Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Specifications 2013-6-
CertainTeed El Builders Statement InsulSafe® SP Fiber Glass Blowing Insulation c.), 1 �e,4-rrr,LA Homeowner Name/Jobsite Name L/ 735 Unica1 T n'ace Home A ress I Sfiiiii Mint ii a 10 0 5-0,3-c70/3 Installer/Contra for (sign) Company Name Date Builder(sign) Company Name Date Inspected By(sign if required) Date OPEN ATTIC APPLICATION MINIMUM MAXIMUM NET S0.FT. MINIMUM WEIGHT- MINIMUM MINIMUM R-VALUE BAGS PER 1000 S0.FT. PER BAG COVERAGE POUNDS PER S0.FT. INSTALLED THICKNESS SETTLED THICKNESS To obtain a Bags per Contents of bag Weight per sq.ft.of Installed insulation Minimum settled insulation thermal resistance 1000 sq.ft. shall not cover installed insulation shall shall not be less than: shall not be less than: (R)of: of net area: more than:(sq.ft.) not be less than:(lbs.) (in.) (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 _ 18.50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8.75 8.75 19 9.3 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 5.25 11 5.3 190.5 0.163 4.50 4.50 R-VALUE THICKNESS NET AREA(50.FT.) INSULSAFE SP ✓) BAGS USED BATTS/ROLLS(✓) CEILINGS -- R J V /'/ S b 54`5 /7 WALLS FLOORS THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION • In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft of net area for each R-Value listed. • The maximum net coverage must not exceed that specified for each R-Value. • The insulation must be installed at or above the specified installed thickness for each R-Value. • Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in reduced R-Value. • This product should not be mixed with other blown insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES.THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. i 02007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Builders Statement 2/07 I . /- Manufacturer Insulation Fact Sheet CertainTeed El This is CertainTeed Corporation InsuISafe® SP Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insula- tion is installed with pneumatic equipment in a horizontal open blow application. MINIMUM MAXIMUM NET SO.FT. MINIMUM WEIGHT- MINIMUM MINIMUM R-VALUE BAGS PER 1000 SO.FT. PER BAG COVERAGE POUNDS PER SO.FT. INSTALLED THICKNESS SETTLED THICKNESS To obtain a Bags per Contents of bag Weight per sq.ft.of Installed insulation Minimum settled insulation thermal resistance 1000 sq.ft. shall not cover installed insulation shall shall not be less than: shall not be less than: (R)of: of net area: more than:(sq.ft.) not be less than:(lbs.) (in.) (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 • 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8.75 8.75 19 9.3 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 - 5.25 R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic Application. Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x 4-inch diameter internally corrugated blowing hose. COVERAGE CHART-CLOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATIONS The following thermal performances are achieved at the thicknesses, weights and coverages specified when insula- tion is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m3. REQUIRED OR MINIMUM MAXIMUM NET SO.FT. MINIMUM WEIGHT- INSTALLED R-VALUE BAGS PER 1000 SO.FT. PER BAG COVERAGE POUNDS PER 5O.FT. THICKNESS To obtain a Bags per Contents of bag Weight per sq.ft.of Installed insulation thermal resistance 1000 sq.X. shall not cover installed insulation shall shall not be less than: (R)of: of net area: more than:(sq.ft.) not be less than:(lbs.) (in.) 29 31.2 32.1 0.967 7.25 22 23.7 42.3 0.733 5.50 16 17.2 58.1 0.533 4.00 15 16.1 62.0 0.500 3.75 14 15.1 66.4 0.467 3.50 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly. ©2007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Manufacturer Fact Insulation Sheet 2/07