have metal to metal contact and installed per the ESR 2197. Revisions made to these plans on 1/21/2013 all revised unknown. • • Our reports pertain to the material tested or inspected only. Information contained herein is not to be reproduced except in full, without prior written authorization from this office. Reviewed 11-d'ep Au,_ Date: 04-26-2013 BR/ JB CC: Brad Sisk, Kim Anderson, Robert Castile 7409 SW Tech Center Dr. Ste. 145 Tigard.OR.97223 �� �'w Ph: 503-443-3799 Fax: 503-620-2748 /c"r"r` DAILY FIELD REPORT FOR PROPRIETARY ANCHORS "'TESTING, INC ?1 ;. 11L$799 Date: 4/25/2013 Permit#: 811-2013-02250 SPRINGFIELD BUFFALO WILD DLA CONSTRUCTION SERVICES, Continuous / WING LLC 2770 GATEWAY ST 871 CANTERBURY RD UNIT G Periodic SPRINGFIELD, OR-17477 WEST LAKE, OH 44145 JOB #12086 INSPECTOR/CERT Jason Brown cert#1018 ACS Job # 13-4262-D00 Anchor Embedded in: Concrete IS THIS A REINSPECTION?: Yes ✓ No Compressive Strength: EXISTING UNKNOWN APPROVED PLANS AVAILABLE ✓ Yes No HOLE DETAIL/CONDITION WORK ACCEPTABLE PER APPROVED PLANS: 0 Yes No ANCHO 3/4„ HOLE 7/8" EMBED 8„ Installation complies with RSIZE: DIA. DEPTH manufacturer's evaluation report? Ill Yes No Holes cleaned properly?: �/ Yes No LOCATION OF ANCHORS Embedment per plans?: v' Yes I I No GRIDLINES Interior corner columns foot plates of the patio ESR INSTALLATION SR REPORT# GRIDLINES ESR-2322 HILTI-HIT-RE 500-SD GRIDLINES TYPE OF ANCHOR: gLLTHREAD IS THERE AN RFI? Yes 1✓ No EPDXY TYPE: HIlti Hit RE 500 SD RFI ATTACHED? ❑ Yes III No INSPECTION DETAILS: E xp.Date: 02/2014 ACS Testing arrived on site to observe the installation of 8 3/4"all thread anchors using 4 per baseplate at an embedment of 8 inches per detail 6/S301 of the approved plans. The cleaning procedure and installation appears to be in conformance with ESR 2322 and the approved plans. Revisions made to these plans on 1/21/2013 all revised unknown. Foreman notified of Yes I I No 0 NA nonconformance items? Foremans Name: Reviewed (?-0\0� (13/\ Date: cC: 04-26-2013 Brad Sisk,Kim Anderson, Robert Castile • Bob Brown, President BB/JB S • errornitrn