HomeMy WebLinkAboutPermit Septic Tank 2001-4-26 .~~..~' ...oum '. ' I ~1~~ ''.' Public \\brill APPLICANT'S COpy SEPTIC INSTALL~.c\TION PERMIT, SP017112. f~. 0106 ~unty Parcels: 17-03-23-34-04400 Site: HA YDEN BRIDGE TO 3RD HOUSE ON 3RD & BLAC 2615 3RD ST SPR Applicant: SMITH BONNIE SUE & TRACY R SMITH BONNIE SUE & TRACY R 2615 N 3RD ST SPRINGFIELD OR 974-77 Owner: !.',;f 2615 N 3RD ST SPRINGFIELD OR 97477 Site Inspection Number: Work Description: REPAIR EXISTING SEPTIC SYSTEM System Type: REPRMJR , SEEP Applied Date: 04/17/2001 Approved Date: 04/26/2001 Issued Date: 05/02/2001 ExpirationDate: 05/02/2002 INSTALLATION REOUIREMENTS: Projected Daily Flow: 525 gallons Drainfield Size: 250 feet' Special Conditions: See attached effluent sewer drop . requirement. . 36"min. 42" max. trench depth ( . 24" gravel below perf. pipe. 30" total Septic Tank Size: 1500 gallons Maximum Depth of Drain field: 42 in. Install as per plan. All DEQ set backs and rules apply. SANITATION SETBACK REOUIREMENTS: From drainfield to property lines and structures: 10 feet From drainfield to well: 100 feet From septic tank to property lines and structures: 5 feet From septic tank to well: 50 feet . .C?44- / Autlionzed,DEQAgent, Date This permit will excire after one year unless the svstem has been insoected. To obtain an inspection, make a drawing of the system as installed on the form provided. Submit the complete form to this office and the inspection will be scheduled. Final insDection for sewaee systems cannot be reauested bv teleDhone~ LANE COUNTY ON-SITE-SEW AGE OFFICE 125 E 8TH Avenue, Eugene OR 97401. PH: (541) 682~3754. Fax: (541) 682-3947 04/26/2001