HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2013-4- Page 1 of 1
6,re
WING
l
Geotechnica &ConstmcanSer�ces Daily Field Report
IN6&INSPE(iION�INC: y p
Client: Ms. Connie Speck Project: Giustina Resources Office Bldg. Date: 04-09-13
Giustina Resources 200 International Way Project No.: 2137002
PO Box 529 Springfield, Oregon Report No.:, E-33611
Eugene, Oregon 97440 Inspector: D. Delatte
ID No.: 1080867-88
ICC
Inspection of: Reinforced Concrete Weather: Overcast Continuous Inspection: ❑
Contractor: Chambers Construction Co. BP No.: 811-SPR2012-02519 Periodic Inspection: l?
Performed inspection on the reinforcing steel for slab on grade with thickened areas,
line A to G, from 2.5 to 6, line B.2 to C, from 2 to 2.5 and line A.1 to A.5, from 0.5 to 1.
Reinforcing steel was checked for grade, size, lap, placement, quantities and
clearance. Reinforcing steel was lifted up off grade during concrete placement.
Observed the placement of 122.0 yards of Eugene Sand and Gravel 4500 psi(4000 psi
required) concrete (mix 314568) for slab noted above. Concrete was placed by pump
and was mechanically consolidated. Cast two (2) sets of four(4) 4" x 8" concrete test
cylinders.
Set 1 —Load 3 Set 2-Load 9
Slump-41/2" Slump-31/2"
Air temperature—40F Air temperature—44F
Concrete temperature—65F Concrete temperature—63F
John Baugus (CCC)was advised of the on-site test results.
To the best of our knowledge, the work inspected was in accordance with plans dated
12-19-12 and applicable workmanship provisions of the I.B.C., except if noted above.
Reviewed By:
Michael L. Me er
Technical Manager
C:
Chambers Construction Co. —Brian Erickson (email)
Chambers Construction Co.—Jack Makarchek(email)
Robertson Sherwood Architects—Scott Stolarczyk (email)
City of Springfield
MLM:sr
This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific
process and/or material evaluated. As such,information contained herein shall not be reproduced in part or full and/or any part
thereof be disclosed without FEI Testing 8 Inspection,Inc.'s written authorization.
750 NW Come&Avente CavaSS;Oregon97330'phone(541)7574698-fax(541)757-2991
29540 B Airport Road•Eugene,Orecgon 97402•phone(541)6843849•fax(541)684-3851
62979 NE Plateau Drive,Suite 3 Bend,Oregon 97701 •phone(541)382-4844•fax(541)382-4846