Loading...
HomeMy WebLinkAboutSpecial Inspection Field Test & Inspection Report 1992-3-6 MORTIER ENGINEERING, P.C. STRUCTURAL BUILDING DESIGN. FIRE PROTECTION CODE CONSULTANT. PLAN CHECKING CONSTRUCTION INSPECTION P,Q. BOX 139 . 474 WILLAMETTE STREET EUGENE, OREGON 97440 PHONE (503) 484-9080 . FAX (503) 484.6859 Clifford Esler 1495 Barber Dr. Eugene, OR 97405 March 6, 1992 -( C) SO RE: ..e..9-1;~&=Bluebell - Sorinafield. OR - Excavation & Fill Insoection - w.O. #5526-RDR As you requested, an inspection has been made during the performance of the excavation and placement of gravel fill on this site in preparation for the construction of foundations. The excavation involved removal of surface organic soil and other unsuitable material and the placement of 12" minimum of 1 1/2" minus crushed rock ,.in accordance with our standard procedures. The compacted surface of the crushed rock is adequate for a foundation bearing capacity of 1500 psf which is adequate to support the proposed conventional wood frame residence. The surface of the gravel fill is considered stable soil and therefore, Oregon One and Two Family Dwelling Specialty Code Table No. R-304. 3a would apply in accordance with Section R- 304.3#1. I hope you find this report adequate for your purposes at this time. Please contact me if you have further questions. Thank you for this opportunity to be of service. Very truly yours, ,,/ Emile Mortier, F.E. ECM/rc