HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2013-5-1 •
Professional Service Industries.Inc.
Cri° Inf ormation Porl nd,Cutter
97ircle,Suite 480
Po32 N. OR 97217 C ^�
To Build On Phone:(503)289-1778 S 12 ` ci-a 7 V
Engineering• Consulting • Testing Fax:(503)289-1918
Concrete Field Report Report No: FC:06No: 1
Isssue sue No: 1
. Client: WAL-MART STORES, INC. CC: BLAKE JOHNSON These test results apply only to the specific locations and materials noted and
may not represent any other locations or elevations.This report may not be
2001 S E 10TH ST, MAIL STOP DAVID NICHOLS reproduced,except in full,without written permission by Professional Service
5570 ERIC EVENSON Industries,Inc.If a non-compliance appears on this report,to the extent that
the reported non-compliance impacts the project,the resolution is outside the
BENTONVILLE, AR 72716-5570 KATYRYN JERKOVICH PSI scope of engagement.
ROBERT CASTILE
' Project: WM 4178-00 SPRINGFIELD OR TO WILSON HU
SPRINGFIELD, OR
Approved Signatory.Deborah Priest(Special Protect Manager)
Date of Issue: 5/15/2013
General Field Data
Technician: Glenn Meek
Test Date: 5/1/2013
Weather: Sunny
Test Results
Set No. Specimens Ticket Time Time Cubic Yards Slump(in) Air Content Air Temp. Concrete
Made Batched Unloaded Placed (%) (°F) Temp, (°F)
0654137-16-C1 0 3798011 t 05:28 06:35 I ___ I ___5.00_ _ 1.70 '_ _ _46_ _ 57
0654137-16-C2 5 3798013 06:08 07:30 -- 4.00 -__ 1.80 46 — 61 __
0654137-16-C3 0 3798018 i 08:07 1 09:15 i t 5.00 1.40 55 57
Location & Remarks
General Location: SOG B-B.5/3.1-4,A-F.5/1.2-1.8
__ - ..___ __.___.___—_.__. __ - __ _ - - -- - -
Set No. Location Remarks
0654137-16-C1 'SOG slump and air only __ __ __ ___ __ ___ __ ____ _ _ __ ___ _
0654137-16-C2 Same as General Location
0654137-16-C3 .Same as General Location . I
Mix Data
Set No. Supplier __ _________Mix _ _ Design Strength(psi)
0654137-16-C1 Knife River 7RNE5300 3500
0654137-16-C2 'Knife River _ 7RNE5300 .3500
0654137-16-C3 Knife River ,7RNE5300 '3500
•
Notes Remarks
Sampled from Revolving Drum Truck Mixer(ASTM C 172.5.2.3) , Applicable ASTM standards unless otherwise indicated: Making
Samples: C31 (except sec. 10.1.2); Slump: C143;Air Content: C231
(except sec.6);Temperature: C1064:Sampling: C172;Grout: C1019:
Slump-Flow: C1611; Mortar: C109; Flow: C1437.
Form No:18971,Report No:FC:0654137-16 C)2000-2011 OESTLab by SpectraOEST com Page 1 of 1