HomeMy WebLinkAboutPermit Plumbing 1983-1-20
."'" -
,..""
.~. ....... w.. ""'-~~..,..._._...... ... ,....., .:-....'R:.ES.IO.i'l:A"""C:: ..,.,_.,~. .......u."~'"....._"",.~... '" '-'~ece;:p7; ,,#
t
t
J
1
!
,......., .... ,.",~.._.,.. ",_'~...,... ..... "".. _..."". ",. ....". .. .,,', .~... ,....._'"".. . .~...,," .. ,,,. . .""."",.""." ".....J
APPLICATION/PERMIT
225 North 5th Street
Springfield, Oregon 97477
Building Division
726-3753' .
',J,
Job Location: &12') ~~'U..
Assessors Map N " 07--- 35 ~3
SUbdivision:
/A~.u(/
Tez: Lot NO nL\ t tf).~
- ..:... ~
OI..mer: /Oll/J /-bVtjU5 ()/Z....
Address: &9.ff 6~Lf'ML4- LJay
City:. J}t'~qA-L'c/ (},e
I; I Ne/d
I I : Addi tien
I Remodel
I 'Uobile Home
Phone: 7~ 1 92 7~
zip: 97~;Z 7-
Describe [';orlc
;;d.0r #Of /J/cvkr ~~/7'1
Date of Applicaticn
Contractors
j, L{) .fj
Value ...3 :..,00tJ
Add.~ess
Geneml .:z-/V~,et0c.sr T/V..svCA77tJ/Y'J~L. S#'ELLEy'
PlUmbing G~;O~ ~~~;6h-?t7
Electrical :2JJ. r~U J
Mechar:icd if
Construction Lender
0()~DO
)
---
Signed:
Date:
C!ut~
I -rl,() -K 3
Lisc.#
Er;:;ires
Phcne
7~/-.z()3 ()
"C tf~3 7-
7-1'-</
It is the responsibility of the permit hcZ-der to see that ail.. inspections are made at the proper tim€, that ecch .::.ddress is rer."'o;,ze
from thest1,eet, and that< the permit caxod is located at the front of the property.
*Bui!di~4 Division approved plan shall remain on the Building Site at all times.
PROCEDURE FOR INSPECTION REQUEST:CALL 726-3769 {recorder} stat<e your City designat<ed job nwober, job adC.ress, type of inzpec::icn
requested a~d /dhen you will be ready for inspection, Contractors or Owners ncme and phone number. Requests r~ceived before 7:00 ~
-.,.>ilLbe made th€ same day, requests made after 7:00 am uJiZZ be made the next :JOrkil"{j day.
Reouil"ed InsDecticns
O . SITE INSPECTION: To be made aft<er
: excavat<ion, but prier tc set up of
forms.
O . UNDERSLAB PLUMBING. ELECTRICAL &
NECRA-SICAL: To be made before any
/dork is covered.
0', FOOTING & FOUNDATION: To be made
: after trenches.are excavated and
forms are erected, but< prior to
pouring concrete.
o
UNDSRGROUND PLUHBING. SSWER. W.1TER,
DRAINAGE: To be made prior to fil-
Zir.{J trenches.
D.
o
UNDERFWOR PWMBING & MECHANICAL:
To be made prior to inztallation of
floor insulation or decking.
POST AND BEAM: To be made prior to
, installatien of floor insulation or
decking.
ROUGH PLUI!BING. ELECTRICAL & MECH-
ANICAL: No work is to be covered
,until these insoections have been
made and approved.
FIREPLACE: Prior.to plc.air.{J facing
materials and before framing inspec-
tion.
D FRAJ.!ING: Must be requested after
. approval of rough plumbing, eZectri-
.001.:& mechanical. AU roofi7'.{J
bracing & chimneys, etc. ~~st be
; conroleted. No /dark is to be con-
.,cec.'led until this insvection has
.. b€en made and approlJed.
D
D
"
W; FINAL PLUMBING
0' : FINAL MECHANICAL
lRj". FINAL ELECTRICAL
[J
Your City. pesigr~ted Job Numb€r Is:
D
INSULATION/VAPOR BARRIER INSPECTION:
To be made after all insulation ~d
required vapor carriers are in place
but before any lath, gypswn board or
wall covering is applied, and before
any insulation is concealed.
g3Od80
DEMOLITION OR !,JOVED BUILDIi'JGS
=:J Sanitary $e'.Jer capped =.t p~opert;; lir:.e
==:J Septic tank p~~ed and filled with ;ra~el
I Final - [{hen above ite:-ns are completed
~ and /dhen demolition is complete or st~~c-
tur. ",0"'" w~ ,r='", d,='" up. I
1
Nobile Hemes
~ Blocking
~ Plumbing
~ Electrical Connection - Blocking, set-u~
---l and plumbing connections ~~st ce apprQv~d
before requesting eZec~rical inspec::ion
and Set-up
connections
s;;wer ard wc.ter
~
DRYWALL INSPECTION: To be made
after aZZ dry/daZZ is in place,
but< prior to any taping.
::=J Accesso!'y Building
~
Final - Aft<er perches, skirting,
etc. are completed.
decks~
o
M~ASONRY: Steel Zocation, bond
beamz, grouting or verticals in
accordance 1dith U.B.C. Section
2415.
D
All project conditions, such as the installation of street trees, co:-npletion of tne
required landscaping, etc., must be satisfied before the BUILDING FINAL can be request~d.
/"YPINAL BUILDING: The Final Building Inspection must be requested after the Final Plumbing
~W Electrical, and Mechar:..ical Inspections have been made and approved.
D
WOODSTOVE:
aomplet<ed.
After installation is
'ALL MANHOLES AND CLEANOUTS MUST BE ACCESSIBLE, ADJUST!fENT TO BE n1DE fIT NO CJST TO CI'I'Y P:1qe of 2
D
CURB & .4PPFlOACH APRON: After forms
are erected but prior to pouring
concrete.
SIDEWALK & DRn'EWAY: For all con-
crete paving /dithin street right-
of-way, to be made after all exca-
vating complete & fom 1dOrk & sUb-
base material in place.
D
D
PENCE: ~'hen conrol6te -- Provide.
gates or movable' sections through
P.U.E. .
o
I JOB' N0.g307~Co
Izone: .
Lot Sq. Ftg.
% of lot< Coverage
#- of Stor>ies
Total Height
Topography
ITEM
I Main
SQ.FTG
Garaae
Carport
I
,4ccessor7.i
S.D.C.
TOTAL VALUE
(vatue)
1.5 x
Building Permit
State Surcharge
Total Ch.arges
I ITEM I NO:
I Fixtures
IResidential (1 bath)
Sanitary Seider
Water
l$rir&J dfd-.
.'Y~L~
r Plumbing Pe~t
State Surcharge
Total Charaes
j'iTEM --, ..--,,--. -.".. .,VO'~ ..
I Res. Sa. No.
N8W/Erlend Circuits
Temporary Service
d N' j .511/ r:ur-
Electrical Permit
State Surch.arqe
Total Charc;es
lITEM
Furnace ETU' S
E=haust Hood
Vent Fan
I .
I Woodstove
,
Permit Issuance
Mechanical Permit
State Surcharae
Total Ch.araes
-- ENCROACHMENT
iSe~drit<Y Deposit<
Storage
I Maintenance
I Pe.."'mi t
Total Charaes
I ;;;;'b~t
I Sideldalk
I Fence
I Electrica l
I Mobile Home
Label
TOTAL AMOUNT DUE: *
SOLAR
Occupancl.f Grou'O:
LOT TYPE
x
FEE
. ~ I
I
FEE'
NO..
FSE l
I
I
I
I
I
I
I
I
I
C E S S R EQ.-
Interior
Corner
Panhandle
Cul-de-sac
Value
I
I *
I
5.00 I
,2-0 I
~UJ *
CHARGE "j-
'\
I
I
5. DO I
c::, . tXl
.lb
s.2,OI *
C{[ARGE'-~.'.'-"".' ....'.
J
I
JD.onl
IIJ 00 I
. SiO I
10. t/L) I *
CHARGE
,
I
I
I
-.$ &0.80
Page 2
'''-
T'ipe/Const:
.
\
Bedrooms:
L - C 0 G~
I Lot Faces -
I Setbacks
I P.L. House Carage
INort<h
lEast
South
West
II
i I
I I
I I
I I
II
:1 I
Enerq1.j Sources
Heat
Water' Heater
Range
Pireplace
Woodztove
Ti./De
fl.ccess.
-- Pees
Building Value & Permit
This permit is granted on the express condition that the sdid.construction
shall, in aZl respects, conform to the Ordinance adopted by the City of
Springfield, inaZuding the Zoning Crd-:nance, regulc.ting. the construction
and use of buildi~4S, and may be suspended .or revokec at any time upon vio-
lation of any provisions of said Ordir.ances.
Plan Check Pee:
Date Paid:
Receipt #:
Signed:
Plumbing Permit
No person shaZZ construct, instaU, alter .or change any ne/d or e:::isting
plumbing or drainage systen .in /dhole or in part, unless such person is the
legal possessor of a valid plumber's license, except that a person may do
plumbing work to property /dhich is owned, leased or operated by the appli-
,cCI[Lt.
\. -
Electrica I
Permi t
Where State Laid requiresth.at the electrical work be done by an EleC)trical
Cont<ractoI', the electrical portion of thia permit shaZZ not be valid until
the label has been signed by the Electrical Contractor.
Mechanical Permit
Plan Examiner
Uar;e
I
I
,
I HAVE CAREFULLY EXiLI.fINED t,w completed applicat<ion for permit, and do
hereby certify that all information hereon is true a~4 correct, and I
f~ther certify that< any ar4 all work performed sh.all be done in accor-
dance with the Ordinances of the City of Springfield, and tha L~~s of the
* State of Oregon pertaining to the /dork described herein, and that NO OCCU-
PANCY /dill be made of any structure without permission of the BuiZding Di-
vision. I furtherC)ertify that only C)ontractors a7d ~~loyees who are in
cD~pliance /dith CRS 701.055 /dill be used on this project
g~
M //~~ /L./P-V'-
* YYgned .
,A ;. Zo. g'S
Date