Loading...
HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2013-6-4 Professional Service Industries.Inc. � IIZf OY/YlLlllOi� Portland,N.,OR Circle,Suite 480 tj](/�/'��J J i Build yr Portland,OR 97217 S r-/ u 10✓ut4U On Phone:(503)289-1778 J 1.2_ ^�� 70 Engineering • Consulting • Testing Fax' 289-1918 Concrete Field Report Report No: FC:06s eNo: 1 Issue No: 1 Client: WAL-MART STORES, INC. CC: BLAKE JOHNSON These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations.This report may not be 2001 S E 10TH ST, MAIL STOP BOB GARRISON reproduced,except in full,without written permission by Professional Service 5570 CAITLIN NUGENT industries,Inc.If a non-compliance appears on this report.to the extent that the reported non-compliance impacts the project,the resolution is outside the BENTONVILLE, AR 72716-5570 DAVID NICHOLS PSi scope of engagement. ERIC EVENSON Project: WM 4178-00 SPRINGFIELD OR TO KATYRYN JERKOVICH SPRINGFIELD, OR ROBERT CASTILE WILSON HU Approved Signatory:Deborah Priest(Special Project Manager) Date of Issue: 6/12/2013 General Field Data Technician: Dale Russell Test Date: 6/4/2013 Weather: Clear Test Results Set No. Specimens Ticket Time Time Cubic Slump(in) Air Content Air Temp. Concrete Unit Weight Made Batched Unloaded Yards (%) (°F) Temp.(°F) (lb/ft') Placed 0654137-95-C1 4 Site Batched 09:00 _' 09:10 1.0 66 l 77 0654137-95-C2 5 3978341 08:55 I 09:10 10.8 1 4.00 1.20 69 1 72 1 14a3 Location & Remarks General Location: Knee walls and columns East of gridline G Set No. Location Remarks Mixed on site by Haps Masonry Approved Mortar: SPEC MIX,Type S mixed per manufacturers 0654137-95-C1 Veneer for knee walls and columns at grids 1 to 1.5 recommendations,meeting ASTM C 270/C 1714 requirements. With 1-1.5 oz of Tamms AKKRD-7T,polymer adhesive added per 80#bag. General Location: Store front entrance Set No. Location Remarks Vestibule, East of gridline G from 1.8 to 3.1,miscellaneous S.O.G.repairs at gridlines B.2/4.8-5,a 4"raised S.O.G in the 0654137-95-C2 electrical room at approx grids A/1.1-1.5 and approximately 3 Mix ID#081-7RNE5300,This is a non air entrained mix. yds were placed as concrete bedding around the grease interceptor per detail 8 of Sheet P2. l Mix Data Set No. Supplier _ _ J_ Mix _ Design Strength(psi) 0654137-95-C1 'i :2000 0654137-95-C2 Knife River 1081-35CE4C00 ,3500 Notes Remarks Sampled from Stationary Mixer(ASTM C 172.52.1) Sampled from Revolving Drum Truck Mixer(ASTM C 172.5.2.3) Form No:18971,Report No:FC:0654137-95 ®20002011 OESTLab by Specfra0ESTcom Page 1 of 1