Loading...
HomeMy WebLinkAboutPermit Building 1993-8-24 . J....~ ~ . , ,~ RESIDENTIAL PERMIT APPLICATION Inspections: 726-3769 Office: 726.3759 LOCATION OF PROPOSED WORK: ASSESSORS MAP: LOT: ~b OWN '\ HE AND i CONSTRUCTION,INC 8495'3 Par kway PLEASANT HILL,OR_97455 ADD! CITV] , DESCRIBE WORK: Sf 0 NEW ../ REMODEL ADDITION (.- OUAD , I MarshaUs Oil & Ins. II OF B I OCCV ( , I Brooks Excavation II OF S I WATER~H't::'f-\-I-C'n, ____ ,,-- SPRINGFIELD .~~; d()9/1 f>l'lM~O Lt1.1l.L.- BLOCK: #71158 I 1 I iATE: DEMOLISH OTHER rhUf}L, J;).f5:) 13cnn~' JOB NUMBERq,'~lI,/ J ...... 225 Fifth Street Springfield, Oregon 97477 TAX LOT: SUBDIVISION: rLu: 6l.SL PaJ\.k_ PHON ",. 7alo B~9g " ZIP' CONST. CONTRACTOR /I 500 Greenfield Eugene, Or 97404 4131"E"St. 25790 Springfield, Or 9 7 4 7 8 27661,Crow Rd Eugene, Or 97402 CONTRACIOR'S_J--!j\ME ____ __ ADDRESS GENER: HE and i Const.,Inc:---a-4959 parkw-ay- -- -- ------- ---- i 1 71158 PLUMBi Peasant H,ill, Or 97455 MECH1 Bills Electric 3170 VI 11th, ELECT1 Eugene, Or 97402 Don Lewis Plumbing EXPI RES - -PRONE 02/95 726-3898 21351 04/94 687-1851 33076 06/93 688-1931 12/93 747-7445 55921 03/94 345-7564 REQUIRED INSPECTIONS & Rough Mechanical - Prior to ~ cove~ . , M"Rough Electrical - Prior to ~ cove~ r I~ Electrical Service - Must be '/ apP,roved to obtain permane'nt electrical power. - D j=ireplace - Prior to faclhg , , rnaterials and framing Insp. .,~ Framing - Prior to cove~ mWall/Ceiling Insulati9n - Prior to {cover. ~,DrYWall - Prior to taping. I i V..'eod piove-:- A~ter ;ns~an;;'li(lr1. CJ Insert - Alter fireplace approval ; and installation of unit. ~urbcut & Approach. -- After " ,,' , for,n1s are erected bulpri"or to 'I placement of concrete. I N- Sidewalk & Driveway .-. After L~xcavatlon is complete, forms '~lnd sub-base material in place. o F~rice "":'" When completed. , ~vStre,:-t Trees -,When all required ~ tree" are planted. To request an inspection, you must call 726-3769. This is a 24 hour recording. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m, will be made the following work day. ~Final Plumbing - When all T plumbing work is complete. r'ltl Final Electrical - When all. ',-- ~electrical work is complete. '-.~~.. ," " rX,cl".Final Mechanical - When all p in~ch~nical worl< is complete. 1kJ Final Building'~ When all , required inspectionshave'been approved and building is completed. D Other MOBILE HOME INSPECTIONS D Blocking and Set-Up - vVh~n all blocking is complete. [J Plumbing Connections - When home has been connected to water and sewer. D Temporary Electric D Site Inspection - To be made after excavation, t)ut' prior to setting forms, o Underslab Plumbing/Electrical! Mechanical - Prior to cover. ~ Footing, - After trenches are excavated, D Masonry - Steel location: bond' beams, grputing. ' " d Foundation - After forms are ~ erected tJut prior to concrete placement. o 121 Underground Plumbing - Prior to filling trencll. Undelfloor Plumbingl Mechanical _ Prior to insulation or deckin~;l. f"\:/rpost and Beam' - Prior to floor ':/\ insulation or decl<ing. ' I 'VI Floor lnsu'lation -:-: Prior to 7" decking, \:vrSanitary Sewer - Prior to filling ~ trencll. , - ' lVt Storm Sewer - Prior to filling ~ trcnct1. ~ Water Line - Prior to filling ~ trencll. ~ Rough Plumbing -, PriO~'t~ ~ cover, ' o Electrical Connection T When blocking, set-up, and plumbing , inspections have been approved and the home is connected to ' the service panel. [-J Final - After all required - inspections are approved and porches, skirting, decl<s, and venting ha~e been installed. Lot faces Lot ,sq. ftg. Lot coverage Topography ]81 Total height BUILDING PERMIT ITEM SO. FT.:, \~qD 4A~ Main Garage Carport Total Value Building permiti=ee State Surcharge Total Fee Lot Type X Interior Corner Panhandle Cul.de'sac ,.~~ Setbacks I P.L.. HSEI GAR ACe IN 'I IS W E x ~,'.go = 2)~A\\B ' \ 4. \ () io~~S- (A) e41~\' , <~?i3ro , \C\ .~O ~fl~D SYSTEMS DEVELOPMENT CHARGE (SDC) , . ", (B) A{)2f5.1'7 PLUMBING PERMIT ITEM j. Fixtures Residential Bath(s) Sanitary Sewer Water Storm Sewer Mobile Home Plumbing Permit State Surcharge Total Charge MECHANICAL PERMIT Furnace Exhaust Hood Vent Fan NO ~ FT. FT. FT. NO (C) ~; Wood Stove/Insert/Fireplace Unit Dryer Vent Mechanical Permit Issuance' . State Surcharge Total Permit '(D) MISCELLANEOUS PERMITS Mobile Home State Issuance State Surcharge' 'Sidewalk ~ft 2iJft Curbcut Demolition ~te SUrC~,rge oD. -\l\() f\ (\Y ~ ~ ,- - . - FEE \loD,oO llo.O ' ro '8.CO l~B,c.o <:l'~ (O;. ci) <=taCO I" ", ',' '" ~,_OU J\~'\~ .\ n.W' 1.\3 '33 '. 1I2 ':) \q,CG '\4 .8:) 41) .00 Total Miscellaneous Permits (E) . ' ,J I" TOTAL AMOUNT DUE (excluding electricaljd'7 J ).'70 (A, B, C, D, and E Combined) IS THE PROPOSED WORK IN THE 'HISTORICAL DISTRICT, OR ON THE HISTORICAL REGISTER? If yes, this application must be signed and approved by the Historical Coordinator prior to permit issuance, APPROVED: BUILDING VALUE, PLAN CHECK AND BUILDING PERMIT This permit is grar)t,ed on the express condition that the "aid construction shall, in ali respects, conform to the Ordinance adopted by the Cit)1 of Springfield, including' the Development Code, regulating the construction ancJ use of buildings, and 'may be suspended or revoked at any time' upcnc violation of any provisions of said ordi.nances, Plan Check Fee 'Jl~. Date Paid' ~ Recel pt N u m be{?~ ~ Rt\:~' ;~ 1-t \ p~~viewec:J try - W. - !6Rlj'~3' Date Systems Development Charge is due on all undeveloped propertieswilhin the City limits which are being improved, ADDITIONAL COMMENl:S., -n \ ,'r.-Tr"\r '-;-^\\~---' lrtJ ~~;;-r' tv - \ .CwuuDUJJL/i)/ f~ ,.1 . - , ,~ Uf' , -~T~\\X\b:\)" ~,tvU _ _' cJ n' 'f\V\; \ l,~-~ ~ \J\QX uITU) '\ l\f\S' . .: - -- 'J." " , '.,.'j.: ,!,';if l:j"i! By signature; I stato and agree, that I havecarefully'examined the completed application and do hereby certify that all information hereon is t"i'iJfJ and correct, and I further certify that a'ny and all work perin/mod shall be done in accordance If~iththe Ordinances C?f IheCity QI SpringfieId, and the Laws oi'the State of Oreg'on PE!rtaining to the work described h,e~ein, and that NO OCCUPANCY will be made of any structure without permission of the Building Safety Division, I furttll:\rcertify that only contractors and employees who are in compli"~nce with ORS 701,055 will be used on this project. I further agr,ee to ensure that all required inspectiol\s are. i'eques \8rj at the prope:- ti rn.~;, that each add ress is readabl e from the 3treet, ,d'lat the permit card is located at the front of the property, and the approve,d ~et of plans will remain , on the site at all times during construction, Signature ~/)ry,~ Date 8-q -q3 ~:~:,:~O:~MBER' ~ )~~ \\)\)h'2j DATE PAIDB.M"~C\'~ .' AMOWNi-REC~vD~ ~,' ,.<16 RECEIVED BY ~ J..... ---./ JOB NO. cr 3 I \ J r CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE WORKSHEET (COMMERCIAL & RESIDENTIAL) NAME OR COMPANY: 1-trE. d c..otJST. TNC. I LOCATION: 20 ~ 7 BONN I ~ LI+1JE::.. DEVELOPMENT TYPE: LOJ2.. - tJE!:-W Sp.fZ.. BUILDING SIZE: 1. STORM DRAINAGE LOT Z,b Nr c.cL..E: ff':... LOT SIZE SQ. Ft. IMPERVIOUS SQ. FT. _ 1---I~? X $0.203 PER SQ. FT. (;(J4~ ) "'- ~ 2. SANITARY SEWER-CITY NO. OF PFU'S 1<1 X $42.08 PER PFU ~57iI) (See Reverse) '- .-/' 3. TRANSPORTATION NO OF UNITS X TRIP RATE X COST PER TRIP X 4. SANITARY SEWER-MWMC NO. OF PFU'S leg x $15.125 PER PFU + $10 MWMC ADM FEE $ 2~-Z 'Z-~ (Use PFU Total From Item 2 Above) MWMCCREDIT IF APPLICABLE (SEE REVERSE) $ '3'f~ TOTAL -MWMC SDC C-z of?' ~ SUBTOTAL (ADD ITEMS 1,2,3 & 4) $ I Cf ? B'~ X $424.31 ~~8~ $ $ / X l.oJ X $424.31 X X $424.31 5. ADMINISTRATIVE FEES BASE CHARGE (SUBTOTAL ABOVE) X .05 ~ ~Lt.k- g ~o 19~ U Kip Burdick I I SOC Coordinator ~ Cf~ €) '-- ~ II TOTAL SDC $ "2.0";5- FIXTURE UNIT,CALCULA-. .IN TABLE: Number of New Fixtures ^ . . lit Equivalent = Fixture Units (N6Te,~ "''J: For remodels, cafcul!lte only the NET additional fixtures) FIXTURE TYPE NUMBER OF NEW FIXTURES UNIT FIXTURE EOUIVALENT UNITS -z. 2 1 2 3 6 2 6 6 1 3 2 1 jHead 2 2 1 6 4 t.f- Bathtub....._..., ,...,..--...,.....,.....,........"...'.. ,."..,........,.,. Drinking Fountain............ ..............,..... ........ ,............ Floor Drain....... ...........................,....".,..............,...... Interceptors For GreasejOiljSolldsjEtc................. Interceptors For Sandj Auto WashjEtc...............,.. laundry Tub /Ootheswasher........ ..............., ........... Ootheswa~er - ;3 Or More.;........:.......................... Mobile Home Park Trap (1 Per Trailer)'.................. . Receptor F9r Refrigerator fWater Station jEte........ Receptor For Commercial SinkjDishwasher jEte.. Shower, Single .StaIL.........,.......... ..... .......... ............ ,Shower, Gang.......,................. ..., ........ ........, ...... ':...,. Sink, Bar, CommerciaL.............. .... ,....... ........ ........ Urinal, Stall fWall.............. ...... ......,..... ....... ..........,..... Wash Basin/Lavatory, Single.......................:.......... . Water Ooset, Public Installation............................. Water Ooset, Private..... ....... ........... ,........ ..,............ Miscellaneous: -z , ( ,2, 7. Z- Z. i TOTAL FIXTURE UNITS /<1, CREDIT CALCULATION TABLE: calculate credits separates. I Based on assessed value. If improvements occurred after annexation date in table, Year Annexed Rate per $1,000 Assessed Value Year Annexed Rate per $1,000 Assessed Value 1979 or before , 1980 1981 1982 1983 1984 '1985 $3.21 3.13 3.08 2.96 2.82 2.68- 2.51 1986 1987 1988 1989 1990 1991 1992 $ 2.24 1.93 1.57 1.18 0.79 '0.44 0.28 Improvement (If after annexation date) ?1.2-1 X $,/tJ.G. ?7c.f()~ (Rate X Assessed Value) X $ = (Rate ,x Assessed Value) CREDIT TOTAL = $ 3tf ~ Credit for Parcel or Land Only If Applicable RUNOFF COEFFICIENTS FOR-STORM DRAINAGE R esid ential.......... ....,...................... .......... .......... 0.4 COmmercial...... .......... ..... ...................... ........... 0.9 I nd ustrial.. ......... ........ ..... ......... .... .....,........ ........ 0.45 Govemmental......................... .......................... 0.5 IMPERVIOUS AREA = TOTAL LOT SIZE X RUNOFF COEFFICIENT