HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2013-5-28 (3) Professional Service Industries,Inc.
i fir 1, D 7 Information 6032 N.Cutter Circle.Suite 480
, '+�—��1^^77 Portland,OR 97217
Il �/L.! CCB No.176269
L� ll7 Build On Phone:(503)289-1778 (S (2_ ^1- -7�
Engineering •• Consulting•• Testing Fax:(503)289-1918 [
Report No: FC:06
Concrete Field Report
Isssue sue No: 1
Client: WAL-MART STORES, INC. CC: BLAKE JOHNSON These test results apply only to the speurc locations and materials nosed and
may not represent any other locations or elevations.This report may not be
2001 S E 10TH ST, MAIL STOP BOB GARRISON reproduced,except in full,without wntten permission by Professional Service
5570 CAITLIN NUGENT Industries,Inc.If a non-compliance appears on this report,to the extent that
the reported non-compliance impacts the project,the resolution is outside the
BENTONVILLE, AR 72716-5570 DAVID NICHOLS PSI scope of engagement.
ERIC EVENSON
Project: WM 4178-00 SPRINGFIELD OR TO KATYRYN JERKOVICH
SPRINGFIELD, OR ROBERT CASTILE —x
WILSON HU Approved Signatory:Deborah Priest(Special Protect Manager) •
Date of Issue: 5/30/2013
General Field Data
Technician: Glenn Meek
Test Date: 5/28/2013 .
Weather: Mild
Test Results
Set No. Specimens Ticket Time Time Cubic Yards Slump(in) Air Content Air Temp. Concrete
Made Batched Unloaded Placed (%) (5F) Temp. (°F)
0654137-70-C1 4 NA i l — �_ ___ __._,_ _ - _ 57 , 66 ._ _
0654137-70-C2 4 3975858 I 11:43 i 12:45 I 4.0 i 10.00_x- _-- -- -- 57 i 67
Location & Remarks
General Location: Truck screen 8"cmu wall A at 2.6-4.8 12th-21st course
Set No. Location Remarks
0654137-70-C1 Truck screen 8"cmu wall A at 2.6-3.5 12th-15th course 1
General Location: Truck screen 8"cmu wall A'a-12.6-4.8 12th-18th course
Set No. Location Remarks
0654137-70-C2 ,Same as General Location i
Mix Data
Set No. Supplier Mix Design Strength(psi)
0654137-70-C1 Site Mix Type S Mortar TYPE _ '2000
0654137-70-02 Knife River I 2420G3K500 ;2000
•
Notes Remarks
Sampled from Revolving Drum Truck Miser(ASTM C 172.5.2.3) Applicable ASTM standards unless otherwise indicated: Making
Samples: C31 (except sec. 10.1.2); Slump: C143;Air Content: C231
(except sec.6);Temperature: C1064;Sampling: 0172; Grout: C1019;
Slump-Flow: C1611; Mortar: C109; Flow: C1437.
Form No:18971,Report No:FC:0654137-70 ®2000-2011 OESTLab by SpectraOEST.com Page 1 of 1